DOI QR코드

DOI QR Code

Medical Contents Visualization System for Smart Device

스마트 기기용 의료 콘텐츠를 위한 영상 가시화 시스템

  • 권구주 (인하대학교 컴퓨터정보공학부) ;
  • 강동수 (인하대학교 컴퓨터정보공학부) ;
  • 고영인 (삼성종합기술원) ;
  • 신병석 (인하대학교 컴퓨터정보공학부)
  • Received : 2012.06.28
  • Accepted : 2012.09.06
  • Published : 2012.10.31

Abstract

Three-dimensional volume rendering method which shows the inside of human body is widely used in medical imaging area. Existing medical imaging system using a volume rendering method already has provided a variety of three-dimensional results. Recently existing results in the medical imaging among physicians and patients to facilitate communication have been studied since smart device which has advantage of portability applied in the medical imaging. In this paper, we propose 3D volume visualization system for a relatively low spec portable smart devices by using 2D textures and we also implements 2D diagnostic images of portable medical imaging visualization system.

3차원 볼륨렌더링 방법은 인체의 외형뿐만 아니라 내부의 모습도 투과하여 보여줄 수 있기 때문에 의료영상 분야에서 널리 사용된다. 기존의 의료영상 장비는 볼륨렌더링 방법을 이용하여 다양한 3차원 영상을 제공하고 있다. 최근 의료영상 분야에서는 휴대성의 장점을 가진 스마트 기기를 도입함으로써 기존 의료영상 분야의 결과물을 의사와 환자들 사이에서 소통이 원활하게 하려는 연구가 활발히 진행되고 있다. 본 논문에서는 비교적 저 사양인 휴대용 스마트 기기에서 3차원 볼륨데이터를 가시화하기 위하여 2차원 텍스쳐를 활용하는 방법을 제안하고 다양한 2차원, 3차원 진단영상을 제공하는 휴대용 의료영상 가시화 시스템을 제안한다.

Keywords

References

  1. K. Engel, M. Hadwiger, J. Kniss, C. Rezk- Salama, and D. Weiskopf, "Real-time Volume Graphics," ACM SIGGRAPH 2004 Course Notes, No. 29, pp. 24-36, 2004.
  2. J. Kruger, R. Westermann, "Acceleration Techniques for GPU-based Volume Rendering," Proceedings of the 14th IEEE Visualization '03, pp. 287-292, 2003.
  3. 계희원, 김준호, "GPGPU 환경에서 최대휘소투영 렌더링의 고속화 방법," 멀티미디어학회논문지, 제14권, 제8호, pp. 981-991, 2011.
  4. 강동수, 신병석, "포인트 프리미티브를 이용한 실시간 볼륨 렌더링 기법," 멀티미디어학회논문지, 제14권, 제10호, pp. 1229-1237, 2011.
  5. F. Lamberti and A. Sanna, "A Streaming-Based Solution for Remote Visualization of 3D Graphics on Mobile Devices," IEEE Transactions on Visualization and Computer Graphics, Vol. 13, No. 2, pp. 247-260, 2007. https://doi.org/10.1109/TVCG.2007.29
  6. K.-L. Ma and D. Camp, "High Performance Visualization of Time-varying Volume Data Over a Wide-area Network," Proc. Supercomputing, ACM/IEEE 2000 Conference, pp. 29-29, 2000.
  7. S. Stegmaier, M. Magallon, and T. Ertl, "A Gerneric Solution for Hardware-accelerated Remote Visualization," Joint EUROGRAPHICS - IEEE TCVG Symposium on Visualization 2002, pp. 87-92, 2002.
  8. N. Tolia, D.G. Andersen, and M. Satyanarayanan, "Quantifying Interactive User Experience on Thin Clients," Computer, Vol. 39, No. 3, pp. 46-52, 2006.
  9. J. Huang, B. Bue, A. Pattath, D. S. Ebert, and K.M. Thomas, "Interactive Illustrative Rendering on Mobile Devices," IEEE Computer Graphics and Applications, Vol. 27, No. 3, pp. 48-56, 2007.
  10. M. Moser and D. Weiskopf, "Interactive Volume Rendering on Mobile Devices," In Workshop on Vision, Modelling, and Visualization VMV '08, pp. 217-226, 2008.
  11. http://www.w3.org/2001/di/. (W3C Ubiquitous Web domain, Device Independence 2001)
  12. http://www.opengles.org. (OpenGL ES, 2007)
  13. J. Kuo, G.R. Bredthauer, J.B. Castellucci, O.T. Von Ramm, "Interactive Volume Rendering of Real-time Three-dimensional Ultrasound Images," IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Vol. 54, No. 2, pp. 313-318, 2007. https://doi.org/10.1109/TUFFC.2007.245
  14. S. Röttger, S. Guthe, D. Weiskopf, T. Ertl, and W. Strasser, "Smart Hardware-accelerated Volume Rendering," Proc. of the Symposium on Data Visualization ′03, pp. 231- 238, 2003.
  15. H. Scharsach, "Advanced GPU Raycasting," Proc. of CESCG '05, pp. 69-76, 2005.
  16. K. Kwon, A Study on Acceleration of Rendering using Ultrasound Volume Data, Inha University Ph.D Thesis, 2006.
  17. V. Shamdasani, U. Bae, R. Managuli, and Y. Kim, "Improving the Visualization of 3D Ultrasound Data with 3D Filtering," Proc. of SPIE 2005, Vol. 57 No. 44, pp. 455-461, 2005.
  18. G. Sakas and S. Walter, "Extracting Surfaces from Fuzzy 3D-Ultrasound Data," Proc. of the 22nd Annual Conference on Computer Graphics and Interactive Techniques, pp. 465-474, 1995.
  19. G. Sakas, L.A. Schreyer, and M. Grimm, "Preprocessing and Volume Rendering of 3D Ultrasonic Data," IEEE Computer Graphics and Applications, Vol. 15, No. 4, pp. 47-54, 1995. https://doi.org/10.1109/38.391490
  20. T.R. Nelson and T.T. Elvins, "Visualization of 3D Ultrasound Data," IEEE Computer Graphics and Applications, Vol. 13, No. 6, pp. 50-57, 1993.
  21. S. Lim and B. Shin, "Reliable Space Leaping using Distance Template," Lecture Notes in Computer Science , Vol. 3337, No. ??, pp. 60-66, 2004.
  22. K. Kwon and B. Shin, "Fast Volume Visualization Techniques for Ultrasound Data," Journal of Biomedical Engineering Research, Vol. 27, No. 1, pp. 6-13, 2006.
  23. G. Knittel, "The UltraVis System," Proc. of IEEE Volume Visualization 2000, pp. 71-79, 2000.
  24. A. Fenster, S. Tong, S. Sherebrin, D.B. Downey, and R.N. Rankin, "Three-dimensional Ultrasound Imaging," Proc. of SPIE Medical Imaging, Vol. 2432, pp. 176-184, 1995.
  25. R. Fattal and D. Lischinski, "Variational Classification for Visualization of 3D Ultrasound Data," Proc. of Visualization 2001, pp. 403-410, 2001.