Abstract
In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using strengthening materials (embedded FRP rod, metal fittings) in existing reinforced concrete buildings. Seven reinforced concrete beams comprised of retrofitted embedded FRP rod (BCR series), embedded FRP rod with metal fittings (BCR-AC series), and standard specimen (BSS) were constructed and tested under monotonic loading. Design parameters of test specimens were amount of embedded FRP rod and metal fittings. The test results showed that the maximum load carrying capacity of specimens with embedded FRP rod (BCR series) and embedded FRP rod with metal fittings (BCR-AC series) increased by 21~55% and 21~63%, respectively, in comparison with the standard specimen BSS. BCR series test specimens failed by the adhesion slip and concrete cover separation. BCR-AC series test specimens failed by the adhesion slip due to the confining effect of metal fittings.
이 연구에서는 기존 철근콘크리트 건축물의 구조성능 향상을 위하여 매입형 FRP봉과 보강철물을 보강한 철근콘크리트 보의 구조성능을 평가하기 위하여 실험을 수행하였다. 매입형 FRP봉의 사용량, 보강철물 유무에 따라 총 7개의 실험체를 제작하고 실험을 수행하여 구조성능을 평가하였으며, 이 연구의 실험 결과를 근거로 다음과 같은 결론을 얻었다. 매입형 FRP봉 보강실험체(BCR 시리즈)의 경우 표준실험체(BSS)와 비교하여 21~55% 내력이 증가하였고, 매입형 FRP봉과 보강철물을 보강한 실험체(BCR-AC 시리즈)는 표준실험체(BSS)보다 최대내력이 21~63% 증가하였다. 그리고 매입형 FRP봉으로 보강된 실험체는 부착슬립, 피복분리 형태로 파괴되었으나, 매입형 FRP봉과 보강철물을 보강한 실험체는 보강철물의 구속효과로 부착슬립의 형태로 파괴되었다.