DOI QR코드

DOI QR Code

Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법

  • Oh, Hyeong-Min (Dept. of Electrical & Information Eng., Seoul Nat'l Univ. of Science and Technology) ;
  • Choi, Se-Wan (Dept. of Electrical & Information Eng., Seoul Nat'l Univ. of Science and Technology) ;
  • Kim, Tae-Hee (Doosan Heavy Industries & Construction Co., Ltd.) ;
  • Lee, Gi-Pung (Doosan Heavy Industries & Construction Co., Ltd.) ;
  • Lee, Tae-Won (Doosan Heavy Industries & Construction Co., Ltd.)
  • Received : 2012.01.25
  • Accepted : 2012.05.07
  • Published : 2012.08.20

Abstract

The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

Keywords

References

  1. S. Jung, Y. Bae, T. Yu, S. Choi, H. Kim. "A Low Cost Utility Interactive Inverter for Residential Fuel Cell Generation," IEEE Trans. Power Electron., Vol. 22. pp. 2293-2298, Nov. 2007. https://doi.org/10.1109/TPEL.2007.909191
  2. L. Wang, C. Singh, A. Kusiak, "Guest Editorial: Special Issue on Integration of Intermittent Renewable Energy Resources into Power Grid," IEEE System Journal, Vol. 6. pp. 2-3, March 2012
  3. T. Hwang, K. Kim, B. Kwon, "Control strategy of 600kW E-BOP for molten carbonate fuel cell generation system," ICEMS 2008, pp. 2366-2371, 2008.
  4. G. Shen, D. Xu, X. Yuan, "A Novel Seamless Transfer Control Strategy Based on Voltage Amplitude Regulation for Utility-interconnected Fuel cell Inverters with an LCL-filter," IEEE PESC 2006, pp. 1-6, 2006.
  5. Z. Yao, L. Xiao, Y. Yan, "Seamless Transfer of Single-Phase Grid-Interactive Inverters between Grid-Connected and Stand-Alone Modes," IEEE Trans. Power Electron., Vol. 25, No. 6, pp. 1597-1603, Jun. 2010. https://doi.org/10.1109/TPEL.2009.2039357
  6. J. Kwon, S. Yoon, S. Choi, "Indirect Current Control for Seamless Transfer of Three-Phase Utility Interactive Inverters," IEEE Trans. Power Electron., Vol. 27, No. 2, pp. 773-781, Feb. 2012.
  7. F. D. Mango, M. Liserre, A. Dell'Aquila, A. Pigazo, "Overview of Anti-Islanding Algorithms for PV Systems. Part I:Passive Methods," Power Electronics and Motion Control Conf., pp. 1878-1883, 2006.
  8. IEEE Standard for Interconnecting Distributed Resources With Electric Power Systems, IEEE 1547, 2003.
  9. N. Pogaku, M. Prodanovic, and T. C. Green, "Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid," IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 613-625, Mar. 2007.
  10. R. Tirumala, N. Mohan, and C. Henze, "Seamless transfer of grid-connected PWM inverters between Utility-Interactive and Stand-Alone Modes," IEEE APEC 2002, pp. 1081-1086, 2002.

Cited by

  1. Anti-islanding Detection of Photovoltaic Inverter Based on Negative Sequence Voltage Injection to Grid vol.17, pp.6, 2012, https://doi.org/10.6113/TKPE.2012.17.6.546
  2. A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability vol.19, pp.4, 2014, https://doi.org/10.6113/TKPE.2014.19.4.312
  3. A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System vol.27, pp.11, 2013, https://doi.org/10.5207/JIEIE.2013.27.11.027
  4. Advanced Control of Three-Phase Four-Wire Inverters using Feedback Linearization under Unbalanced and Nonlinear Load Conditions vol.18, pp.4, 2013, https://doi.org/10.6113/TKPE.2013.18.4.333
  5. An Assessment on Voltage and Power Quality in Load Facility during the Islanding of Residential Fuel Cell System vol.62, pp.12, 2013, https://doi.org/10.5370/KIEE.2013.62.12.1792
  6. A Seamless Mode Transfer Scheme for Single Phase Inverter with ESSs vol.18, pp.6, 2013, https://doi.org/10.6113/TKPE.2013.18.6.579