DOI QR코드

DOI QR Code

Preparation of Conductive Nanoweb through Electrospinning Followed by Electroless Silver-Plating and Its Application as Dry-Type Electrode for ECG Measurement

전기방사에 이은 무전해 은도금을 통한 전도성 나노 섬유 웹의 제조와 ECG 측정용 건식 전극으로의 응용

  • Ahn, Yu-Jin (Department of Advanced Polymer and Fiber Materials, Graduate School, Kyung Hee University) ;
  • Yoon, Sun (Department of Advanced Polymer and Fiber Materials, Graduate School, Kyung Hee University) ;
  • Kim, Kap-Jin (Department of Advanced Polymer and Fiber Materials, Graduate School, Kyung Hee University)
  • 안유진 (경희대학교 대학원 고분자.섬유 신소재학과) ;
  • 윤선 (경희대학교 대학원 고분자.섬유 신소재학과) ;
  • 김갑진 (경희대학교 대학원 고분자.섬유 신소재학과)
  • Received : 2012.01.04
  • Accepted : 2012.02.09
  • Published : 2012.02.28

Abstract

In order to prepare a flexible dry-type electrode for electrocadiogram (ECG), conductive poly(vinylidene fluoride) [PVDF] was electrospun and silver-plated electrolessly. The surface morphology and the mechanical and electrical properties of the silver-plated nanowebs prepared under different plating conditions were evaluated. After silverplating, the prepared web was welded ultrasonically in order to improve the conductivity and the rubbing fastness. Dry-type electrodes were fabricated into eyelet shape by using the ultrasonically welded silver-plated PVDF nanoweb, a sponge and a metal eyelet. Then, it was attached to a commercial sports brassiere top. The ECG of the wearer of the top was measured by the newly developed electrodes and the commercial Ag/AgCl gel electrodes while walking and running. The comparison reveals that the silver-plated PVDF nanowebs can be used as an electrode for ECG measurement.

Keywords

References

  1. K. P. Hoffman and R. Ruff, "Flexible Dry Surface-electrodes for ECG Long-term Monitoring", Proceedings of the 29th Annual International Conference of the IEEE EMBS Cite Internationale, Lyon, France, August 23-26, 2007.
  2. A. Searle and L. Kirkup, "A Direct Comparison of Wet, Dry and Insulating Bioelectric Recording Electrodes", Physiol Meas, 2000, 21, 271-283. https://doi.org/10.1088/0967-3334/21/2/307
  3. J. Coosenmans, B. Hermans, and R. Puers, "Integrating Wireless ECG Monitoring in Textiles", Sensor Actuat APhys, 2006, 130-131, 48-53. https://doi.org/10.1016/j.sna.2005.10.052
  4. D. T. Godin, P. A. Parker, and R. N. Scott, "Noise Characteristics of Stainless-steel Surface Electrodes", Med Biol Eng Comput, 1991, 29, 585-590. https://doi.org/10.1007/BF02446089
  5. S. H. Lee, S. M. Jung, C. K. Lee, K. A. Jeong, G. S. Cho, and S. K. Yoo, "Wearable ECG Monitoring System Using Conductive Fabrics and Active Electrodes", Human-Computer Interaction, Part III, HCII 2009, LNCS 5612, 778-783
  6. S. M. Pack and S. S. Jayaraman, "Smart Textile-Based Wearable Biomedical Systems: A Transition Plan for Research to Reality", IEEE Transactions on Information Technology in Biomedicine, 2010, 14, 86-92. https://doi.org/10.1109/TITB.2009.2025817
  7. W. Yu, G. Kai, P. W. Hua, G. Qiang, L. X. Qian, C. H. Da, and Y. J. Hong, "Fabrication of Dry Electrode for Recording Bio-potentials", Chin Phys Lett, 2011, 28, 010701.
  8. S. M. Kim and W. S. Song, "Oxidation Prevention Effect and Physical Properties of Electroless Silver-plated Polyester Fabrics", Text Sci Eng, 2011, 48, 33-41.
  9. S. Q. Jiang, E. Newton, C. W. M. Yuen, and C. W. Kan, "Chemical Silver Plating on Cotton and Polyester Fabrics and Its Application on Fabric Design", Text Res J, 2006, 76, 57-65. https://doi.org/10.1177/0040517506053827
  10. S. Y. Chang, J. H. Lin, S. J. Lin, and T. Z. Kattamis, "Processing Copper and Silver Matrix Composites by Electroless Plating and Hot Pressing", Metall Mater Trans A, 1999, 30A, 1119-1136.
  11. F. L. Huang, Q. Q. Wang, Q. F. Wei, W. D. Gao, H. Y. Shou, and S. D. Jiang, "Dynamic Wettability and Contact Angles of Poly(vinylidene fluoride) Nanofiber Membranes Grafted with Acrylic Acid", Express Polym Lett, 2010, 4, 551-558. https://doi.org/10.3144/expresspolymlett.2010.69
  12. J. S. Kim, E. Y. Kuk, K. N. Yu, J. H. Kim, S. J. Park, H. J. Lee, S. H. Kim, Y. K. Park, Y. H. Park, C. Y. Hwang, Y. K. Kim, Y. S. Lee, D. H. Jeong, and M. H. Cho, "Antimicrobial Effects of Silver Nanoparticles", Nanomed-Nanotechnol, 2007, 3, 95-101. https://doi.org/10.1016/j.nano.2006.12.001
  13. E. S. Kim, S. H. Kim, and C. H. Lee, "Electrospinning of Polylactide Fibers Containing Silver Nanoparticles", Macromol Res, 2010, 18, 215-221. https://doi.org/10.1007/s13233-010-0316-4
  14. B. Gonçalves, G. Guizzardi, and J. G. P. Filho, "An Electrocardiogram (ECG) Domain Ontology II", Workshop on Ontologies and Metamodeling in Software and Data Engineering, WOMSDE 2007, 68-81.
  15. K. Vanisree and S. Jyothi, "Automatic Detection of ECG RR Interval using Discrete Wavelet Transformation", Int J Comput Sci Eng, 2011, 3(4), 1599-1605.

Cited by

  1. A Study of Electrode Locations for Design of ECG Monitoring Smart Clothing based on Body Mapping vol.17, pp.6, 2015, https://doi.org/10.5805/SFTI.2015.17.6.1039
  2. Characteristics of polyurethane nanowebs treated with silver nanowire solutions as strain sensors 2017, https://doi.org/10.1177/0040517517697647
  3. Nanostructured piezoelectric polymers vol.132, pp.13, 2015, https://doi.org/10.1002/app.41667
  4. Physical Activity Monitoring Using PVDF Film-Embedded Elastic Belt vol.49, pp.6, 2012, https://doi.org/10.12772/TSE.2012.49.6.418
  5. Polyurethane nanoweb-based textile sensors treated with single-walled carbon nanotubes and silver nanowire pp.1746-7748, 2018, https://doi.org/10.1177/0040517518805382