참고문헌
- Arce, L., M. Zougagh, C. Arce, A. Moreno, A. Ríos, and M. Valcarcel. 2007. Self assembled monolayer-based piezoelectric flow immunosensor for the determination of canine immunoglobulin. Biosens. Bioelectron. 22: 3217-3223. https://doi.org/10.1016/j.bios.2007.02.014
- Carter, R. M., J. J. Mekalanos, M. B. Jacobs, G. J. Lubrano, and G. G. Guilbault. 1995. Quartz crystal microbalance detection of Vibrio cholerae O139 serotype. J. Immunol. Methods 187: 121-125. https://doi.org/10.1016/0022-1759(95)00176-B
-
Chou, S. F., W. L. Hsu, J. M. Hwang, and C. Y. Chen. 2002. Determination of
${\alpha}$ -fetoprotein in human serum by a quartz crystal microbalance-based immunosensor. Clin. Chem. 48: 913-918. - Choudhary, M. K., R. Agrawal, R. Kumar, P. Singh, B. R. K. Gupta, and K. P. Singh. 2010. Detection of cadmium-resistant rhizobacteria using piezoelectric nanobiosensor. Int. J. Nanosci. 9: 461-469. https://doi.org/10.1142/S0219581X10007034
- Eva, B. L., C. Olivier, J. Fco, and M. F. Xavier. 2008 Gold immuno-functionalisation via self-assembled monolayers: Study of critical parameters and comparative performance for protein and bacteria detection. J. Immunol. Methods 336: 203-212. https://doi.org/10.1016/j.jim.2008.04.017
- Garcia, M. N. V. and M. Toby 2003. Biosensor technology addressing agricultural problems. Biosyst. Eng. 84: 1-12. https://doi.org/10.1016/S1537-5110(02)00236-2
- Gaur, Y. D. 2000. Enzyme linked immuno assay, pp. 135-136. In: Immunological and Molecular Marker Techniques for Ecological Studies of Soil Microorganisms: A Manual Theory and Practice. Winter School (20 Dec. 1999-9 Jan. 2000). I.A.R.I.
- Guo, H. S., L. Luo, X. Chen, Q. Xiao, W. Xi, G. Wei, et al. 2010. Bioremediation of heavy metals by growing hyperaccumulaor endophytic bacterium Bacillus sp. L14. Bioresour. Technol. 101: 8599-8605. https://doi.org/10.1016/j.biortech.2010.06.085
- Hong, S. R. S., J. Choi, H. D. Jeong, and S. Hong. 2009. Development of QCM biosensor to detect a marine derived pathogenic bacteria Edwardsiella tarda using a novel immobilisation method. Biosens. Bioelectron. 24: 1635-1640. https://doi.org/10.1016/j.bios.2008.08.027
- Irem, K. O., H. Avn, and M. Mehmet, 2009. QCM-based DNA biosensor for detection of genetically modified organisms (GMOs). Biochem. Eng. J. 44: 142-150. https://doi.org/10.1016/j.bej.2008.11.011
- Ivnitski, D., I. Abdel-Hamid, P. Atanasov, and E. Wilkins. 1999. Biosensors for detection of pathogenic bacteria. Biosens. Bioelectron. 14: 599-624. https://doi.org/10.1016/S0956-5663(99)00039-1
- Jacobs, M. B. R., M. Cater, G. J. Lubrano, and G. G. Guilbault. 1995. A piezoelectric biosensor for Listeria monocytogenes. Am. Lab. 27: 26-28.
- Kumar, A. 2000. http://www.tms.org/pubs/journals/JOM/0010/Kumar/Kumar-0010.htmc.
- Liu, Y. C. C., M. Wang, and K. P. Hsiung. 2001. Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay. Anal. Biochem. 299: 130-135. https://doi.org/10.1006/abio.2001.5409
- Lopareva, P. A., B. Pourrut, C. Waterlot, G. Garcon, G. Bidar, C. Pruvot, et al. 2011. Assessment of fly ash-aided phytostabilisation of highly contaminated soils after an 8-year field trial: Part 1. Influence on soil parameters and metal extractability. Sci. Total Environ. 409: 647-654. https://doi.org/10.1016/j.scitotenv.2010.10.040
- Marco, M. P. and D. Barcelo. 1996. Environmental applications of analytical biosensors. Meas. Sci. Technol. 7: 1547-1562. https://doi.org/10.1088/0957-0233/7/11/002
- Muramatsu, H., K. Kajiwara, E. Tamiya, and I. Karube. 1986. Piezoelectric immunosensor for the detection of Candida albicans microbes. Anal. Chem. Acta 188: 257-261.
- Olivier, L., C. F. J. Del, and M. F. Xavier. 2007. Pathogen detection: A perspective of traditional methods and biosensors. Biosens. Bioelectron. 22: 1205-1217. https://doi.org/10.1016/j.bios.2006.06.036
- Ozturk, S., B. Aslim, and Z. Suludere. 2010. Cadmium (II) sequestration characteristics by two isolates of Synechocystis sp. in terms of exopolysaccharide (EPS) production and monomer composition. Bioresour Technol. 101: 9742-9748. https://doi.org/10.1016/j.biortech.2010.07.105
- Satlewal, A., R. Soni, M. G. H. Zaidi, Y. Shouche, and R. Goel. 2008. Comparative biodegradation of hdpe and ldpe using an indigenously developed microbial consortium. J. Microbiol. Biotechnol. 18: 477-482.
- Saurbrey, G. 1959. Use of quartz crystal vibrator for weighting thin films on a microbalance. Eur. Phys. J. A Hadrons Nuclei 155: 206-212. https://doi.org/10.1007/BF01337937
- Su, X. D., S. F. Y. Li, J. Kwang, and S. Low. 2000. Piezoelectric quartz crystal based screening test for porcine reproductive and respiratory syndrome virus infection in pigs. Analyst 125: 725-730. https://doi.org/10.1039/a909415f
- Ye, J., S. V. Letcher, and A. G. Rand 1997. Piezoelectric biosensor for detection of Salmonella Typhimurium. J. Food Sci. 62: 1067-1071. https://doi.org/10.1111/j.1365-2621.1997.tb15039.x
피인용 문헌
- Advances in nano-scaled biosensors for biomedical applications vol.138, pp.16, 2012, https://doi.org/10.1039/c3an00438d
- Synergistic Enzyme Cocktail to Enhance Hydrolysis of Steam Exploded Wheat Straw at Pilot Scale vol.6, pp.None, 2012, https://doi.org/10.3389/fenrg.2018.00122
- Rice straw as a feedstock for biofuels: Availability, recalcitrance, and chemical properties vol.12, pp.1, 2012, https://doi.org/10.1002/bbb.1818