Seismic Performance Test of Concrete-filled U-shaped Steel Beam-to-Prefabricated Column Connections

콘크리트 채움 U형 합성보와 선조립기둥의 내진접합부 성능실험

  • Received : 2012.01.03
  • Published : 2012.04.25

Abstract

In this paper, the connection details of the prefabricated RC/SRC columns and a concrete-encased U-shaped steel beam is presented, and their seismic resistance performance is evaluated through a full-scale test. One of the life-scale column specimens for the test is a prefabricated RC column built with reinforcing bars, and the other one is a prefabricated SRC column built with L-shaped angle steels and reinforcing bars. Both of the columns are fully fabricated at factory by precise shop welding, so they don't need on-site bar arrangement and temporary supports. Although there were many other seismic resistance performance evaluation tests with the forenamed columns and beams, but most of the previous tests were mainly arranged to demonstrate the performance of the connections as the special moment frame (SMF). However, in majority of real-world cases special moment frame is generally not common due to high cost and low workability. This paper presents more practical connection details of beam-to-column connections which accord with the intermediate moment frame (IMF) conditions as defined in the Korea Building Code 2009 (KBC2009) and, also, presents the result of the test which proves the aforementioned claim by using the life-scale specimens and finite element analysis.

Keywords

Acknowledgement

Supported by : 중소기업청

References

  1. Leon, R. T.(1998) Composite connections, Structural Enginee ring and Materials, Construction Research Communications, Vol.1, No.2, pp. 159-169.
  2. Xiao, Y., Choo, B. S., and Nethercot, D. A. (1994) Composite Connections in Steel and Concrete.I. Experimental Behavior of Composite Beam-Column Connections, Journal of Const ructional Steel Research, ELSEVIER, Vol. 31, No.1, pp.3-30. https://doi.org/10.1016/0143-974X(94)90021-3
  3. Anderson, D. and Najafi, A. A. (1994) Performance of Composite Connections: Major Axis End Plate Joints, Journal of Constructional Steel Research, ELSEVIER, Vol. 31, No. 1, p p. 31-57. https://doi.org/10.1016/0143-974X(94)90022-1
  4. 내화구조인증서, 제 09-129호, 인증번호: BS09-0928-1a, 한국건설기술연구원장.
  5. 김성배, 함정태, 이창남, 김상섭, SRC 기둥-TSC 보접합부의 거동에 관한 연구, 대한건축학회논문집, 대한건축학회, 제22권, 제6호, pp. 55-62, 2006
  6. 박홍근, 이철호, 박창희, 황현종, 이창남, 김형섭, 김성배, 콘크리트채움 U형 강재보-강재기둥합성 내진접합부에 대한 주기 하중 실험, 한국강구조학회논문집, 한국강구조학회, 제23권 3호, pp. 337-347, 2011
  7. 박창희, 이철호, 박홍근, 황현종, 이창남, 김형섭, 김성배, 콘크리트채움 U형 합성보-H형강기둥 십자형 합성접합부의 내진성능, 한국강구조학회논문집, 한국강구조학회, 제23권 4호, pp. 503-514, 2011
  8. 송진아, 박홍근, 이창남, 엄태성, PRC 보-기둥 접합부의 내진성능, 대한건축학회논문집, 대한건축학회, 2011.10
  9. 황현종, 박홍근, 이철호, 박창희, 이창남, 김형섭, 김성배, 콘크 리트채움 U형 강재보-콘크리트 기둥 접합부의 내진성능, 한국강구조학회논문집, 한국강구조학회, 제23권 1호, pp. 83-97, 2011
  10. 대한건축학회(2010) 건축구조기준 및 해설(KBC2009) 기문당.
  11. ABAQUS/Standard user's manual version 6.5. Pawtucket (RI): Hibbitt, Karlsson & Sorensen, Inc.; 2005.
  12. American Institute of Steel Construction (AISC) (2005) Seismic provisions for structural steel buildings, Chicago.