DOI QR코드

DOI QR Code

Study on the determination of optimum size of storage tank and intercepting capacity for CSOs reduction in urban area

도시지역 CSOs 저감을 위한 저류조 및 이송관로의 최적 용량결정에 관한 연구

  • Received : 2012.08.20
  • Accepted : 2012.10.22
  • Published : 2012.12.15

Abstract

Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity.

Keywords

References

  1. Kong, M.K. , Bae, K.H. and Kang, W.Y. (2004) Optimal Sizing of Intercepting Flow for Reducing Pollution Loads Causes by CSOs , Journal of the Korean Society of Water and Wastewater, 18(4), pp. 418-424
  2. Kim, J .K. and Ko, I.H. (2006) Modeling of Discharge Characteristics of Combined Sewer Overflows (CSOs) from a Small Urban Watershed in Daejeon City, J. of KSEE, 28(6), pp. 654-660
  3. Jo, D. K . and Kim, G.H.(2006) Characterization of Combined Sewer Overflows from a Small Urban Watershed and Determination of Optimum Detention Volume, Journal of Korean Society of Water quality, 22(2), pp. 314-320
  4. Korean Water and Wastewater Association (2011) Design Criteria of Wastewater Treatment
  5. Korea Environment Corporation (2004) Study on the Combined Sewer Oveflows in Urban and Loading of Rainfall Separate Line
  6. Ministry of Environment (2011) Statistics of Wastewater
  7. Ministry of Environment (2010) Study on Upgrading of Combinbed Sewer
  8. Ministry of Environment (2007) Feasibility Study on the Reduction of Combined Sewer Overflows
  9. Deletic, A. (1998) The first flush load of urban surface runoff. Water Resources, 32, pp. 2462-2470
  10. Donigian , Jr., A.S., (2000) HSPF Training Workshop Handbook and CD. Lecture #19. Calibration and Verification Issues, Slide #L19-22. EPA Headquarters, Washington Information Center, 10-14 January, Washington, D.C
  11. Sansalone, J.J., and Buchberger, S.G. (1997) Partitioning and first flush of metals in urban roadway storm water, J. of Environ. Engineering, 123(2), pp. 134-143 https://doi.org/10.1061/(ASCE)0733-9372(1997)123:2(134)
  12. Taebi, A and Droste, R.L. (2004) First flush pollution load of urban stormwater runoff, J. of Environ. Engineering and Science, (3), pp. 301-309
  13. U.S.EPA (1993) Combined Sewer Overflow Control

Cited by

  1. A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time vol.39, pp.5, 2017, https://doi.org/10.4491/KSEE.2017.39.5.277
  2. 3D 프린터를 이용한 회전 버킷이 부착된 저류조의 모형 실험 vol.59, pp.2, 2012, https://doi.org/10.5389/ksae.2017.59.2.049