References
- Baldi S, Mounayer C, Piotin M, Spelle L, Moret J : Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter. AJNR Am J Neuroradiol 24 : 1222-1225, 2003
- Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP : Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms : strategies in stent deployment and midterm follow-up. Neurosurgery 61 : 460-468; discussion 468-469, 2007 https://doi.org/10.1227/01.NEU.0000290890.62201.A9
- Gruber DP, Crone KR : Endoscopic washout : a new technique for treating chronic subdural hematomas in infants. Pediatr Neurosurg 27 : 292-295, 1997 https://doi.org/10.1159/000121273
- Horikoshi T, Fukamachi A, Nishi H, Fukasawa I : Detection of intracranial aneurysms by three-dimensional time-of-flight magnetic resonance angiography. Neuroradiology 36 : 203-207, 1994 https://doi.org/10.1007/BF00588131
- Horowitz M, Levy E, Sauvageau E, Genevro J, Guterman LR, Hanel R, et al. : Intra/extra-aneurysmal stent placement for management of complex and wide-necked-bifurcation aneurysms : eight cases using the waffle cone technique. Neurosurgery 58 : ONS258-ONS262; discussion ONS262, 2006
- Huang Q, Xu Y, Hong B, Zhao R, Zhao W, Liu J : Stent-assisted embolization of wide-neck anterior communicating artery aneurysms : review of 21 consecutive cases. AJNR Am J Neuroradiol 30 : 1502-1506, 2009 https://doi.org/10.3174/ajnr.A1618
- Kelly ME, Turner RD 4th, Moskowitz SI, Gonugunta V, Hussain MS, Fiorella D : Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 29 : 1959-1960, 2008 https://doi.org/10.3174/ajnr.A1224
- Klisch J, Clajus C, Sychra V, Eger C, Strasilla C, Rosahl S, et al. : Coil embolization of anterior circulation aneurysms supported by the Solitaire AB Neurovascular Remodeling Device. Neuroradiology 52 : 349-359, 2010 https://doi.org/10.1007/s00234-009-0568-x
- Moret J, Cognard C, Weill A, Castaings L, Rey A : [Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases]. J Neuroradiol 24 : 30-44, 1997
- Murao K, Yamada N, Miyamoto S, Hyuga T, Kudo T, Satow T : Identification of inflow zone of cerebral aneurysm by MRA for effective coil embolization. Surg Cereb Stroke 36 : 459-463, 2008 https://doi.org/10.2335/scs.36.459
- Perez-Arjona E, Fessler RD : Basilar artery to bilateral posterior cerebral artery 'Y stenting' for endovascular reconstruction of wide-necked basilar apex aneurysms : report of three cases. Neurol Res 26 : 276-281, 2004 https://doi.org/10.1179/016164104225013969
- Pierce DS, Rosero EB, Modrall JG, Adams-Huet B, Valentine RJ, Clagett GP, et al. : Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting. J Vasc Surg 49 : 602-606; discussion 606, 2009 https://doi.org/10.1016/j.jvs.2008.10.016
- Ryu CW, Koh JS, Lee CY, Kim EJ : Endovascular management of the wide-neck aneurysms : the applications of the coils and catheter. Neurointervention 5 : 71-78, 2010 https://doi.org/10.5469/neuroint.2010.5.2.71
- Sychra V, Klisch J, Werner M, Dettenborn C, Petrovitch A, Strasilla C, et al. : Waffle-cone technique with SolitaireTM AB remodeling device : endovascular treatment of highly selected complex cerebral aneurysms. Neuroradiology 53 : 961-972, 2011 https://doi.org/10.1007/s00234-010-0766-6
- Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M : Treatment of wide-necked intracranial aneurysms with a self-expanding stent system : initial clinical experience. AJNR Am J Neuroradiol 24 : 1192-1199, 2003
Cited by
- Waffle‐Cone Technique Using Solitaire AB Stent for Endovascular Treatment of Complex and Wide‐Necked Bifurcation Cerebral Aneurysms vol.24, pp.6, 2014, https://doi.org/10.1111/jon.12121
- Waffle Y technique: pCONus for tandem bifurcation aneurysms of the middle cerebral artery vol.6, pp.10, 2012, https://doi.org/10.1136/neurintsurg-2013-010921.rep
- Hybrid Y Stenting with the Waffle-Cone : A Technical Note vol.20, pp.6, 2012, https://doi.org/10.15274/inr-2014-10065
- Coil Occlusion of Wide-Neck Bifurcation Aneurysms Assisted by a Novel Intra- to Extra-Aneurysmatic Neck-Bridging Device (pCONus): Initial Experience vol.35, pp.5, 2014, https://doi.org/10.3174/ajnr.a3807
- Navigation of Stents across Communicating Arteries for Aneurysm Embolization vol.41, pp.2, 2012, https://doi.org/10.1017/s0317167100016577
- Iatrogenic Carotid-Cavernous Fistula after Stent Assisted Coil Embolization of Posterior Communicating Artery Aneurysm vol.17, pp.1, 2012, https://doi.org/10.7461/jcen.2015.17.1.43
- The effectiveness of the waffle-cone technique in treating complex intracranial aneurysms vol.21, pp.4, 2012, https://doi.org/10.1177/1591019915590529
- Extraction of a migrated coil from the Enterprise stent strut using a Solitaire AB stent vol.29, pp.6, 2016, https://doi.org/10.1177/1971400916666556
- Intra-aneurysmal hemodynamics: evaluation of pCONus and pCANvas bifurcation aneurysm devices using DSA optical flow imaging vol.8, pp.11, 2016, https://doi.org/10.1136/neurintsurg-2015-011927
- Misaligned pCONus Device: Case Report of a Unique Complication vol.7, pp.1, 2012, https://doi.org/10.4103/jcis.jcis_36_17
- Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication vol.7, pp.1, 2017, https://doi.org/10.4103/jcis.jcis_67_17
- The pCONus Device in Treatment of Wide-necked Aneurysms : Technical and Midterm Clinical and Angiographic Results vol.28, pp.1, 2012, https://doi.org/10.1007/s00062-016-0542-z