DOI QR코드

DOI QR Code

Waffle-Cone Technique Using Solitaire AB Stent

  • Park, Hye-Ran (Department of Neurosurgery, Soonchunhyang University Cheonan Hospital) ;
  • Yoon, Seok-Mann (Department of Neurosurgery, Soonchunhyang University Cheonan Hospital) ;
  • Shim, Jai-Joon (Department of Neurosurgery, Soonchunhyang University Cheonan Hospital) ;
  • Kim, Sung-Ho (Department of Neurosurgery, Soonchunhyang University Gumi Hospital)
  • Received : 2011.09.21
  • Accepted : 2012.04.15
  • Published : 2012.04.28

Abstract

The waffle-cone technique is a modified stent application technique, which involves protrusion of the distal portion of a stent into an aneurysm fundus to provide neck support for subsequent coiling. The authors report two cases of wide necked basilar bifurcation aneurysms, which were not amenable to stent assisted coiling, that were treated using the waffle-cone technique with a Solitaire AB stent. A 58-year-old woman presented with severe headache. Brain CT showed subarachnoid hemorrhage and angiography demonstrated a ruptured giant basilar bifurcation aneurysm with broad neck, which was treated with a Solitaire AB stent and coils using the waffle-cone technique. The second case involved an 81-year-old man, who presented with dizziness caused by brain stem infarction. Angiography also demonstrated a large basilar bifurcation unruptured aneurysm with broad neck. Solitaire AB stent deployment using the waffle-cone technique, followed by coiling resulted in near complete obliteration of aneurysm. The waffle-cone technique with a Solitaire AB stent can be a useful alternative to conventional stent application when it is difficult to catheterize bilateral posterior cerebral arteries in patients with a wide-necked basilar bifurcation aneurysm.

Keywords

References

  1. Baldi S, Mounayer C, Piotin M, Spelle L, Moret J : Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter. AJNR Am J Neuroradiol 24 : 1222-1225, 2003
  2. Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP : Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms : strategies in stent deployment and midterm follow-up. Neurosurgery 61 : 460-468; discussion 468-469, 2007 https://doi.org/10.1227/01.NEU.0000290890.62201.A9
  3. Gruber DP, Crone KR : Endoscopic washout : a new technique for treating chronic subdural hematomas in infants. Pediatr Neurosurg 27 : 292-295, 1997 https://doi.org/10.1159/000121273
  4. Horikoshi T, Fukamachi A, Nishi H, Fukasawa I : Detection of intracranial aneurysms by three-dimensional time-of-flight magnetic resonance angiography. Neuroradiology 36 : 203-207, 1994 https://doi.org/10.1007/BF00588131
  5. Horowitz M, Levy E, Sauvageau E, Genevro J, Guterman LR, Hanel R, et al. : Intra/extra-aneurysmal stent placement for management of complex and wide-necked-bifurcation aneurysms : eight cases using the waffle cone technique. Neurosurgery 58 : ONS258-ONS262; discussion ONS262, 2006
  6. Huang Q, Xu Y, Hong B, Zhao R, Zhao W, Liu J : Stent-assisted embolization of wide-neck anterior communicating artery aneurysms : review of 21 consecutive cases. AJNR Am J Neuroradiol 30 : 1502-1506, 2009 https://doi.org/10.3174/ajnr.A1618
  7. Kelly ME, Turner RD 4th, Moskowitz SI, Gonugunta V, Hussain MS, Fiorella D : Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 29 : 1959-1960, 2008 https://doi.org/10.3174/ajnr.A1224
  8. Klisch J, Clajus C, Sychra V, Eger C, Strasilla C, Rosahl S, et al. : Coil embolization of anterior circulation aneurysms supported by the Solitaire AB Neurovascular Remodeling Device. Neuroradiology 52 : 349-359, 2010 https://doi.org/10.1007/s00234-009-0568-x
  9. Moret J, Cognard C, Weill A, Castaings L, Rey A : [Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases]. J Neuroradiol 24 : 30-44, 1997
  10. Murao K, Yamada N, Miyamoto S, Hyuga T, Kudo T, Satow T : Identification of inflow zone of cerebral aneurysm by MRA for effective coil embolization. Surg Cereb Stroke 36 : 459-463, 2008 https://doi.org/10.2335/scs.36.459
  11. Perez-Arjona E, Fessler RD : Basilar artery to bilateral posterior cerebral artery 'Y stenting' for endovascular reconstruction of wide-necked basilar apex aneurysms : report of three cases. Neurol Res 26 : 276-281, 2004 https://doi.org/10.1179/016164104225013969
  12. Pierce DS, Rosero EB, Modrall JG, Adams-Huet B, Valentine RJ, Clagett GP, et al. : Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting. J Vasc Surg 49 : 602-606; discussion 606, 2009 https://doi.org/10.1016/j.jvs.2008.10.016
  13. Ryu CW, Koh JS, Lee CY, Kim EJ : Endovascular management of the wide-neck aneurysms : the applications of the coils and catheter. Neurointervention 5 : 71-78, 2010 https://doi.org/10.5469/neuroint.2010.5.2.71
  14. Sychra V, Klisch J, Werner M, Dettenborn C, Petrovitch A, Strasilla C, et al. : Waffle-cone technique with SolitaireTM AB remodeling device : endovascular treatment of highly selected complex cerebral aneurysms. Neuroradiology 53 : 961-972, 2011 https://doi.org/10.1007/s00234-010-0766-6
  15. Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M : Treatment of wide-necked intracranial aneurysms with a self-expanding stent system : initial clinical experience. AJNR Am J Neuroradiol 24 : 1192-1199, 2003

Cited by

  1. Waffle‐Cone Technique Using Solitaire AB Stent for Endovascular Treatment of Complex and Wide‐Necked Bifurcation Cerebral Aneurysms vol.24, pp.6, 2014, https://doi.org/10.1111/jon.12121
  2. Waffle Y technique: pCONus for tandem bifurcation aneurysms of the middle cerebral artery vol.6, pp.10, 2012, https://doi.org/10.1136/neurintsurg-2013-010921.rep
  3. Hybrid Y Stenting with the Waffle-Cone : A Technical Note vol.20, pp.6, 2012, https://doi.org/10.15274/inr-2014-10065
  4. Coil Occlusion of Wide-Neck Bifurcation Aneurysms Assisted by a Novel Intra- to Extra-Aneurysmatic Neck-Bridging Device (pCONus): Initial Experience vol.35, pp.5, 2014, https://doi.org/10.3174/ajnr.a3807
  5. Navigation of Stents across Communicating Arteries for Aneurysm Embolization vol.41, pp.2, 2012, https://doi.org/10.1017/s0317167100016577
  6. Iatrogenic Carotid-Cavernous Fistula after Stent Assisted Coil Embolization of Posterior Communicating Artery Aneurysm vol.17, pp.1, 2012, https://doi.org/10.7461/jcen.2015.17.1.43
  7. The effectiveness of the waffle-cone technique in treating complex intracranial aneurysms vol.21, pp.4, 2012, https://doi.org/10.1177/1591019915590529
  8. Extraction of a migrated coil from the Enterprise stent strut using a Solitaire AB stent vol.29, pp.6, 2016, https://doi.org/10.1177/1971400916666556
  9. Intra-aneurysmal hemodynamics: evaluation of pCONus and pCANvas bifurcation aneurysm devices using DSA optical flow imaging vol.8, pp.11, 2016, https://doi.org/10.1136/neurintsurg-2015-011927
  10. Misaligned pCONus Device: Case Report of a Unique Complication vol.7, pp.1, 2012, https://doi.org/10.4103/jcis.jcis_36_17
  11. Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication vol.7, pp.1, 2017, https://doi.org/10.4103/jcis.jcis_67_17
  12. The pCONus Device in Treatment of Wide-necked Aneurysms : Technical and Midterm Clinical and Angiographic Results vol.28, pp.1, 2012, https://doi.org/10.1007/s00062-016-0542-z