DOI QR코드

DOI QR Code

Outbreak of Bioaerosols with Continuous Use of Humidifier in Apartment Room

  • Lee, Ji-Hyun (Institute of Nanoproduct Safety Research, Hoseo University) ;
  • Ahn, Kang-Ho (Department of Mechanical Engineering, Hanyang University) ;
  • Yu, Il-Je (Institute of Nanoproduct Safety Research, Hoseo University)
  • Received : 2012.04.03
  • Accepted : 2012.06.26
  • Published : 2012.06.30

Abstract

The effect of continuous humidifier use on the bioaerosol concentration in an indoor environment was investigated. An ultrasonic humidifier was operated for 10 hr per day for 15 days in an apartment room. During this time period, viable bioaerosol samples were taken using a single-stage Andersen sampler containing culture media plates for bacteria and fungi. The culture plates were then incubated at room temperature for 2~7 days depending on the media. The counts for the air sample plates were corrected for multiple impactions using the positive hole conversion method and are reported as the colony forming units per cubic meter of air (CFU/$m^3$). While the bacterial concentration measured using the tryptic soy agar (TSA) did not show any significant change during the first 3 days, the concentration increased from the $6^{th}$ day (6979 CFU/$m^3$) and reached a maximum on the $9^{th}$ day (46431 CFU/$m^3$). The concentration then decreased to 2470 CFU/$m^3$ on the $12^{th}$ day, at which point the fungal concentration increased rapidly to 14424~16038 CFU/$m^3$. Also, while the fungal concentration showed a significant change until the $9^{th}$ day of humidifier use, fungal growth was observed on the wallpaper and increased rapidly from the $12^{th}$ day. However, the bacterial concentration increased rapidly after the fungi were removed by remediation. The major fungal species identified in the samples were Penicillium representing 34%, Aspergillus representing 31%, Cladosporium representing 24%, and Alternaria representing 1%. The results also indicated that a relative humidity over 80% was easily achieved with continuous humidifier use. Yet, maintaining a high humidity in a room can cause a rapid outbreak of microbial growth.

Keywords

References

  1. ACGIH (1999). Bioaerosols assessment and control. American Conference of Governmental Industrial Hygienists. Cincinnati.
  2. Andersen, A.A. (1958). New Sampler for the collection, sizing, and enumeration of viable airborne particles. J. Bacteriol., 76, 471-484.
  3. Ando, M., Arima, K., Yoneda, R. and Tamura, M. (1991). Japanese summer-type hypersensitivity pneumonitis: Geographic distribution, home environment, and clinical characteristics of 621 cases. Am. Rev. Respir. Dis., 144, 765-769. https://doi.org/10.1164/ajrccm/144.4.765
  4. Cooley, J.D., Wong, W.C., Jumper, C.A. and Straus, D.C. (1998). Correlation between the prevalence of certain fungi and sick building syndrome. Occup. Environ. Med., 55, 579-584. https://doi.org/10.1136/oem.55.9.579
  5. Denning, D.W., O'Driscoll, B.R., Hogaboam, C.M., Bowyer, P. and Niven, R.M. (2006). The link between fungi and severe asthma: a summary of the evidence. Eur. Respir. J., 27, 615- 626. https://doi.org/10.1183/09031936.06.00074705
  6. Fischer, G. and Dott, W. (2003). Relevance of airborne fungi and their secondary metabolites for environmental, occupational and indoor hygiene. Arch. Microbiol., 179, 75-82. https://doi.org/10.1007/s00203-002-0495-2
  7. Fung, F. and Hughson, W.G. (2003). Health Effects of Indoor Fungal Bioaerosol Exposure. Appl. Occup. Environ. Hyg., 18, 535- 544. https://doi.org/10.1080/10473220301451
  8. Gonggam (2012). http://www2.korea.kr/newsWeb/pages/brief/part News2/view.do;JSESSIONID_ KOREA=TnwHPgGcZDh- SMGbch QPvChRf2yvvLhXZG5nvnxZLTK2Jr1VHjrwy!-108397702?call _from=extlink&call_from=extlink&dataId=155757548, accessed at 1/26/2012.
  9. Koneman, E.W., Roberts, G.D. and Wright, A.E. (1978). Practical Laboratory Mycology(2nd edition), The Williams & Wilkins Company, Baltimore MD.
  10. Lee, J.H. and Jo, W.K. (2006). Characteristics of indoor and outdoor bioaerosols at Korean high-rise apartment buildings. Environ. Res., 101, 11-17. https://doi.org/10.1016/j.envres.2005.08.009
  11. Madigan, M.T., Clark, D.P. and Martinko, J.M. (2011). Brock Biology of Microorganisms(13th Edition), Benjamin Cummings, San Francisco. CA
  12. Ministry of Environment (MOE). (2011). Korean Indoor Air Quality Control in Public Use Facilities, etc. Act. Republic of Korea.
  13. NIOSH Manual of Analytical Methods 0800. (2004). National Institute for Occupational Safety and Health, Cincinnati.
  14. Samson, R.A., Flannigan, B. and Flannigan, M.E. (1994). Recommendations. In: Health implications of fungi in indoor environments, Elsevier, New York, pp. 589-592.
  15. Straus, D.C., Cooley, J.D., Wong, W.C. and Jumper, C.A. (2003). Studies on the Role of Fungi in Sick Building Syndrome. Arch. Environ. Health, 58, 475-478. https://doi.org/10.3200/AEOH.58.8.475-478

Cited by

  1. Human exposure to polyhexamethylene guanidine phosphate from humidifiers in residential settings: Cause of serious lung disease vol.33, pp.11, 2017, https://doi.org/10.1177/0748233717724983