DOI QR코드

DOI QR Code

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

  • 투고 : 2012.01.26
  • 심사 : 2012.05.07
  • 발행 : 2012.05.31

초록

PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C ($6.43{\pm}3.24{\mu}m$) when compared to Groups A ($16.50{\pm}7.55{\mu}m$) and B ($16.27{\pm}1.71{\mu}m$) ($P$ <.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, $58.66{\pm}14.30{\mu}m$; Group B, $39.48{\pm}12.03{\mu}m$; Group C, $23.13{\pm}8.24{\mu}m$) ($P$ <.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

키워드

참고문헌

  1. Sahin S, Cehreli MC. The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 2001;10:85-92. https://doi.org/10.1097/00008505-200104000-00003
  2. Kohorst P, Brinkmann H, Li J, Borchers L, Stiesch M. Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems. Eur J Oral Sci 2009;117:319-25. https://doi.org/10.1111/j.1600-0722.2009.00622.x
  3. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.
  4. Tiossi R, Rodrigues RC, de Mattos Mda G, Ribeiro RF. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings. Int J Prosthodont 2008;21:121- 3.
  5. Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996;5:193-200. https://doi.org/10.1111/j.1532-849X.1996.tb00296.x
  6. Koke U, Wolf A, Lenz P, Gilde H. In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures. J Oral Rehabil 2004;31:477-82. https://doi.org/10.1111/j.1365-2842.2004.01271.x
  7. Silva TB, De Arruda Nobilo MA, Pessanha Henriques GE, Mesquita MF, Guimaraes MB. Influence of laser-welding and electroerosion on passive fit of implant-supported prosthesis. Stomatologija 2008;10:96-100.
  8. de Sousa SA, de Arruda Nobilo MA, Henriques GE, Mesquita MF. Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding. J Oral Rehabil 2008;35:123- 7. https://doi.org/10.1111/j.1365-2842.2003.01218.x
  9. Tiossi R, Falcao-Filho H, Aguiar Junior FA, Rodrigues RC, Mattos Mda G, Ribeiro RF. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks. J Oral Rehabil 2010;37:359-63. https://doi.org/10.1111/j.1365-2842.2010.02063.x
  10. de Aguiar FA Jr, Tiossi R, Rodrigues RC, Mattos Mde G, Ribeiro RF. An alternative section method for casting and posterior laser welding of metallic frameworks for an implantsupported prosthesis. J Prosthodont 2009;18:230-4. https://doi.org/10.1111/j.1532-849X.2008.00405.x
  11. Kikuchi H, Kurotani T, Kaketani M, Hiraguchi H, Hirose H, Yoneyama T. Effect of laser irradiation conditions on the laser welding strength of cobalt-chromium and gold alloys. J Oral Sci 2011;53:301-5. https://doi.org/10.2334/josnusd.53.301
  12. Sartori IA, Ribeiro RF, Francischone CE, de Mattos Mda G. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion. J Prosthet Dent 2004;92:132-8. https://doi.org/10.1016/j.prosdent.2004.04.001
  13. Watanabe I, Watanabe E, Atsuta M, Okabe T. Tensile strength of soldered gold alloy joints. J Prosthet Dent 1997;78:260-6. https://doi.org/10.1016/S0022-3913(97)70024-6
  14. Fonseca JC, Henriques GE, Sobrinho LC, de Goes MF. Stressrelieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings. Dent Mater 2003;19:686-91. https://doi.org/10.1016/S0109-5641(03)00014-9
  15. Wettstein F, Sailer I, Roos M, Hammerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008;116:272-9. https://doi.org/10.1111/j.1600-0722.2008.00527.x
  16. Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-5.
  17. Shimakura M, Yamada S, Takeuchi M, Miura K, Ikeyama J. Influence of irradiation conditions on the deformation of pure titanium frames in laser welding. Dent Mater J 2009;28:243-7. https://doi.org/10.4012/dmj.28.243
  18. Nunez-Pantoja JM, Vaz LG, No′bilo MA, Henriques GE, Mesquita MF. Effects of laser-weld joint opening size on fatigue strength of Ti-6Al-4V structures with several diameters. J Oral Rehabil 2011;38:196-201. https://doi.org/10.1111/j.1365-2842.2010.02140.x
  19. Zupancic R, Legat A, Funduk N. Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints. J Prosthet Dent 2006;96:273-82. https://doi.org/10.1016/j.prosdent.2006.08.006
  20. Gemalmaz D, Berksun S, Alkumru HN, Kasapoglu C. Thermal cycling distortion of porcelain fused to metal fixed partial dentures. J Prosthet Dent 1998;80:654-60. https://doi.org/10.1016/S0022-3913(98)70051-4
  21. Bridger DV, Nicholls JI. Distortion of ceramometal fixed partial dentures during the firing cycle. J Prosthet Dent 1981;45:507- 14. https://doi.org/10.1016/0022-3913(81)90036-6
  22. Campbell SD, Pelletier LB. Thermal cycling distortion of metal ceramics: Part I-Metal collar width. J Prosthet Dent 1992;67:603-8. https://doi.org/10.1016/0022-3913(92)90155-4
  23. Campbell SD, Sirakian A, Pelletier LB, Giordano RA. Effects of firing cycle and surface finishing on distortion of metal ceramic castings. J Prosthet Dent 1995;74:476-81. https://doi.org/10.1016/S0022-3913(05)80348-8
  24. Twiggs SW, Searle JR, Ringle RD, Fairhurst CW. A rapid heating and cooling rate dilatometer for measuring thermal expansion in dental porcelain. J Dent Res 1989;68:1316-8. https://doi.org/10.1177/00220345890680090501
  25. Bryant RA, Nicholls JI. Measurement of distortions in fixed partial dentures resulting from degassing. J Prosthet Dent 1979;42:515-20. https://doi.org/10.1016/0022-3913(79)90244-0
  26. Ziebert GJ, Hurtado A, Glapa C, Schiffleger BE. Accuracy of one-piece castings, preceramic and postceramic soldering. J Prosthet Dent 1986;55:312-7. https://doi.org/10.1016/0022-3913(86)90110-1
  27. Zervas PJ, Papazoglou E, Beck FM, Carr AB. Distortion of threeunit implant frameworks during casting, soldering, and simulated porcelain firings. J Prosthodont 1999;8:171-9. https://doi.org/10.1111/j.1532-849X.1999.tb00032.x

피인용 문헌

  1. Influence of Resin Cements on the Tension Force of Cast Frameworks Made by the Technique of Framework Cemented on Prepared Abutments vol.26, pp.4, 2015, https://doi.org/10.1590/0103-6440201302423
  2. Evaluation of Marginal Misfit of Metal Frameworks Welded by Gas-Torch, Laser, and Tungsten Inert Gas Methods vol.2018, pp.1687-8736, 2018, https://doi.org/10.1155/2018/9828929
  3. Dimensional accuracy of different impression techniques of partially edentulous mandibular arch vol.65, pp.1, 2012, https://doi.org/10.1590/1981-863720170001000043219
  4. Systematic review and meta-analysis of welding procedures in one-piece cast implant-supported frameworks vol.33, pp.None, 2012, https://doi.org/10.1590/1807-3107bor-2019.vol33.0110
  5. Comparing different bar materials for mandibular implant-supported overdenture: Finite-element analysis vol.30, pp.5, 2012, https://doi.org/10.4103/ijdr.ijdr_97_18
  6. Implant framework misfit: A systematic review on assessment methods and clinical complications vol.23, pp.2, 2012, https://doi.org/10.1111/cid.12968