Abstract

In these days, the design of a structure for reducing or eliminating noise and vibration is getting more important, as the social demands for reducing environmental pollution rise. In this paper, the basic concept and performance verification test results of the recently developed vertical vibration isolator are presented. The isolator attenuates vibration using the damping action from the friction plane made of PTFE and provides the restoring force from the polyurethane springs arranged in vertical and horizontal directions. The performance verification tests consist of a test for identifying performance change during load rate variation and a test for confirming the force-displacement relationship assumption in vibration force range.

최근 환경 공해 저감에 대한 사회적 요구가 높아짐에 따라 구조물의 방음, 방진 설계가 더욱 중요해지고 있다. 이 논문에서는 최근 개발된 수직형 면진장치의 기본 개념 및 성능 확인 실험 결과를 제시하였다. 개발된 면진장치는 PTFE 재질 마찰면의 마찰작용을 이용하여 수직방향의 진동을 감쇠시키고 수평 및 수직으로 배치된 폴리우레탄 소재의 스프링을 통하여 복원력을 제공하는 구조이다. 성능확인 실험은 하중 재하 속도에 변화에 따른 성능 변화추이를 파악하기 위한 실험과 고정하중이 적용된 후 발생되는 진동하중 작용 시 가정된 하중-변위 특성을 확인하기 위한 실험으로 구성하였다.

Keywords

References

  1. Baek, J.H., Lee, Y.I., Lee, J.T. (2011). "Seismic isolation design for nuclear power station." Journal of Korean Society of Hazard Mitigation, Vol.11, No.2, pp.50-59.
  2. Biswas, S.K., Vijayan, K. (1992). "Friction and wear of PTFE - a review." Wear, Vol.158, pp.193-211. https://doi.org/10.1016/0043-1648(92)90039-B
  3. Hwang, J. (2004). " Vibration Control System for Serviceability Enhancement of a Structure." Review of Architecture and Building Science, Vol.48, No.7, pp.56-61.
  4. Jang, S.Y., Cho, H.-H., Yang, S.C. (2010). "Vibration analysis of station under railway lines with floating slab track." Proceedings of 2010 Spring Conference, Korean Society for Railway, pp.1719-1724.
  5. Jeon, G.-S., Hong, C.-S. (2010). "Development of supersize rubber using castable urethane elastomer." Proceedings of Annual Spring Conference, Earthquake Engineering Society of Korea, pp.249-252.
  6. Kim, J.H., Youn, S.H. (2008). "The review of floating slab tracks for vibration reduction of railway station." Korean Journal of Environmental Engineers, Vol.30, No.6, pp.581-586.
  7. Lee, D.-G., Kim, T.-H. (2006). "Application of seismic isolation and vibration control in Korea." Journal of the Earthquake Engineering Society of Korea, Vol.10 No.6, pp.67-77. https://doi.org/10.5000/EESK.2006.10.6.067
  8. Park, H.G., Lee, Y.I., Jung, D.Y. (2011). "Experimental and analytical study of the dynamic behavior of a polyyrethane spring restoring disk bearing." Journal of the Earthquake Engineering Society of Korea, Vol.15, No.2, pp.61-69. https://doi.org/10.5000/EESK.2011.15.2.061
  9. Tecklenburg, M. (2003). "Vibration control in tramway and L.R.T. systems." International Conference on Contemporary Tram and L.R.T. Systems, Greece.
  10. Yu, S.M., Jung, D.Y. (2011). "Development of the vertical isolation device." Proceedings of Annual Spring Conference, Earthquake Engineering Society of Korea, pp.221-224.