References
- S. Coenen, S. Tenbohlen, S. M. Markalous, T. Strehl, "Performance Check and Sensitivity Verification for UHF PD Measurements on Power Transformers", Proc. 15th Int. Symp. on High Voltage Engineering, Paper No. T7-100, jubljana, Slovenia, 2007.
- S. Coenen, S. Tenbohlen, S. M. Markalous, T. Strehl, "Sensitivity of UHF PD measurements in power transformers", IEEE Trans. Dielectr. Electr. Insul., vol. 15, no. 6, pp. 1553-1558, 2008. https://doi.org/10.1109/TDEI.2008.4712657
- Seoung-Yong Jun, Cheol-Hwi Ryu, Yun-Sok Lim, Ja- Ho Lee, Ja-Yoon Koo, "Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)", Journal of Electrical Engineering & Technology. vol. 2, no. 1, pp. 118-122, 2007. https://doi.org/10.5370/JEET.2007.2.1.118
- K.-J. Lim, S.-H. Yang, D.-H. Shin, N.-J. Park, D.-H. Park, "A Study on the design of a planar loop sensor for partial discharge diagnosis of 22.9 kV XLPE Power Cables", Journal of Electrical Engineering & Technology, vol.3, no.4, pp.559-565, Dec. 2008. https://doi.org/10.5370/JEET.2008.3.4.559
- F. H. Kreuger, Partial Discharge Detection in High-Voltage Equipment, Butterworths, 1989.
- National Emergency Management Agency, The analysis of fire occurrence present condition, 2010.
- H. Okubo, H. Yamashita, N. Hayakawa, T. Ueda, and M. Hikita, "Electromagnetic Spectrum Radiated from Gas Discharges and its Relation to Partial-Discharge Characteristics", European Transactions on Electrical Power, vol. 7, no. 1, pp. 57-63, 1997.
- L. A. Dissado, S. J. Dodd, J. V. Champion, P. I. Williams and J. M. Alison, "Propagation of Electrical Tree Structures in Solid Polymeric Insulation", IEEE Trans. Dielectr. Electr. Insul., vol. 4, no. 3, pp. 259-279, 1997. https://doi.org/10.1109/94.598282
- J. R. Dunki-Jacobs, "The effects of arcing ground faults on low-voltage system design", IEEE Trans. Industry Applications, vol. IA-8, no. 3, pp. 223-230, 1972. https://doi.org/10.1109/TIA.1972.349750
- T. S. Sidhu, G. Singh, and M. S. Sachdev, "Microprocessor based Instrument for Detecteting and locating Electric Arcs", IEEE Trans. Power Delivery, vol. 13, no. 4, pp. 1079-1085, 1998. https://doi.org/10.1109/61.714459
- M. D. Judd, O. Farish, B.F. Hampton, "Excitation of UHF signals by partial discharges in GIS", IEEE Trans. Dielectr. Electr. Insul., vol. 3, no. 2, pp. 213-228, 1996. https://doi.org/10.1109/94.486773
- Shea J. J., "Conditions for series arcing phenomena in PVC wiring", Proceedings of the Fifty-First IEEE Holm Conference on Electrical Contacts, pp.167-175, Vancouver, Canada, Sept. 2005.
- J. C. Fothergill, L. A. Dissado and P. J. J. Sweeney, "A Discharge Avalanche Theory for the Propagation of Electrical Tree", IEEE Trans. Dielectr. Electr. Insul., vol. 1, no. 3, pp. 474-486, 1994. https://doi.org/10.1109/94.300291
- C. -S. Maroni, R. Cittadini, Y. Cadoux, and M. Serpinet, "Series arc detection in low voltage distribution switchboard using spectral analysis", Proc. of the Sixth International Symposium on Signal Processing and its Applications, vol. 2, Kuala Lumpur, Malaysia, 2001
- P. Agoris, P. Cichecki, S. Meijer, E. Gulski and J. J. Smit, "Analysis of Artificial Defects in Transformer Insulation using the UHF technique", Proc. of the 15th Int. Symp. on High Voltage Engineering, Paper No. T7-737, Ljubljana, Slovenia, 2007.
- G.-S. Kil, I.-K. Kim, D.-W. Park, S.-Y. Choi, C.-Y. Park, "Measurements and analysis of the acoustic signals produced by partial discharges in insulation oil", Cur. Appl. Phys., vol. 9, no. 2, pp. 296-300, 2009. https://doi.org/10.1016/j.cap.2008.01.018
- UL 1699, "UL Standard for Arc-Fault Circuit- Interrupters", Second Edition, 2006.
Cited by
- Optimal Design of an Antenna for the Detection of Partial Discharges in Insulation Oil vol.26, pp.4, 2013, https://doi.org/10.4313/JKEM.2013.26.4.309
- Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil vol.8, pp.6, 2013, https://doi.org/10.5370/JEET.2013.8.6.1468