DOI QR코드

DOI QR Code

벤치스케일(0.36 m × 22 m) 다단형 기포탑에서 다공판이 기포의 거동 및 기체 체류량에 미치는 영향

The Effect of Partitioning Porous Plate on Bubble Behavior and Gas Hold-up in a Bench Scale (0.36 m × 22 m) Trayed Bubble Column

  • 양정훈 (한국에너지기술연구원 청정석탄센터) ;
  • 허영걸 (한국에너지기술연구원 청정석탄센터) ;
  • 이호태 (한국에너지기술연구원 청정석탄센터) ;
  • 양정일 (한국에너지기술연구원 청정석탄센터) ;
  • 김학주 (한국에너지기술연구원 청정석탄센터) ;
  • 천동현 (한국에너지기술연구원 청정석탄센터) ;
  • 박지찬 (한국에너지기술연구원 청정석탄센터) ;
  • 정헌 (한국에너지기술연구원 청정석탄센터)
  • Yang, Jung Hoon (Clean Coal Center, Korea Institute of Energy Research) ;
  • Hur, Young Gul (Clean Coal Center, Korea Institute of Energy Research) ;
  • Lee, Ho-Tae (Clean Coal Center, Korea Institute of Energy Research) ;
  • Yang, Jung-Il (Clean Coal Center, Korea Institute of Energy Research) ;
  • Kim, Hak-Joo (Clean Coal Center, Korea Institute of Energy Research) ;
  • Chun, Dong Hyun (Clean Coal Center, Korea Institute of Energy Research) ;
  • Park, Ji Chan (Clean Coal Center, Korea Institute of Energy Research) ;
  • Jung, Heon (Clean Coal Center, Korea Institute of Energy Research)
  • 투고 : 2011.09.30
  • 심사 : 2011.12.05
  • 발행 : 2012.06.01

초록

기포탑 반응기에서의 기체 체류량은 기포의 크기 분포 및 상승 속도와 밀접한 연관성을 갖는다. 따라서 많은 연구자들에 의하여 기포탑 반응기 내에 기포의 크기를 제어하기 위한 연구들이 진행되어 왔다. 본 연구에서는 스파져 이외의 영역에서도 기포의 거동을 제어하고 기체 체류량을 증진시키기 위하여 다단형 기포탑 반응기를 사용하였다. 특히, 3 종류의 서로 다른 크기의 반응기를 사용하여 다단 다공판이 기포의 유동 특성에 미치는 효과를 확인하였다. 나아가 개별 기포가 다공판을 통과하였을 때의 쪼개짐 빈도수 및 크기 분포 변화에 대하여 관찰함으로써 다공판의 영향에 대한 이해를 넓혔다. 또한 다양한 다공판 배치 형태에 따른 유동 특성을 관찰함으로써 다단형 기포탑 반응기에서의 다공판 설치에 대한 기준을 제시할 수 있었으며, 이를 바탕으로 높이 22 m, 직경 0.36 m의 벤치 스케일 다단형 기포탑 반응기를 제작하여 그 성능을 확인하였다.

The gas hold-up has a strong relationship with the size distribution and rising velocities of bubbles in a bubble column. Therefore, many previous researchers have studied on the hydrodynamics focusing on the bubble size variation in bubble column. In this study, the bubble behavior was influenced by partitioning porous plates installed at a certain height in a trayed bubble column. The gas hold-up was increased in non-sparging region (H/D > 5) as well as sparging region. We identified the effect of the partitioning porous plate using three trayed bubble columns with different reactor geometries. Furthermore, the bubble break-up frequency and size distribution were observed before and after individual bubbles penetrated through the plate. The arrangement of the plates was also investigated using a 0.15-m-in-diameter bubble column. Based on the result, we applied this design concept to a 0.36-m-in-diameter, 22 m tall trayed bubble column and identified the effect of the partitioning porous plate on the gas hold-up increase.

키워드

참고문헌

  1. Letzel, H. M., Schouten, J. C., Krishna, R. and van den Bleek, C. M., "Gas Holdup and Mass Transfer in Bubble Column Reactors Operated at Elevated Pressure," Chem. Eng. Sci., 54, 2237-2246(1999). https://doi.org/10.1016/S0009-2509(98)00418-7
  2. Yang, J. H., Yang, J. I., Kim, H. J., Chun, D. H., Lee, H. T. and Jung, H., "Two Regime Transitions to Pseudo-homogeneous and Heterogeneous Bubble Flow for Various Liquid Viscosities," Chem. Eng. Process., 49, 1044-1050(2010). https://doi.org/10.1016/j.cep.2010.07.015
  3. Clift, R., Grace, J. R. and Weber, M. E., "Bubbles, Drops and Particles," Dover publications, New York(1978).
  4. Polli, M., Stanislao, M. D., Bagatin, R., Bakr, E. A. and Masi, M., "Bubble Size Distribution in the Sparger Region of Bubble Columns," Chem. Eng. Sci., 57, 197-205(2002). https://doi.org/10.1016/S0009-2509(01)00301-3
  5. Tsuchiya, K. and Nakanishi, O., "Gas Holdup Behavior in a Tall Bubble Column with Perforated Plate Distributors," Chem. Eng. Sci., 47, 3347-3354(1992). https://doi.org/10.1016/0009-2509(92)85044-C
  6. Thorat, B. N., Shevade, A. V., Bhilegaonkar, K. N., Aglawe, R. H., Veera, U. P., Thakre, S. S., Pandit, A. B., Sawant, S. B. and Joshi, J. B., "Effect of Sparger Design and Height to Diameter Ratio on Fractional Gas Hold-up in Bubble Columns," Chem. Eng. Res. Des., 76, 823-834(1998). https://doi.org/10.1205/026387698525577
  7. Thaker, K. and Rao, D. P., "Effects of Gas Redispersion and Liquid Height on Gas-liquid Hydrodynamics in a Multistage Bubble Column," Chem. Eng. Res. Des., 85, 1362-1374(2007). https://doi.org/10.1016/S0263-8762(07)73176-3
  8. Alvare, J. and Al-Dahhan, M. H., "Liquid Phase Mixing in Trayed Bubble Column Reactors," Chem. Eng. Sci., 61, 1819-1835(2006). https://doi.org/10.1016/j.ces.2005.10.015
  9. Alvare, J. and Al-Dahhan, M. H., "Gas Holdup in Trayed Bubble Column Reactors," Ind. Eng. Chem. Res., 45, 3320-3326(2006). https://doi.org/10.1021/ie051442s
  10. Doshi, Y. K. and Pandit, A. B., "Effect of Internals and Sparger Design on Mixing Behavior in Sectionalized Bubble Column," Chem. Eng. J., 112, 117-129(2005). https://doi.org/10.1016/j.cej.2005.07.004
  11. Dreher, A. J. and Krishna, R., "Liquid-phase Backmixing in Bubble Columns, Structured by Introduction of Partition Plates," Cataly. Today, 69, 165-170(2001). https://doi.org/10.1016/S0920-5861(01)00365-0