DOI QR코드

DOI QR Code

A Comparative Analysis between Rigorous and Approximate Approaches for LiDAR System Calibration

  • Kersting, Ana Paula (Department of Geomatics Engineering, University of Calgary) ;
  • Habib, Ayman (Department of Geomatics Engineering, University of Calgary)
  • 투고 : 2012.09.11
  • 심사 : 2012.11.06
  • 발행 : 2012.12.31

초록

LiDAR systems provide dense and accurate topographic information. A pre-requisite to achieving the potential accuracy of LiDAR is having a proper system calibration, which aims at estimating all the systematic errors in the system measurements and the mounting parameters relating the different components. This paper presents a rigorous and two approximate methods for LiDAR system calibration. The rigorous approach makes use of the LiDAR equation and the system raw measurements. The approximate approaches utilize simplified LiDAR equations using some assumptions, which allow for less strict requirements regarding the raw measurements. The first presented approximate method, denoted as quasi-rigorous, assumes that we are dealing with a vertical platform (i.e., small pitch and roll angles). This method requires time-tagged point cloud and trajectory position data. The second approximate method, denoted as simplified, assumes that we are dealing with parallel strips, vertical platform, and minor terrain elevation variations compared to the flying height above ground. Such method can be performed using the LiDAR point cloud only. Experimental results using a real dataset, whose characteristics deviate to some extent from the utilized assumptions in the approximate methods, are presented to provide a comparative analysis of the outcome from the introduced methods.

키워드

참고문헌

  1. Bang, K., Habib, A., and Kersting, A., (2010), Estimation of Biases in LiDAR System Calibration Parameters using Overlapping Strips. Canadian Journal of Remote Sensing, Vol. 36, Suppl. 2, pp. S335-S354. https://doi.org/10.5589/m10-054
  2. Burman, H., (2000), Calibration and Orientation of Airborne Image and Laser Scanner Data Using GPS and INS, Ph.D. dissertation, Royal Institute of Technology, Stockholm, 125p.
  3. Filin, S., (2001), Calibration of Spaceborne and Airborne Laser Altimeters Using Natural Surfaces, Ph.D. dissertation, Department of Civil and Environmental Engineering and Geodetic Science, the Ohio-State University, Columbus, OH, 129p.
  4. Friess, P., (2006), Toward a rigorous methodology for airborne laser mapping, Proceedings of EuroCOW, Castelldefels, Spain, unpaginated CD-ROM.
  5. Habib, A., K. Bang, A.P. Kersting, and D.C. Lee, (2009), Error budget of LiDAR Systems and Quality Control of the Derived Data, Photogrammetric Engineering and Remote Sensing, Vol. 75, No. 9, pp. 1093-1108. https://doi.org/10.14358/PERS.75.9.1093
  6. Habib, A., A.P. Kersting, K. Bang, and D.C. Lee, (2010a), Alternative methodologies for the internal quality control of parallel LiDAR strips, IEEE Transactions on Geoscience and Remote Sensing, Vol. 48, No. 1, pp. 221-236. https://doi.org/10.1109/TGRS.2009.2026424
  7. Habib A., K. Bang, A. P. Kersting, and J. Chow, (2010b), Alternat ive Methodologies for LiDAR System Calibration, Remote Sensing, Vol. 2, No. 3, pp. 874-907. https://doi.org/10.3390/rs2030874
  8. Habib, A., Kersting, A., Shaker, A., and Yan, W., (2011), Geometric Calibration and Radiometric Correction of LiDAR Data and their Impact on the Quality of Derived Products. Sensors, Vol. 11, No. 9, pp. 9069 - 9097. https://doi.org/10.3390/s110909069
  9. Morin, K.W., (2002), Calibration of Airborne Laser Scanners, M.S. thesis, University of Calgary, Department of Geomatics Engineering, Calgary, AB, 125p.
  10. Kersting, A.P., (2011), Quality Assurance of Multi-Sensor Systems, Ph.D. dissertation, University of Calgary, Department of Geomatics Engineering, Calgary, AB, 265p.
  11. Kersting, A.P., Habib, A., Bang, K., and Skaloud, J., (2012), Automated approach for rigorous light detection and ranging system calibration without preprocessing and strict terrain coverage requirements. Journal of Optical Engineering, 51, 076201 (2012), DOI:10.1117/1.OE.51.7.07620.
  12. Schenk, T., (2001), Modeling and Analyzing Systematic Errors in Airborne Laser Scanners, Technical Report in Photogrammetry No. 19, The Ohio State University.
  13. Skaloud, J., J. Vallet, K. Keller, G. Veyssiere, and O. Koelbl, (2005), HELIMAP: Rapid large scale mapping using handheld LiDAR/CCD/GPS/INS sensors on helicopters, Proceedings ION GNSS 2005, Long Beach, CA, USA, 13-16 September, pp. 2461-2467 CDROM.
  14. Skaloud, J., and D. Lichti, (2006), Rigorous Approach to Bore-Sight Self-Calibration in Airborne Laser Scanning, ISPRS Journal of Photogrammetry and Remote Sensing, 61: 47-59. https://doi.org/10.1016/j.isprsjprs.2006.07.003
  15. Toth, C.K., (2002), Calibrating airborne lidar systems, Proceedings of ISPRS Commission II Symposium, Xi'an, China, pp. 475-480.
  16. Wehr, A., and U. Lohr, (1999), Airborne laser scanning- an introduction and overview, ISPRS Journal of Photogrammetry and Remote Sensing, Vol. 54, pp. 68-82. https://doi.org/10.1016/S0924-2716(99)00011-8

피인용 문헌

  1. Strip Adjustment of Airborne Laser Scanner Data Using Area-based Surface Matching vol.32, pp.6, 2014, https://doi.org/10.7848/ksgpc.2014.32.6.625