V 형상을 가지는 원자현미경 Cantilever의 정량적 마찰력 교정

Quantitative Lateral Force Calibration of V-shaped AFM Cantilever

  • Lee, Huijun (School of Mechanical Engineering, University of Ulsan) ;
  • Kim, Kwanghee (School of Mechanical Engineering, University of Ulsan) ;
  • Kim, Hyuntae (School of Mechanical Engineering, University of Ulsan) ;
  • Kang, Boram (School of Mechanical Engineering, University of Ulsan) ;
  • Chung, Koo-Hyun (School of Mechanical Engineering, University of Ulsan)
  • 투고 : 2012.06.21
  • 심사 : 2012.08.16
  • 발행 : 2012.10.31

초록

Atomic force microscopy (AFM) has been used as a tool, not only for imaging surfaces, but also for measuring surface forces and mechanical properties at the nano-scale. Force calibration is crucial for quantitatively measuring the forces that act between the AFM probe of a force sensing cantilever and a sample. In this work, the lateral force calibrations of a V-shaped cantilever were performed using the finite element method, multiple pivot loading, and thermal noise methods. As a result, it was shown that the multiple pivot loading method was appropriate for the lateral force calibration of a V-shaped cantilever. Further, through crosschecking of the abovementioned methods, it was concluded that the thermal noise method could be used for determining the lateral spring constants as long as the lateral deflection sensitivity was accurately determined. To obtain the lateral deflection sensitivity from the sticking portion of the friction loop, the contact stiffness should be taken into account.

키워드

참고문헌

  1. Binnig, G., Quate, C. F., and Gerber, C., "Atomic Force Microscope," Phys Rev Lett, Vol. 56, pp. 930-933, 1986. https://doi.org/10.1103/PhysRevLett.56.930
  2. Chung, K. H., Bhadriraju, K., Spurlin, T. A., Cook, R. F., and Plant, A. L., "Nanomechanical Properties of Thin Films of Type I Collagen Fibrils," Langmuir, Vol. 26, pp. 3629-3636, 2010. https://doi.org/10.1021/la903073v
  3. Giesbers, A. J. M., Zeitler, U., Neubeck, S., Freitag, F., Novoselov, K. S., and Maan, J. C., "Nanolithography and Manipulation of Graphene using an Atomic Force Microscope," Solid State Commun, Vol. 147, pp. 366-369, 2008. https://doi.org/10.1016/j.ssc.2008.06.027
  4. Bordag, M., Ribayrol, A., Conache, G., Fröberg, L., Gray, S., Samuelson, L., Montelius, L., and Pettersson, H., "Shear Stress Measurements on InAs Nanowires by AFM Manipulation," Small, Vol. 3, pp. 1398-1401, 2007. https://doi.org/10.1002/smll.200700052
  5. Bharat Bhushan and Kwang Joo Kwak and,Manuel Palacio, "Nanotribology and Nanomechanics of AFM Probe-Based Data Recording Technology," J Phys: Condens Matter, Vol. 20, pp. 365207, 2008. https://doi.org/10.1088/0953-8984/20/36/365207
  6. Hutter, J. L. and Bechhoefer, J., "Calibration of Atomic-Force Microscope Tips," Rev. Sci. Instrum., Vol. 64, pp. 1868-1873, 1993. https://doi.org/10.1063/1.1143970
  7. Cleveland, J. P., Manne, S., Bocek, D., and Hansma, P. K., "A Nondestructive Method for Determining the Spring Constant of Cantilevers for Scanning Force Microscopy," Rev. Sci. Instrum., Vol. 64, pp. 403-405, 1993. https://doi.org/10.1063/1.1144209
  8. Sader, J. E., Chon, J. W. M., and Mulvaney, P., "Calibration of Rectangular Atomic Force Microscope Cantilevers," Rev. Sci. Instrum., Vol. 70, pp. 3967- 3969, 1999. https://doi.org/10.1063/1.1150021
  9. Torii, A., Sasaki, M., Hane, K., and Okuma, S., "A Method for Determining the Spring Constant of Cantilevers for Atomic Force Microscopy," Meas Sci Technol, Vol. 7, pp. 179-184, 1996. https://doi.org/10.1088/0957-0233/7/2/010
  10. Chung, K. H., Shaw, G. A., and Pratt, J. R., "Accurate Noncontact Calibration of Colloidal Probe Sensitivities in Atomic Force Microscopy," Rev. Sci. Instrum., Vol. 80, pp. 065107, 2009. https://doi.org/10.1063/1.3152335
  11. Ogletree, D. F., Carpick, R. W., and Salmeron, M., "Calibration of Frictional Forces in Atomic Force Microscopy," Rev. Sci. Instrum., Vol. 67, pp. 3298- 3306, 1996. https://doi.org/10.1063/1.1147411
  12. Varenberg, M., Etsion, I., and Halperin, G., "An Improved Wedge Calibration Method for Lateral Force in Atomic Force Microscopy," Rev. Sci. Instrum., Vol. 74, pp. 3362-3367, 2003. https://doi.org/10.1063/1.1584082
  13. Wang, F. and Zhao, X., "Effect of Contact Stiffness on Wedge Calibration of Lateral Force in Atomic Force Microscopy," Rev. Sci. Instrum., Vol. 78, pp. 043701, 2007. https://doi.org/10.1063/1.2720723
  14. Li, Q., Kim, K. -., and Rydberg, A., "Lateral Force Calibration of an Atomic Force Microscope with a Diamagnetic Levitation Spring System," Rev. Sci. Instrum., Vol. 77, pp. 065105, 2006. https://doi.org/10.1063/1.2209953
  15. Bogdanovic, G., Meurk, A., and Rutland, M. W., "Tip Friction - Torsional Spring Constant Determination," Colloid Surf B-Biointerfaces, Vol. 19, pp. 397-405, 2000. https://doi.org/10.1016/S0927-7765(00)00147-8
  16. Chung, K. H. and Reitsma, M. G., "Note: Lateral Force Microscope Calibration using Multiple Location Pivot Loading of Rectangular Cantilevers," Rev. Sci. Instrum., Vol. 81, pp. 026104, 2010. https://doi.org/10.1063/1.3276709
  17. Neumeister, J. M. and Ducker, W. A., "Lateral, Normal, and Longitudinal Spring Constants of Atomic Force Microscopy Cantilevers," Rev. Sci. Instrum., Vol. 65, pp. 2527-2531, 1994. https://doi.org/10.1063/1.1144646
  18. Higgins, M. J., Proksch, R., Sader, J. E., Polcik, M., Endoo, S. M., Cleveland, J. P., and Jarvis, S. P., "Noninvasive Determination of Optical Lever Sensitivity in Atomic Force Microscopy," Rev. Sci. Instrum., Vol. 77, pp. 013701, 2006. https://doi.org/10.1063/1.2162455
  19. Wagner, K., Cheng, P., and Vezenov, D., "Noncontact Method for Calibration of Lateral Forces in Scanning Force Microscopy," Langmuir, Vol. 27, pp. 4635-4644, 2011. https://doi.org/10.1021/la1046172
  20. Cain, R. G., Biggs, S., and Page, N. W., "Force Calibration in Lateral Force Microscopy," J. Colloid Interface Sci., Vol. 227, pp. 55-65, 2000. https://doi.org/10.1006/jcis.2000.6840