DOI QR코드

DOI QR Code

Performance Variation with Length of Internal Heat Exchanger in CO2 Cooling Cycle Using an Ejector

이젝터를 적용한 이산화탄소 냉동사이클의 내부열교환기 길이에 따른 성능 변화

  • Kang, Byun (Graduate School of Mechanical Engineering, Chosun University) ;
  • Cho, Hong-Hyun (Department of Mechanical Engineering, Chosun University)
  • 강변 (조선대학교 대학원) ;
  • 조홍현 (조선대학교 기계공학과)
  • Received : 2011.10.06
  • Published : 2012.02.10

Abstract

Recently, many researchers have studied the performance of the transcritical $CO_2$ refrigeration cycle in order to improve the system efficiency. In this study, the length of IHX in the $CO_2$ ejector cycle was varied so as to evaluate the performance improvement. As a result, compressor work and cooling capacity was increased by 3% and 5% as the length of internal heat exchanger was changed from 3 m to 15 m. The best COP was appeared at internal heat exchanger length of 12 m, and it was 3.01. Besides, the length of internal heat exchanger has a big effect to pressure lift ratio and entrainment ratio in the ejector $CO_2$ cycle and it may be changed with operating conditions and system specifications.

Keywords

References

  1. Nakagawa, M., Marasigan, A. R., Matsukawa, T., and Kurashina, A., 2011, Experimental analysis on the effect of internal heat exchanger in transcritical $CO_{2}$ refrigeration cycle with two-phase ejector, International Journal of Refrigeration, Vol. 34, pp. 1577-1586. https://doi.org/10.1016/j.ijrefrig.2010.03.007
  2. Li, D. and Groll, A., 2005, Transcritical $CO_{2}$ refrigeration cycle with ejector-expansion device, International Journal of Refrigeration, Vol. 28, pp. 766-773. https://doi.org/10.1016/j.ijrefrig.2004.10.008
  3. Sarkar, J., 2008, Optimization of ejector-expansion transcritical $CO_{2}$ heat pump cycle, Energy, Vol. 33, pp. 1399-1406. https://doi.org/10.1016/j.energy.2008.04.007
  4. Ortiz, T. M., Li, D., and Groll, A. E., 2003, Evaluation of the Performance Potential of $CO_{2}$ as a Refrigerant in Air-to-Air Conditioner and Heat Pumps:System Modelling and Analysis, ARTI final report No. 21CR/610- 10030.
  5. Gnielinski, V., 1976, New equations for heat and mass transfer in turbulent pipe and channel flow, International Chemical Engineering, Vol. 16, pp. 59-68.
  6. Churchill, S. W., 1977, Friction-factor equation span all fluid flow regimes, Chemical Engineering, Vol. 7, pp. 91-92.
  7. Yoon, S. H., 2002, Studies on the Characteristics of Evaporation and supercritical Gas Cooling Heat Transfer of Carbon Dioxide, Ph. D. thesis, Seoul University, Seoul, Korea.
  8. Wang, C. C., Lee., S. W., and Sheu, W. J., 2001, A Comparative Study of Compact Enhanced Fin-and-Tube Heat Exchanges, International Journal of Heat and Mass Transfer, Vol. 44, pp. 3565-3573. https://doi.org/10.1016/S0017-9310(01)00011-4
  9. ASHRAE, 1983, Methods of testing for seasonal efficiency of unitaty air-conditioner and heat pumps, ASHRAE Standard, p. 116.
  10. Kang, B. and Cho, H. H., 2011, Comparison of Performance in $CO_{2}$ Cooling System with an Ejector for Various Operating Condtitions, SA REK, Vol. 23, pp. 505-512.

Cited by

  1. Study on the Performance Improvement for an Automobile Air Conditioning System Using Alternative Refrigerant R1234yf vol.25, pp.4, 2013, https://doi.org/10.6110/KJACR.2013.25.4.201