References
- Fox NC, Cousens S, Scahill R, Harvey RJ, Rossor MN. Using serial registered brain magnetic resonance imaging to measure disease progression in Alzheimer disease: power calculations and estimates of sample size to detect treatment effects. Arch Neurol 2000;57:339-344 https://doi.org/10.1001/archneur.57.3.339
- Jack CR Jr, Shiung MM, Weigand SD, O'Brien PC, Gunter JL, Boeve BF, et al. Brain atrophy rates predict subsequent clinical conversion in normal elderly and amnestic MCI. Neurology 2005;65:1227-1231 https://doi.org/10.1212/01.wnl.0000180958.22678.91
- Maldjian JA, Laurienti PJ, Kraft RA, Burdette JH. An automated method for neuroanatomic and cytoarchitectonic atlas-based interrogation of fMRI data sets. Neuroimage 2003;19:1233-1239 https://doi.org/10.1016/S1053-8119(03)00169-1
- Gonoi W, Abe O, Yamasue H, Yamada H, Masutani Y, Takao H, et al. Age-related changes in regional brain volume evaluated by atlas-based method. Neuroradiology 2010;52:865-873 https://doi.org/10.1007/s00234-009-0641-5
- Rojas R, Rodríguez AO. Numerical study of the SNR and SAR of MRI coil arrays. Conf Proc IEEE Eng Med Biol Soc 2007;2007:1196-1199
- Simmons A, Tofts PS, Barker GJ, Arridge SR. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn Reson Med 1994;32:121-128 https://doi.org/10.1002/mrm.1910320117
- Sled JG, Zijdenbos AP, Evans AC. A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imaging 1998;17:87-97 https://doi.org/10.1109/42.668698
- Arnold JB, Liow JS, Schaper KA, Stern JJ, Sled JG, Shattuck DW, et al. Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects. Neuroimage 2001;13:931-943
- Leow AD, Klunder AD, Jack CR Jr, Toga AW, Dale AM, Bernstein MA, et al. Longitudinal stability of MRI for mapping brain change using tensor-based morphometry. Neuroimage 2006;31:627-640 https://doi.org/10.1016/j.neuroimage.2005.12.013
- Vovk U, Pernus F, Likar B. A review of methods for correction of intensity inhomogeneity in MRI. IEEE Trans Med Imaging 2007;26:405-421
- Ashburner J, Friston KJ. Unified segmentation. Neuroimage 2005;26:839-851 https://doi.org/10.1016/j.neuroimage.2005.02.018
- Fazekas F, Chawluk JB, Alavi A, Hurtig HI, Zimmerman RA. MR signal abnormalities at 1.5 T in Alzheimer's dementia and normal aging. AJR Am J Roentgenol 1987;149:351-356 https://doi.org/10.2214/ajr.149.2.351
- Jack CR Jr, Bernstein MA, Fox NC, Thompson P, Alexander G, Harvey D, et al. The Alzheimer's Disease Neuroimaging Initiative (ADNI): MRI methods. J Magn Reson Imaging 2008;27:685-691 https://doi.org/10.1002/jmri.21049
- Schnack HG, van Haren NE, Hulshoff Pol HE, Picchioni M, Weisbrod M, Sauer H, et al. Reliability of brain volumes from multicenter MRI acquisition: a calibration study. Hum Brain Mapp 2004;22:312-320 https://doi.org/10.1002/hbm.20040
- van Haren NE, Cahn W, Hulshoff Pol HE, Schnack HG, Caspers E, Lemstra A, et al. Brain volumes as predictor of outcome in recent-onset schizophrenia: a multi-center MRI study. Schizophr Res 2003;64:41-52 https://doi.org/10.1016/S0920-9964(03)00018-5
- Turner JA, Smyth P, Macciardi F, Fallon JH, Kennedy JL, Potkin SG. Imaging phenotypes and genotypes in schizophrenia. Neuroinformatics 2006;4:21-49 https://doi.org/10.1385/NI:4:1:21
- Kruggel F, Turner J, Muftuler LT; Alzheimer's Disease Neuroimaging Initiative. Impact of scanner hardware and imaging protocol on image quality and compartment volume precision in the ADNI cohort. Neuroimage 2010;49:2123-2133 https://doi.org/10.1016/j.neuroimage.2009.11.006
- Fischl B, Salat DH, van der Kouwe AJ, Makris N, Segonne F, Quinn BT, et al. Sequence-independent segmentation of magnetic resonance images. Neuroimage 2004;23 Suppl 1:S69-S84
- Kruggel F. MRI-based volumetry of head compartments: normative values of healthy adults. Neuroimage 2006;30:1-11 https://doi.org/10.1016/j.neuroimage.2005.09.063
- Barnes J, Scahill RI, Boyes RG, Frost C, Lewis EB, Rossor CL, et al. Differentiating AD from aging using semiautomated measurement of hippocampal atrophy rates. Neuroimage 2004;23:574-581 https://doi.org/10.1016/j.neuroimage.2004.06.028
- Ashburner J, Friston KJ. Voxel-based morphometry--the methods. Neuroimage 2000;11:805-821 https://doi.org/10.1006/nimg.2000.0582
- Joo EY, Tae WS, Kim ST, Hong SB. Gray matter concentration abnormality in brains of narcolepsy patients. Korean J Radiol 2009;10:552-558 https://doi.org/10.3348/kjr.2009.10.6.552
- Thompson PM, Giedd JN, Woods RP, MacDonald D, Evans AC, Toga AW. Growth patterns in the developing brain detected by using continuum mechanical tensor maps. Nature 2000;404:190-193 https://doi.org/10.1038/35004593
- Shuter B, Yeh IB, Graham S, Au C, Wang SC. Reproducibility of brain tissue volumes in longitudinal studies: effects of changes in signal-to-noise ratio and scanner software. Neuroimage 2008;41:371-379 https://doi.org/10.1016/j.neuroimage.2008.02.003
- Ewers M, Teipel SJ, Dietrich O, Schönberg SO, Jessen F, Heun R, et al. Multicenter assessment of reliability of cranial MRI. Neurobiol Aging 2006;27:1051-1059 https://doi.org/10.1016/j.neurobiolaging.2005.05.032
- Jovicich J, Czanner S, Han X, Salat D, van der Kouwe A, Quinn B, et al. MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths. Neuroimage 2009;46:177-192 https://doi.org/10.1016/j.neuroimage.2009.02.010
- Han X, Jovicich J, Salat D, van der Kouwe A, Quinn B, Czanner S, et al. Reliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer. Neuroimage 2006;32:180- 194 https://doi.org/10.1016/j.neuroimage.2006.02.051
- Boyes RG, Gunter JL, Frost C, Janke AL, Yeatman T, Hill DL, et al. Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coils. Neuroimage 2008;39:1752-1762 https://doi.org/10.1016/j.neuroimage.2007.10.026
- Jovicich J, Czanner S, Greve D, Haley E, van der Kouwe A, Gollub R, et al. Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data. Neuroimage 2006;30:436-443 https://doi.org/10.1016/j.neuroimage.2005.09.046
Cited by
- Influence of Parameter Settings in Voxel-based Morphometry 8 : Using DARTEL and Region-of-interest on Reproducibility in Gray Matter Volumetry vol.54, pp.2, 2012, https://doi.org/10.3414/me14-01-0049
- Functional Brain Imaging with MR Scanner vol.73, pp.11, 2017, https://doi.org/10.6009/jjrt.2017_jsrt_73.11.1149
- Combining Segmented Grey and White Matter Images Improves Voxel-based Morphometry for the Case of Dilated Lateral Ventricles vol.17, pp.4, 2012, https://doi.org/10.2463/mrms.mp.2017-0127
- Depressive symptoms in Parkinson’s disease are related to decreased left hippocampal volume: correlation with the 15-item shortened version of the Geriatric Depression Scale vol.59, pp.3, 2012, https://doi.org/10.1177/0284185117719100
- SPMを用いたVBM解析における技術的注意点 vol.39, pp.4, 2012, https://doi.org/10.2463/jjmrm.2019-1678
- Neuroharmony: A new tool for harmonizing volumetric MRI data from unseen scanners vol.220, pp.None, 2012, https://doi.org/10.1016/j.neuroimage.2020.117127
- Influence of Mild White Matter Lesions on Voxel-based Morphometry vol.20, pp.1, 2021, https://doi.org/10.2463/mrms.mp.2019-0154