DOI QR코드

DOI QR Code

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong (Department of Conservative Dentistry, Kyungpook National University School of Dentistry) ;
  • Park, Sang-Shin (School of Mechanical Engineering, Yeungnam University)
  • 투고 : 2012.06.28
  • 심사 : 2012.10.04
  • 발행 : 2012.12.01

초록

Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

키워드

참고문헌

  1. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-351.
  2. Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995;21:146-151.
  3. Yun HH, Kim SK. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;95:228-233.
  4. Ha JH, Jin MU, Kim YK, Kim SK. Comparison of screw-in effect for several nickel-titanium rotary instruments in simulated resin root canal. J Korean Acad Conserv Dent 2010;35:267-272.
  5. Malueg LA, Wilcox LR, Johnson W. Examination of external apical root resorption with scanning electron microscopy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1996;82:89-93.
  6. Sjogren U, Hagglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod 1990;16:498-504.
  7. Smith CS, Setchell DJ, Harty FJ. Factors influencing the success of conventional root canal therapy-a five-year retrospective study. Int Endod J 1993;26:321-333.
  8. Swartz DB, Skidmore AE, Griffin JA Jr. Twenty years of endodontic success and failure. J Endod 1983;9:198-202.
  9. Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod 2000;26:161-165.
  10. Diemer F, Calas P. Effect of pitch length on the behavior of rotary triple helix root canal instruments. J Endod 2004;30:716-718.
  11. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, Pasqualini D. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod 2009;35:408-412.
  12. Berutti E, Negro AR, Lendini M, Pasqualini D. Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod 2004;30:228-230.
  13. Patino PV, Biedma BM, Liebana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 2005;31:114-116.
  14. Sung HJ, Ha JH, Kim SK. Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal. J Korean Acad Conserv Dent 2010;35:380-386.
  15. Di Fiore PM. A dozen ways to prevent nickel-titanium rotary instrument fracture. J Am Dent Assoc 2007;138: 196-201.
  16. Gulabivala K, Abdo S, Sherriff M, Regan JD. The influence of interfacial forces and duration of filing on root canal shaping. Endod Dent Traumatol 2000;16:166-174.
  17. Li UM, Lee BS, Shih CT, Lan WH, Lin CP. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 2002;28:448-451.
  18. Gabel WP, Hoen M, Steiman HR, Pink FE, Dietz R. Effect of rotational speed on nickel-titanium file distortion. J Endod 1999;25:752-754.
  19. Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 2001;27:772-774.
  20. Schrader C, Peters OA. Analysis of torque and force with differently tapered rotary endodontic instruments in vitro. J Endod 2005;31:120-123.

피인용 문헌

  1. Torsional and cyclic fatigue resistances of glide path preparation instruments: G-file and PathFile vol.36, pp.5, 2014, https://doi.org/10.1002/sca.21145
  2. ‘Screw-in’ tendency of rotary nickel-titanium files due to design geometry vol.48, pp.7, 2014, https://doi.org/10.1111/iej.12363
  3. Comparision of two different preparation protocol of Ni-Ti Rotary PathFile-ProTaper instruments in simulated s-shaped canals vol.72, pp.1, 2014, https://doi.org/10.3109/00016357.2013.805430
  4. Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation vol.104, pp.2, 2016, https://doi.org/10.1007/s10266-015-0199-0
  5. Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation vol.11, pp.8, 2016, https://doi.org/10.1371/journal.pone.0160815
  6. Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study vol.38, pp.6, 2016, https://doi.org/10.1002/sca.21304
  7. comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals vol.42, pp.4, 2017, https://doi.org/10.5395/rde.2017.42.4.282
  8. study vol.42, pp.4, 2017, https://doi.org/10.5395/rde.2017.42.4.316
  9. Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature pp.01432885, 2017, https://doi.org/10.1111/iej.12846
  10. Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation vol.39, pp.4, 2014, https://doi.org/10.5395/rde.2014.39.4.270
  11. Effect of repetitive pecking at working length for glide path preparation using G-file vol.40, pp.2, 2015, https://doi.org/10.5395/rde.2015.40.2.123
  12. Safe root canal preparation using reciprocating nickel-titanium instruments vol.40, pp.3, 2015, https://doi.org/10.5395/rde.2015.40.3.253
  13. Influence of a glide path on the dentinal crack formation of ProTaper Next system vol.40, pp.4, 2015, https://doi.org/10.5395/rde.2015.40.4.286
  14. Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files vol.51, pp.9, 2018, https://doi.org/10.1111/iej.12911
  15. Comparison of glide paths created with K-files, PathFiles, and the ProGlider file, and their effects on subsequent WaveOne preparation in curved canals vol.18, pp.1, 2018, https://doi.org/10.1186/s12903-018-0614-3
  16. Evaluation of selected mechanical properties of NiTi rotary glide path files manufactured from controlled memory wires vol.37, pp.4, 2018, https://doi.org/10.4012/dmj.2017-276
  17. Real-time dynamic torque values and axial forces during preparation of straight root canals using three different endodontic motors and hand preparation pp.01432885, 2019, https://doi.org/10.1111/iej.12980
  18. Effective Establishment of Glide-Path to Reduce Torsional Stress during Nickel-Titanium Rotary Instrumentation vol.12, pp.3, 2019, https://doi.org/10.3390/ma12030493
  19. Glide Path Management with Single- and Multiple-instrument Rotary Systems in Curved Canals: A Micro-Computed Tomographic Study vol.41, pp.11, 2015, https://doi.org/10.1016/j.joen.2015.07.014
  20. Torsional Performance of ProTaper Gold Rotary Instruments during Shaping of Small Root Canals after 2 Different Glide Path Preparations vol.43, pp.3, 2012, https://doi.org/10.1016/j.joen.2016.10.034
  21. Comparing the Centering Ability of Different Pathfinding Systems and Their Effect on Final Instrumentation by Hyflex CM vol.43, pp.11, 2017, https://doi.org/10.1016/j.joen.2017.05.022
  22. Cyclic Fatigue Resistance of Novel Glide Path Instruments with Different Alloy Properties and Kinematics vol.44, pp.9, 2012, https://doi.org/10.1016/j.joen.2018.05.013
  23. Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys vol.33, pp.None, 2012, https://doi.org/10.1590/1807-3107bor-2019.vol33.0097
  24. Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files vol.44, pp.2, 2012, https://doi.org/10.5395/rde.2019.44.e22
  25. Comparison of Screw-In Forces during Movement of Endodontic Files with Different Geometries, Alloys, and Kinetics vol.12, pp.9, 2012, https://doi.org/10.3390/ma12091506
  26. Force and vibration generated in apical direction by three endodontic files of different kinematics during simulated canal preparation: An in vitro analytical study vol.233, pp.8, 2012, https://doi.org/10.1177/0954411919854574
  27. Comparison of torque, force generation and canal shaping ability between manual and nickel-titanium glide path instruments in rotary and optimum glide path motion vol.108, pp.2, 2012, https://doi.org/10.1007/s10266-019-00455-1
  28. Ex-Vivo Comparison of Torsional Stress on Nickel–Titanium Instruments Activated by Continuous Rotation or Adaptive Motion vol.13, pp.8, 2020, https://doi.org/10.3390/ma13081900
  29. Comparative Evaluation of Cleaning Efficiency and Apical Extrusion of Debris Using Two Pediatric Rotary Endodontic Files: An In Vitro Study vol.14, pp.2, 2012, https://doi.org/10.5005/jp-journals-10005-1918
  30. Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review vol.11, pp.7, 2012, https://doi.org/10.3390/app11073079
  31. Influence of rotational speed on torque/force generation and shaping ability during root canal instrumentation of extracted teeth with continuous rotation and optimum torque reverse motion vol.54, pp.9, 2012, https://doi.org/10.1111/iej.13485
  32. Shot peening increases resistance to cyclic fatigue fracture of endodontic files vol.11, pp.1, 2012, https://doi.org/10.1038/s41598-021-92382-x
  33. Body temperature fatigue behaviour of reciprocating and rotary glide path instruments in sodium hypochlorite solutions alone or combined with etidronate vol.47, pp.3, 2021, https://doi.org/10.1111/aej.12504
  34. Optimum glide path motion is safer than continuous rotation of files in glide path preparation vol.47, pp.3, 2012, https://doi.org/10.1111/aej.12519
  35. Comparison of canal transportation and centering ability of manual K-files and reciprocating files in glide path preparation: a micro-computed tomography study of constricted canals vol.21, pp.1, 2012, https://doi.org/10.1186/s12903-021-01440-3
  36. Root canals shaped by nickel-titanium instrumentation with automated computerized numerical control systems vol.21, pp.1, 2012, https://doi.org/10.1186/s12903-021-01841-4
  37. An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective-An Overview vol.8, pp.12, 2012, https://doi.org/10.3390/bioengineering8120218
  38. Shaping ability of ProTaper Gold and WaveOne Gold nickel-titanium rotary instruments in simulated S-shaped root canals vol.17, pp.1, 2022, https://doi.org/10.1016/j.jds.2021.08.008