참고문헌
- Bulow-Hube, H. (2001). Energy-efficient window systems: Effects on energy use and daylight in buildings. Ph. D. dissertation, Lunds University, Sweden.
- Chauvel, P., Collins, J.B. Dogniaux, R. Longmore, J. (1982). Glare from windows: current views of problem. Lighting Research and Technology 14(1), 31-46. https://doi.org/10.1177/096032718201400103
- Guillemin, A. and Morel, S. (2002). An energy-efficient controller for shading devices self-adapting to the user wishes. Building and Environment, 37(11), 1091-1097. https://doi.org/10.1016/S0360-1323(01)00113-5
- Kim, B., & Kim, J. (2006). Automatic control strategy of venetian blind for improvement of environmental performance in office buildings. Conference Proceeding of the Korea Institute of Ecological Architecture and Environment, 237-241.
- Kim, J. (2007). Automatic control strategy of venetian blind for improvement of environmental performance in office buildings. Ph. D. dissertation, Seoul National University, Seoul.
- Koo, S. (2011). Optimum Blind Control to Maximize Solar Heat Gain Preventing Glare on Workplane. Ph. D. dissertation, Seoul National University, Seoul.
- Koo, S., Yeo, M., & Kim, K. (2010). Automated blind control to maximize the benefits of daylight in buildings. Building and Environment, 45(6), 1508-1520. https://doi.org/10.1016/j.buildenv.2009.12.014
- Ku, H. (2009). Automated blind control algorithm from control frequency based on user preference. Master's thesis, Seoul National University, Seoul.
- Lindsay, C.R.T. & Littlefair, P.J. (1992). Occupant Use of Venetian Blinds in Offices. Building Research Establishment (BRE).
- Osterhaus, W.K.E. (2005). Discomfort glare assessment and prevention for daylight applications in office environments. Solar Energy, 79(2), 140-158. https://doi.org/10.1016/j.solener.2004.11.011
- Paik, J., Kim, J., Yeo, M., & Kim, K. (2006). A study on the occupants use of the blinds in office building. Journal of the Architectural Institute of Korea: Planning & Design, 22(12), 311-318.
- Raja, I.A., Nicol, J.F., McCartney, K.J., & Humphreys, M.A. (2001). Thermal comfort: Use of controls in naturally ventilated buildings. Energy and Buildings, 33(3), 235-244. https://doi.org/10.1016/S0378-7788(00)00087-6
- Rea, M. (1984). Window blind occlusion: a pilot study. Building and Environment, 19(2), 133-137. https://doi.org/10.1016/0360-1323(84)90038-6
- Reinhart, C. F. (2004). Lightswitch-2002: a model for manual and automated control of electric lighting and blinds. Solar Energy, 77(1), 15-28. https://doi.org/10.1016/j.solener.2004.04.003
- Tzempelikos, A. (2008). The impact of venetian blind geometry and tilt angle on view, direct light transmission and interior illuminance. Solar Energy, 82(12), 1172-1191. https://doi.org/10.1016/j.solener.2008.05.014
- 金會瑞. (1986). ル一バ一型日射遮蔽裝置の採光特性に關する硏究. 博士論文, 國立京都大學.
피인용 문헌
- Automated Blind Control Strategy to Minimize Occupant's Distractions vol.33, pp.2, 2013, https://doi.org/10.7836/kses.2013.33.2.084
- Optimized control algorithm for automated Venetian blind system considering solar profile variation in buildings vol.23, pp.6, 2014, https://doi.org/10.1177/1420326X13487918
- : Blind control simulator and method with a consideration of adjacent buildings vol.24, pp.1, 2015, https://doi.org/10.1177/1420326X13500976