DOI QR코드

DOI QR Code

Evaluation of the Applicability of Existing Design Formula for Seismic Isolation to Nuclear Power Plants

원자력발전소 면진적용을 위한 기존 설계식의 적용성 검토

  • Kim, Hyun-Uk (Plant Construction & Engineering Office of KHNP Central Research Institute)
  • 김현욱 (한수원 중앙연구원 플랜트건설기술연구소)
  • Received : 2012.09.28
  • Accepted : 2012.11.20
  • Published : 2012.12.31

Abstract

Involved in a research for the application of seismic isolation to the nuclear industry, this study evaluates firstly the responses of seismic isolation system considering general ranges of structural period and damping ratio by using preliminary design formula. Secondly, coupling effects of input motions were evaluated to find out appropriate conditions of excitations and effect of the iteration for calculating yield displacement of lead core was also assessed in terms of response of a seismically isolated structure. Finally, the results of preliminary design calculation were compared with those of dynamic analysis and the propriety of the formula was evaluated and appropriate ranges of reduction factor were also suggested from the results.

Keywords

References

  1. Hyun-Uk Kim, Dong-Hee Park, "A Parametric Study on Preliminary Design of the Seismic Isolation System for NPP," Proceedings of EESK Conference, Earthquake Engineering Society of Korea, 219-222, 2012.
  2. Jong-Hak Kim, Jong-Bo Lee, Sang-Hoon Noh, A Technical Review Report of Seismic Analysis and Enveloped Site Design in Shin-Kori NPP #3&4, Korea Hydro and Nuclear Power, 18-19, 2008.
  3. Architectural Institute of Korea, Korea Building Code, 2009
  4. Korean Society of Civil Engineers, Korea Bridge Design Code, 997-1006, 2008..
  5. American Association of State Highway and Transportation Officials, Guide Specifications for Seismic Isolation Design 3rd Edition, 15-16, 2010.
  6. American Society of Civil Engineers, ASCE/SEI 7-10 : Minimum Design Loads for Buildings and Other Structures Ch.17. Seismic Design Requirements for Seismically Isolated Structures, 165-177, 2010.
  7. Bozidar Stojadinovic, Technical Considerations for Seismic Isolation of Nuclear Facilities, US NRC Report, 46-62, 2011.
  8. Ronald L. Mayes and Farzad Naeim, The Seismic Design Handbook 2nd Edition Ch. 14 Design of Structures with Seismic Isolation, 2001
  9. Gomase O.P., Bakre S.V., "Performance of Non-Linear Elastomeric Base-Isolated Building Structure," J. of Civil & Structural Eng., IPA Vol.2 (1), 280-289, 2011.
  10. Japan Electric Association Guide, JEAG 4614-2000 : Technical Guidelines on Seismic Base Isolation Systems for Structural Safety and Design of Nuclear Power Plants, 2000.
  11. Japan Nuclear Energy Safety, Regulatory Guideline for Reviewing Seismic Isolation Structure, JNES-SS-1001, 2010.
  12. Mokha, A. S., Constantinou, M. C., and Reinhorn, A. M., "Verification of friction model of Teflon bearings under triaxial load.," Journal of Structural Engineering, 119(1):240-261, 1993. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:1(240)
  13. National Institute of Building Science, NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures(FEMA 450) Ch.13. Seismically Isolated Structure Design Requirements, 215-232, 2003.
  14. National Institute of Building Sciences, NEHRP Recommended Provisions(FEMA 451), 11-1-11-34, 2006.
  15. Ryan, K. L., Kelly, J. M and Chopra, A. K., "Nonlinear model for lead-rubber bearings including axial-load effects," Journal of Engineering Mechanics, Vol. 131, No. 12, 1270-1278, 2005. https://doi.org/10.1061/(ASCE)0733-9399(2005)131:12(1270)
  16. US NRC, Regulatory Guide 1.60 - Design Response Spectra for Seismic Design of Nuclear Power Plants, 1973.
  17. US NRC, Seismic Design Parameters(Rev 3), NUREG-0800 SRP 3.7.1, 2007.
  18. US NRC, Regulatory Guide 1.208 - A Performance-Based Approach to Define the Site-Specific Earthquake Ground Motion, 2007.

Cited by

  1. Behavior Analysis of a Seismically Isolated NPP Structure by Varying Seismic Input Generation Method and Strong Ground Motion Duration vol.17, pp.4, 2013, https://doi.org/10.5000/EESK.2013.17.4.187
  2. Characteristics of Earthquake Responses of an Isolated Containment Building in Nuclear Power Plants According to Natural Frequency of Soil vol.17, pp.6, 2013, https://doi.org/10.5000/EESK.2013.17.6.245
  3. Multi-Step Analysis of Seismically Isolated NPP Containment Structures with Lead-Rubber Bearings vol.18, pp.6, 2014, https://doi.org/10.5000/EESK.2014.18.6.261
  4. Comparison of Seismic Responses of Seismically Isolated NPP Containment Structures using Equivalent Linear- and Nonlinear-Lead-Rubber Bearing Modeling vol.19, pp.1, 2015, https://doi.org/10.5000/EESK.2015.19.1.001