DOI QR코드

DOI QR Code

Analysis on Parameter Detuning of Induction Motor Drives in Constant Torque Region

일정토크영역에서 유도전동기 고정자자속기준제어의 파라미터 비동조 영향 분석

  • Shin, Myoung-Ho (Dept. of Electrical and Information Engineering, Seoul Nat'l Univ. of Science and Technology)
  • 신명호 (서울과학기술대학교 전기정보공학과)
  • Received : 2012.09.10
  • Accepted : 2012.10.08
  • Published : 2012.11.30

Abstract

It is well known that the stator-flux-oriented induction motor drives are not dependent on parameter detuning in constant torque region except low speed range. This paper presents parameter detuning effects of stator-flux-oriented induction motor drives in constant torque region. The detuning effects of stator resistance, rotor resistance and rotor leakage inductance are analyzed.

Keywords

References

  1. X. X. Xu, R. D. Doncker, and D. W. Novotny, "A stator flux oriented induction machine drive," in Proc. IEEE PESC''88, 1988, pp. 870-876.1992.
  2. Myoung-Ho Shin and Dong-Seok Hyun, "Online Identification of Stator Transient Inductance in Rotor-Flux-Oriented Induction Motor Drive", IEEE Trans. IE, vol. 54, no.4, pp.2018-2023, 2007.
  3. Myoung-Ho Shin, "Analysis on Parameter Detuning of Induction Motor Drives in Field Weakening Region", Journal of KIIEE, vol. 24, no. 9, pp. 118-123, 2010. https://doi.org/10.5207/JIEIE.2010.24.9.118
  4. Myoung-Ho Shin, Dong-Seok Hyun, Soon-Bong Cho, and Song-Yul Choe, "An Improved Stator Flux Estimation for Speed Sensorless Stator Flux Orientation Control of Induction Motors", IEEE Trans. PE, vol. 15, no. 2, pp. 312-318, 2000.

Cited by

  1. An Analysis on a Torque Error of a 3-Phase Induction Motor due to Simplified Equivalent Circuit vol.28, pp.1, 2014, https://doi.org/10.5207/JIEIE.2014.28.1.045