Abstract

When we design the grounding grid, dangerous voltage ANSI/IEEE Std. 80 method has been commonly used in the domestic area. However, the suitability of the ground rules for the design environment available. However, the suitability of the ground rules for the design environment available. In this paper, sticks according to the electrode conductor in combination with the mesh in order to design the ground by the IEEE Std.80 was designed. So in this paper, we examined of IEEE Std. 80 touch voltage method marginal utility and we induced for those problems by comparison between IEEE Std. 80 touch voltage value and simulation experimentation value. Furthermore, this paper presents a new design grounding system method that complements the IEEE Std. 80 method.

Keywords

References

  1. ANSI/IEEE Std. 80-1986, "IEEE Guide for Safety in AC Substation Grounding", Institute of Electrical and Electronics Engineers, Inc, New York. 1986
  2. ANSI/IEEE Std. 80-2000, "IEEE Guide for Safety in AC Substation Grounding", Institute of Electrical and Electronics Engineers, Inc, New York. 2000
  3. ANSI/IEEE Std. 80-1983, "IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System", Institute of Electrical and Electronics Engineers, Inc., New York, 1983
  4. ANSI/IEEE Std. 142-1991, "IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems", Institute of Electrical and Electronics Engineers, Inc., New York, 1991
  5. ANSI/IEEE Std. 142-1991, "IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage From a Power Fault", Institute of Electrical and Electronics Engineers, Inc., New York, 1996.
  6. 김재철외 , IEC 60364 기반 접지계통 비교 분석, 한국조명전기설비학회 논문지, Vol. 24, No. 1, 2010 https://doi.org/10.5207/JIEIE.2010.24.1.056
  7. "내선규정", 대한전기협회, 2000
  8. "전기설비기술기준", 산업자원부, 2001
  9. 고교건언저, 이형수역, 동일출판사, 接地設計入聞 1993
  10. W. C. Hart and E. W. Malone, Lightning and Lightning Protection, Interference Control Technologies, Gainesville, Virginia, pp.3.69-3.76, 1988.
  11. T. Takahashi, "A Part of Grounding for Lightning Protection Technique", J. of the Institute of Electrical Installation Engineers of Japan, Vol.9, pp.671-676, 1889
  12. P. R. Tompson, "Lightning Protection of SCADA and Telemetry Systems", Proc. of 2nd Annual Technical Conference on Lightning Protection & Earthing, pp.1-6, 1994
  13. 장근철, "심매설 봉상 접지전극의 과도 임피던스 특성", 인하대학교, 2004
  14. 심용식, "봉상접지전극과 Mesh접지전극의 매설깊이 변화에 따른 위험전압 분석에 관한 연구", 한국조명전기설비학회 논문지, Vol.25, No.4, 2011 https://doi.org/10.5207/JIEIE.2011.25.4.038
  15. 신복성외, 위험전압 검토에 따른 개선된 접지설비 모델, 한국조명전기설비학회 논문지, Vol. 22, No.4, 2008 https://doi.org/10.5207/JIEIE.2008.22.4.068
  16. 심용식외, 메시접지극의 내부도체 배치에 따른 개선된 메시접지극 모델, 한국조명전기설비학회 논문지, Vol. 24, No.6, 2010 https://doi.org/10.5207/JIEIE.2010.24.6.060
  17. 손이조, IEC 60364 전기설계감리 시공가이드북, 기다리, 2009
  18. 이복희외, "접지의 핵심 기초 기술", 의제, 2002
  19. 김태훈외, "접지제원 변화에 따른 사선 메쉬접지의 특성변화", 한국조몀전기설비학회논문집, pp347-350, 2009
  20. 다카하시 다케히코, 정종욱 옮김, 일본 옴사-성안당, 접지.등전위 본딩 설계 실무지식, 2008.
  21. 손이조, (주)세홍이엔씨, "전력계통해석 프로그램"

Cited by

  1. Grounding Grid Design Considering the Dangerous Voltage of Multi-layered Model in the Constrained Sites vol.62, pp.3, 2013, https://doi.org/10.5370/KIEEP.2013.62.3.139