Acknowledgement
Supported by : 부경대학교
References
- C. Passmann and H. Ermert, "A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics", IEEE Trans. on UFFC, vol. 43, no. 4, pp. 545-552, 1996. https://doi.org/10.1109/58.503714
- G. S. Kino, Acoustic waves -devices, imaging, & analog signal processing-, Prentice-Hall Inc., Englewood Cliffs, 1987.
- T. A. Ritter, T. R. Shrout, R. Tutwiler, and K. K. Shung, "A 30-MHz piezo-composite ultrasound array for medical imaging applications", IEEE Trans. on UFFC, vol. 49, no. 2, pp. 217-230, 2002. https://doi.org/10.1109/58.985706
- M. Robert. G. Molingou, K. Snook, J. Cannata, and K. K. Shung, "Fabrication of focused poly (vinylidene fluoridetrifluoroethylene) P (VDF-TrFE) copolymer 40-50 MHz ultrasound transducers on curved surfaces", Journal of Applied Physics, vol. 96, no. 1, pp. 252-256, 2004. https://doi.org/10.1063/1.1760233
- J. A. Ketterling, F. L. Lizzi, O. Aristizabal, and D. H. Turbull. "Design and fabrication of a 40-MHz annular array transducer", IEEE Trans. on UFFC, vol. 52, no. 4, pp. 672- 681, 2005. https://doi.org/10.1109/TUFFC.2005.1428050
- A. Denoyer, F. Ossant, B. Arbeille, F. Fetissof, F. Patat, L. Pourcelot, and P. J. Pisella, "Very-high-frequency ultrasound corneal imaging as a new tool for early diagnosis of ocular surface toxicity in rabbits treated with a preserved glaucoma drug", Ophthalmic Res., vol. 40, pp. 298-308, 2008. https://doi.org/10.1159/000134928
- F. S. Foster, C. J. Pavlin, G. R. Lockwood, L. K. Ryan, K. A. Harasiewicz, L. R. Berube, and A. M. Rauth, "Principles and applications of ultrasound backscatter microscopy", IEEE Trans. on UFFC, vol. 40, no. 5, pp. 608-617, 1993. https://doi.org/10.1109/58.238115
- F. S. Foster, C. J. Pavlin, K. A. Harasiewicz, D. A. Christopher, and D. H. Turnbull, "Advanced in ultrasound biomicroscopy", Ultrasound in Med. & Bilo., vol. 26, no. 1, pp. 1-27, 2000. https://doi.org/10.1016/S0301-5629(99)00096-4
- http://www.capolabs.com/index.htm
- R. Krimholtz, D.A. Leedom, and G.L. Matthaei, "New equivalent circuit for elementary piezoelectric transducers", Electron. Lett., vol. 6, pp. 398-399, 1970. https://doi.org/10.1049/el:19700280
- S. Sherrit, S.P. Leary, B.P. Dolgin, and Y. Bar-Cohen "Comparison of the Mason and KLM equivalent circuits for piezoelectric resonators in the thickness mode", 1999 IEEE Ultrasonics Symposium, pp. 921-926, 1999.
- 양정화, 이경성, 강관석, 팽동국, 최민주, "초음파프로브의 결함이 B-모드 영상의 공간 분해능에 미치는 영향," 한국음향학회 2009년도 춘계학술발표대회 논문집, 제28권, 1(s)호, 176-179쪽, 2009.
- 최광윤, 하강렬, 김무준, 김정순, 양정화, 강관석, 최민주, "의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향," 한국음향학회지, 제29권, 8호, 476-482쪽, 2010.
Cited by
- Effect of a Bonding Layer between Electrodes on the Performance of a -Mode PVDF Ultrasound Transducer vol.33, pp.2, 2014, https://doi.org/10.7776/ASK.2014.33.2.102