DOI QR코드

DOI QR Code

Micro pH Sensor Using Patterned Hydrogel with pH Indicators

  • Jang, Ji-Sung (School of Electrical Engineering, Seoul National Unversity) ;
  • Kwon, Sung-Hoon (School of Electrical Engineering, Seoul National Unversity)
  • Received : 2011.06.30
  • Published : 2011.07.31

Abstract

This paper presents a study into pH Indicator-Embedded hydrogel micro-particles which are encoded various shapes according to the captured indicator. We incorporate various pH indicators into a photo-curable hydrogel, PEG-DA(Poly(ethylene glycol) diacrylate). Using the latest fluidic lithography techniques, we can easily fabricate variously patterned hydrogel particles based on in-situ photopolymerization of the PEG-DA in a micro-fluidic channel. The shape of the particle is related to the pH indicator inside the particle. We demonstrate that the micro pH sensors change their colors according to the pH levels. The micro pH sensors have various characteristics that are related to the curing time, particle size, etc. By changing these conditions, we can adjust the long term stability and reaction time of the hybrid micro pH sensors.

Keywords

References

  1. Kyosuke Shinohara, Yasuhiko Sugii, et al., "Measurement of pH field of chemically reacting flow in microfluidic devices by laser-induced fluorescence", Meas. Sci. Technol, vol. 15, no. 5, pp. 955-960, 2004. https://doi.org/10.1088/0957-0233/15/5/025
  2. Go Nishimura, Yasuhiro Shiraishi, and Takayuki Hirai , "A fluorescent chemosensor for wide-range pH detection", Chem. Commun., no. 42, pp. 5313-5315, 2005.
  3. Norbert Klauke, Paul Monaghan, et al., "Characterisation of spatial and temporal changes in pH gradients in microfluidic channels using optically trapped fluorescent sensors", Lab Chip, vol. 6, no. 6, pp. 788-793, 2006. https://doi.org/10.1039/b517237c
  4. Raoul Kopelman, Hiroshi Masuhara, Keiji Sakaki, and Zhong-Yon Shi, "Three-dimensional pH microprobing with an optically-manipulated fluorescent particle", Chem. Lett., vol. 25, no. 2, pp.141-142, 1996. https://doi.org/10.1246/cl.1996.141
  5. H. Maruyama, T. Hukuda, et al., "On-chip pH measurement using functionalized gel-microbeads positioned by optical tweezers", Lab Chip, vol. 8, no. 2, pp. 346-351, 2008. https://doi.org/10.1039/b712566f
  6. M. Nakao, S. Inoue, R. Oishi, T. Yoshinobu, and H. Iwasaki, "Observation of microorganism colonies using a scanning-laser-beam pH-sensing microscope", Journal of Fermentation and Bioengineering, vol. 79, no. 2, pp. 163-166, 1995. https://doi.org/10.1016/0922-338X(95)94085-6
  7. D. Dendukuri, D. C. Pregibon, J. Collins, T. A. Hatton, and P. S. Doyle, "Continuous-flow lithography for high-throughput microparticle synthesis," Nature Materials, vol. 5, no. 5, pp . 365-369, 2006. https://doi.org/10.1038/nmat1617
  8. S. E. Chung, W. Park, H. Park, K. Yu, N. Park, and S. Kwon, "Optofluidic maskless lithography system for real-time synthesis of photopolymerized microstructures in microfluidic channels", Applied Physics Letters, vol. 91, no. 4, 2007.
  9. G. M. Whitesides, E. Ostuni, S. Takayama, X. Y. Jiang, and D. E. Ingber, "Soft lithography in biology and biochemistry," Annual Review of Biomedical Engineering, vol. 3, pp. 335-373, 2001. https://doi.org/10.1146/annurev.bioeng.3.1.335