Abstract
Precast culvert system is generally constructed with a series of process such as excavation, ground mitigation, placement of culverts, anti-leakage packing between adjacent culverts, post-tensioning for PS strands and backfilling. In this process inappropriate ground mitigation often causes differential settlement and, correspondingly, makes water-leakage to be occurred between adjacent boxes. This study was performed to understand the behavioral characteristics of recently proposed precast foundation plate to support precast culvert system through on-site pilot construction. The gap between two adjacent culverts, increment of earth pressure at the bottom of culvert, vertical settlement of top of the culverts were monitored using various sensors. The monitoring results showed that the proposed foundation plate provides better culvert system in the points of less gap development, earth pressure and settlement at the adjacent of two culverts.
PC 암거는 터파기, 하부지반 처리, 암거 거치, 상호접합면에 누수방지용 패킹재 부착, PS 강선의 긴장을 통한 상호박스 접합, 되메우기 등의 일련의 과정으로 시공되어진다. 이 때 부적절한 하부지반 처리는 박스간 상호 부등침하를 야기할 수 있으며 결과적으로 지하수의 와류 및 내부유수의 누수를 발생시키게 된다. 본 연구에서는 하부지반이 연약한 경우 PC 암거 접합부의 부등침하를 저감하기 위하여 개발된 PC 기초판과 일체화된 암거의 거동을 현장 시험시공을 통해 분석하였다. 암거의 거동은 접합부에서 암거간의 벌어짐, 하부지반에 작용하는 토압 증가량, 암거 상부의 침하량 계측을 통해 분석되었으며, 분석결과로부터 PC 기초판과 일체화된 암거가 일반적인 시공방법인 PS 강선의 인장으로 체결된 암거에 비하여 침하 및 접합부에서 벌어짐이 적게 발생하는 것으로 나타났다.