DOI QR코드

DOI QR Code

Analysis of Failure Probabilities of Pipes in Nuclear Power Plants due to Stress Corrosion Cracking

원자력 발전소 배관의 응력부식에 의한 파손확률 해석

  • Received : 2010.05.24
  • Accepted : 2011.03.19
  • Published : 2011.04.30

Abstract

The failure probabilities of pipes in nuclear power plants due to stress corrosion are obtained using the P-PIE program, which is developed for evaluating failure probability of pipes based on the existing PRAISE program. Leak, big leak and LOCA(loss of coolant accident) probabilities are calculated as a function of operating time for several pipes in a domestic nuclear plant. The sensitivity analysis is also performed to find out the important parameters for the failure of pipes due to stress corrosion. The results show that the steady state oxygen concentration and steady state temperature are important parameters and failure probability is very low when the oxygen concentration is maintained according to the regulation.

Keywords

Acknowledgement

Supported by : 충북대학교

References

  1. KINS/GR-359, 원자력 안전규제 기술개발 : 원전기기건전성 평가 규제 기술 개발, 2006.
  2. USNRC NUREG/BR-0303, Guidance for Performance-Based Regulation, 2002.
  3. USNRC SECY-98-144, Risk-Informed and Performance-Based Regulation, 1998.
  4. EMT TR-98-4-1, D.O. Harris and D. Dedhia, "Win-PRAISE 98 : PRAISE Code in Windows", 1998.
  5. 박재학, 이재봉, 최영환, "원전배관의 파손확률평가를 위한 P-PIE 프로그램의 개발", 한국안전학회지, 제25권, 제6호, pp. 1-8, 2010.
  6. 박재학, "확률론적 배관 건전성 평가 프로그램 개발", 원자력안전기술원 보고서, KINS/HR-991, 2010.