DOI QR코드

DOI QR Code

Change of Refractive Index of Air in X-band due to Atmospheric Humidity, Temperature and Pressure measured by GB-SAR Interferometry

GB-SAR 간섭기법으로 측정된 X-밴드 대기 굴절률의 상대습도, 기온 및 기압에 따른 변화

  • Lee, Jae-Hee (Department of Geophysics, Kangwon National University) ;
  • Lee, Hoon-Yol (Department of Geophysics, Kangwon National University) ;
  • Cho, Seong-Jun (Mineral Resources Research Division, Korea Institute of Geoscience and Mineral Resources) ;
  • Sung, Nak-Hoon (Mineral Resources Research Division, Korea Institute of Geoscience and Mineral Resources) ;
  • Kim, Kwang-Eun (Mineral Resources Research Division, Korea Institute of Geoscience and Mineral Resources)
  • 이재희 (강원대학교 지구물리학과) ;
  • 이훈열 (강원대학교 지구물리학과) ;
  • 조성준 (한국지질자원연구원 광물자원연구본부) ;
  • 성낙훈 (한국지질자원연구원 광물자원연구본부) ;
  • 김광은 (한국지질자원연구원 광물자원연구본부)
  • Received : 2011.03.04
  • Accepted : 2011.03.19
  • Published : 2011.04.30

Abstract

In this paper, we analyzed the phase change of 5-triangular trihedral comer reflectors by using X-band Ground-Based Synthetic Aperture Radar (GB-SAR) system. Each reflector was set as a stationary target at a different distance from the system. We obtained total 123 full-polarization images during 40 hours continuously at 20 minute interval. Results of SAR interferometric analysis showed phase changes of maximum 2 radians and followed similar pattern with atmospheric data. Through a GB-SAR phase formula that includes refractive index in the air, we performed regression analysis for refractive index as a function of atmospheric humidity, temperature and pressure. As a result, refractive index of air in X-band showed relatively high coefficient of determination with humidity and temperature (0.72 and 0.76 on average, respectively) but not so with pressure (0.34). The refractive index of air in X -band changed by 3.14\;{\times}\;10^{-5}$ during the measuring time with a humidity range of 50% ~ 90% and a temperature range of $-1^{\circ}C$ ~ $9^{\circ}C$. We expect that a total expression of refractive index of air including humidity, temperature and pressure can be calculated when more extensive data would be collected at various atmospheric conditions.

이 논문은 X-밴드 Ground-Based Synthetic Aperture Radar (GB-SAR) 시스템을 이용하여 5개의 삼각삼면반사체(triangular trihedral corner reflector)의 시간에 따른 위상변화를 분석하였다. 각각의 반사체는 시스템으로부터의 거리를 다르게 설정하여 고정시켰고 모든 편파에 대한 영상을 20 분 간격으로 123 회, 총 40 시간 동안 연속 측정하였다. SAR 간섭기법(interferometry)을 이용한 분석 결과 반사체는 고정된 상태임에도 불구하고 시간에 따라 최대 2 radian의 위상차가 나타났으며 기상요소와 유사한 추세를 보였다. 대기 중 굴절률을 고려한 GB-SAR 위상관계식을 통하여 대기 중 습도, 기온 및 기압의 변화에 따른 마이크로파 굴절률의 변화 양상을 회귀분석을 통하여 살펴보았다. 그 결과 X-밴드의 굴절률은 습도 및 기온과 비교적 높은 선형적 관계를 보였으나(평균 결정계수 각각 0.72, 0.76) 기압과는 그렇지 않았다(결정계수 0.34). 실험 기간 동안 습도는 약 50 %에서 90 %까지, 기온은 $-1^{\circ}C$에서 $9^{\circ}C$까지 변하였으며 X-밴드 굴절률의 변화는 약 $3.14{\times}10^{-5}$였다. 향후 보다 다양한 기상조건에서 실험이 이루어진다면 습도, 기온 및 기압 조건에 따른 굴절률의 포괄적 관계식을 유추할 수 있을 것으로 기대된다.

Keywords

References

  1. 이재희, 이훈열, 조성준, 성낙훈, 김정호, 2010. GBSAR 간섭기법을 이용한 반사체의 인위적 변위탐지 및 대기습도보정, 대한원격탐사학회지, 26 (2):123-131 https://doi.org/10.7780/kjrs.2010.26.2.123
  2. 이훈열, 조성준, 성낙훈, 김정호, 2007a. GB-SAR의 개발(I):시스템 구성과 간섭기법, 대한원격탐사학회지, 23(4):237-245. https://doi.org/10.7780/kjrs.2007.23.4.237
  3. 이훈열, 조성준, 성낙훈, 김정호, 2007b. GB-SAR의 개발(II):영상화 기법, 대한원격탐사학회지, 23(4):247-256. https://doi.org/10.7780/kjrs.2007.23.4.247
  4. Leva, D., G. Nico, D. Tarchi, J. F. Guasch, and J. Sieber, 2003. Temporal analysis of a Ground- Based SAR interferometry, IEEE Transactions on Geoscience and Remote Sensing, 41(4):745-752. https://doi.org/10.1109/TGRS.2003.808902
  5. Luzi, G., M. Pieraccini, D. Mecatti, L. Noferini, G. Guidi, F. Moia, and C. Atzeni, 2004. Ground- Based Radar interferometry for landslides monitoring: Atmospheric and instrumental decorrelation sources on experimental data, IEEE Transactions on Geoscience and Remote Sensing, 42(11):2454-2466. https://doi.org/10.1109/TGRS.2004.836792
  6. Luzi, G., M. Pieraccini, D. Mecatti, L. Noferini, G. Macaluso, A. Tamburini and C. Atzeni 2007. Monitoring of an Alpine glacier by means of Ground-Based SAR interferometry, IEEE Transactions on Geoscience and Remote Sensing, 4(3):495-499. https://doi.org/10.1109/LGRS.2007.898282
  7. Noferini, L., M. Pieraccini, D. Mecatti, G. Luzi, C. Atzeni, A. Tamburini, and M. Broccolato, 2005. Permanent Scatterers analysis for atmospheric correction in Ground-Based SAR interferometry, IEEE Transactions on Geoscience and Remote Sensing, 43(7):1459-1471. https://doi.org/10.1109/TGRS.2005.848707
  8. Noferini, L., M. Pieraccini, D. Mecatti, G. Macaluso, C. Atzeni, M. Mantovani, G. Marcato, A. Pasuto, S. Silvano and F. Tagliavini, 2007. Using GB-SAR technique to monitor show moving landslide, Engineering Geology, 95(3- 4):88-98. https://doi.org/10.1016/j.enggeo.2007.09.002
  9. Pieraccini, M., D. Mecatti, L. Noferini, G. Luzi, G. Franchioni, and C. Atzeni, 2002. SAR interferometry for detecting the effects of earthquakes on buildings, NDT&E International, 35(2002):615-625 https://doi.org/10.1016/S0963-8695(02)00047-6
  10. Pipia, L., X. Fabregas, A. Aguasca, and C. L. Martinez, 2008. Atmospheric artifact compensation in Ground-Based DInSAR application, IEEE Transactions on Geoscience and Remote Sensing, 5(1):88-92. https://doi.org/10.1109/LGRS.2007.908364
  11. Tarchi, D., N. Casagli, R. Fanti, D. D. Leva, G. Luzi, A. Pasuto, M. Pieraccini, and S. Silvano, 2003. Landslide monitoring by using Ground-Based SAR interferometry: anexample of application to the Tessina landslide in Italy, Engineering Geology, 68(1-2):15-30. https://doi.org/10.1016/S0013-7952(02)00196-5
  12. Zebker, H. A., P. A. Rosen, and S. Hensley, 1997. Atmospheric effects in interferometric synthetic aperture radar surface deformation and topographic maps, Journal of Geophysics Research, 102(B4):7547-7563 https://doi.org/10.1029/96JB03804