DOI QR코드

DOI QR Code

Development of Two-Finger Force Measuring System to Measure Two-Finger Gripping Force and Its Characteristic Evaluation

단축 힘센서를 이용한 두 손가락 잡기 힘측정장치 개발 및 특성평가

  • Kim, Hyeon-Min (ERI, Department of Control and Instrumentation Engineering, Gyeongsang National University) ;
  • Shin, Hi-Suk (Department of Rehabilitation Medicine, School of Medicine, Gyeongsang National University) ;
  • Yoon, Joung-Won (School of Mechanical Engineering, Gyeongsang National University) ;
  • Kim, Gab-Soon (ERI, Department of Control and Instrumentation Engineering, Gyeongsang National University)
  • 김현민 (경상대학교 제어계측공학과) ;
  • 신희석 (경상대학교 의학전문대학원 재활의학교실) ;
  • 윤정원 (경상대학교 기계공학부) ;
  • 김갑순 (경상대학교 제어계측공학과)
  • Received : 2011.03.08
  • Accepted : 2011.03.19
  • Published : 2011.05.31

Abstract

Finger patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers(thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). At present, most hospitals have used a thin plastic-plate for measuring the two-finger grasping force, and we can only judge that they can grasp the plate with their two-finger through it, because the plate can't measure the two-finger grasping force. But, recently, the force measuring system for measuring two-finger grasping force was developed using three-axis force sensor, but it is very expensive, because it has a three-axis force sensor. In this paper, two-finger force measuring system with a one-axis force sensor which can measure two-finger grasping force was developed. The one-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP(Digital Signal Processing). Also, the grasping force test of men was performed using the developed two-finger force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods, and the system can be used for measuring two-finger grasping force.

Keywords

References

  1. H.M. Kim, J.W. Yoon, H.S. Shin, and G.S. Kim, "Development of finger-force measuring system using three-axis force sensor for measuring two-finger force", ICROS, vol. 16, no. 9, pp.876-882, 2010.
  2. S. Olandersson, H. Lundqvistk , M. Bengtssonk , M. Lundahl, A. J. Baerveldt, and M. Hilliges, "Finger-force measurement-device for rehabilitation", Proc. of the 2005 IEEE 9th International Conference on Rehabilitation Robotics, Chicago, IL, USA, June 2005. https://doi.org/10.1109/ICORR.2005.1501069
  3. S. Li, F. Danion, M. L. Latash, J. M. Li, and V. M. Zatsiorsky," Bilateral deficit and symmetry in finger force production during two-hand multifinger tasks", Exp Brain Res, vol. 141, pp. 530 - 540, 2001. https://doi.org/10.1007/s002210100893
  4. ATI Industrial Automation, Multi-Axis Forcre/Torque Sensor, ATI Industrial Automation, pp.4-45, 2010.
  5. G. S. Kim and J. W. Yoon, "Development of calibration system for multi-axis force/moment sensor and its uncertainty evaluation", KSPE, vol. 24, no. 10, pp. 91-98, 2007.

Cited by

  1. Development of Force Sensors for Rectangular-Type Finger-Rehabilitation Robot Instruments and Their Characteristic Test vol.21, pp.2, 2012, https://doi.org/10.5369/JSST.2012.21.2.127