DOI QR코드

DOI QR Code

Clinical Efficacy of Radiation-Sterilized Allografts for Sellar Reconstruction after Transsphenoidal Surgery

  • Kim, Se-Jin (Department of Neurosurgery, Gyeongsang National University School of Medicine) ;
  • Jeon, Chi-Man (Department of Neurosurgery, Pusan National University School of Medicine) ;
  • Kong, Doo-Sik (Department of Neurosurgery, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Kwan (Department of Neurosurgery, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Jong-Hyun (Department of Neurosurgery, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Received : 2011.01.20
  • Accepted : 2011.12.19
  • Published : 2011.12.28

Abstract

Objective : The aim of this study was to assess the safety and efficacy of radiation-sterilized allografts of iliac bone and fascia lata from cadaver specimens to repair skull base defects after transsphenoidal surgery. Methods : Between May 2009 and January 2010, 31 consecutive patients underwent endonasal transsphenoidal surgery and all patients received sellar reconstruction using allografts following tumor removal. The allografts were obtained from the local tissue bank and harvested from cadaver donors. The specimens used in our approach were tensor fascia lata and the flat area of iliac bone. For preparation, allografts were treated with gamma irradiation after routine screening by culture, and then stored at $-70^{\circ}C$. Results : The mean follow-up period after surgery was 12.6 months (range, 7.4-16 months). Overall, postoperative cerebrospinal fluid (CSF) leaks occurred in three patients (9.7%) and postoperative meningitis in one patient (3.2%). There was no definitive evidence of wound infection at the routine postoperative follow-up examination or during re-do surgery in three patients. Postoperative meningitis in one patient was improved with the use of antibiotics and prolonged CSF diversion. Conclusion : We suggest that allograft materials can be a feasible alternative to autologous tissue grafts for sellar reconstruction following transsphenoidal surgery under selected circumstances such as no or little intraoperative CSF leaks.

Keywords

References

  1. Balsly CR, Cotter AT, Williams LA, Gaskins BD, Moore MA, Wolfinbarger L Jr : Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts. Cell Tissue Bank 9 : 289-298, 2008 https://doi.org/10.1007/s10561-008-9069-0
  2. Cavallo LM, Messina A, Esposito F, de Divitiis O, Dal Fabbro M, de Divitiis E, et al. : Skull base reconstruction in the extended endoscopic transsphenoidal approach for suprasellar lesions. J Neurosurg 107 : 713-720, 2007 https://doi.org/10.3171/JNS-07/10/0713
  3. Ciric I, Ragin A, Baumgartner C, Pierce D : Complications of transsphenoidal surgery : results of a national survey, review of the literature, and personal experience. Neurosurgery 40 : 225-236; discussion 236-237, 1997 https://doi.org/10.1097/00006123-199702000-00001
  4. de Divitiis E, Cavallo LM, Cappabianca P, Esposito F : Extended endoscopic endonasal transsphenoidal approach for the removal of suprasellar tumors : Part 2. Neurosurgery 60 : 46-58; discussion 58-59, 2007
  5. Dusick JR, Mattozo CA, Esposito F, Kelly DF : BioGlue for prevention of postoperative cerebrospinal fluid leaks in transsphenoidal surgery : a case series. Surg Neurol 66 : 371-376; discussion 376, 2006 https://doi.org/10.1016/j.surneu.2006.06.043
  6. Fideler BM, Vangsness CT Jr, Lu B, Orlando C, Moore T : Gamma irradiation : effects on biomechanical properties of human bone-patellar tendon-bone allografts. Am J Sports Med 23 : 643-646, 1995 https://doi.org/10.1177/036354659502300521
  7. Flynn MK, Webster GD, Amundsen CL : Abdominal sacral colpopexy with allograft fascia lata : one-year outcomes. Am J Obstet Gynecol 192 : 1496-1500, 2005 https://doi.org/10.1016/j.ajog.2004.11.025
  8. Grieb TA, Forng RY, Bogdansky S, Ronholdt C, Parks B, Drohan WN, et al. : High-dose gamma irradiation for soft tissue allografts : high margin of safety with biomechanical integrity. J Orthop Res 24 : 1011-1018, 2006 https://doi.org/10.1002/jor.20079
  9. Kelly DF, Oskouian RJ, Fineman I : Collagen sponge repair of small cerebrospinal fluid leaks obviates tissue grafts and cerebrospinal fluid diversion after pituitary surgery. Neurosurgery 49 : 885-889; discussion 889-890, 2001
  10. Leng LZ, Brown S, Anand VK, Schwartz TH : "Gasket-seal" watertight closure in minimal-access endoscopic cranial base surgery. Neurosurgery 62 : ONSE342-ONSE343; discussion ONSE343, 2008
  11. Nishioka H, Izawa H, Ikeda Y, Namatame H, Fukami S, Haraoka J : Dural suturing for repair of cerebrospinal fluid leak in transnasal transsphenoidal surgery. Acta Neurochir (Wien) 151 : 1427-1430, 2009 https://doi.org/10.1007/s00701-009-0406-2
  12. Rabadan AT, Hernandez D, Ruggeri CS : Pituitary tumors : our experience in the prevention of postoperative cerebrospinal fluid leaks after transsphenoidal surgery. J Neurooncol 93 : 127-131, 2009 https://doi.org/10.1007/s11060-009-9858-8
  13. Seda L, Camara RB, Cukiert A, Burattini JA, Mariani PP : Sellar floor reconstruction after transsphenoidal surgery using fibrin glue without grafting or implants : technical note. Surg Neurol 66 : 46-49; discussion 49, 2006 https://doi.org/10.1016/j.surneu.2005.10.021
  14. Shiley SG, Limonadi F, Delashaw JB, Barnwell SL, Andersen PE, Hwang PH, et al. : Incidence, etiology, and management of cerebrospinal fluid leaks following trans-sphenoidal surgery. Laryngoscope 113 : 1283-1288, 2003 https://doi.org/10.1097/00005537-200308000-00003
  15. Snyderman CH, Pant H, Carrau RL, Prevedello D, Gardner P, Kassam AB : What are the limits of endoscopic sinus surgery? : the expanded endonasal approach to the skull base. Keio J Med 58 : 152-160, 2009 https://doi.org/10.2302/kjm.58.152
  16. Vastel L, Lemoine CT, Kerboull M, Courpied JP : Structural allograft and cemented long-stem prosthesis for complex revision hip arthroplasty : use of a trochanteric claw plate improves final hip function. Int Orthop 31 : 851-857, 2007 https://doi.org/10.1007/s00264-006-0275-8

Cited by

  1. Comparative study and histomorphometric analysis of bone allografts lyophilized and sterilized by autoclaving, gamma irradiation and ethylene oxide in rats vol.28, pp.1, 2011, https://doi.org/10.1590/s0102-86502013000100011
  2. Disinfection of human musculoskeletal allografts in tissue banking: a systematic review vol.17, pp.4, 2011, https://doi.org/10.1007/s10561-016-9584-3
  3. Heterogeneity in Outcome Reporting in Endoscopic Endonasal Skull Base Reconstruction: A Systematic Review vol.82, pp.5, 2011, https://doi.org/10.1055/s-0040-1714108