A Study on Development of a Circulating Pump with Space Constraintst

설치공간이 제한된 순환펌프의 개발에 관한 연구

  • 윤의수 (한국기계연구원 에너지기계연구실) ;
  • 유일수 (한국기계연구원 에너지기계연구실) ;
  • 황순찬 (한국기계연구원 에너지기계연구실) ;
  • 오형우 (충주대학교 기계공학과)
  • Received : 2010.09.27
  • Accepted : 2010.12.23
  • Published : 2011.02.01

Abstract

A circulating pump with installation space constraints was developed satisfying performance requirements such as flowrate, head and NPSHAv. The development procedures are composed of conceptual design, configuration design, performance analysis by CFD and performance test which were established in KIMM. The developed pump is OH4 type centrifugal pump which has a mixed-flow type impeller, a double volute and a rigid coupling. As a result of tests, the pump proved to meet all the requirements including space constraints and performance.

Keywords

References

  1. ANSI/HI 1.3-2009, Rotodynamic pumps for design and application, pp. 11.
  2. O. E. Balje, 1981, Turbomachines, John Wiley & Sons,pp. 55, 58.
  3. T. Wright, 1999, Fluid machinery, CRC Press, pp. 61.
  4. G. F. Wislicenus, R. M. Watson and I. J. Karassik,1939, “Cavitation characteristics of centrifugal pumps,”Tans ASME, Vol. 61, pp. 17.
  5. ANSI/HI 1.3 - 2000, Centrifugal pumps for design andapplication, pp. 32.
  6. J. F. Gülich, 2010, Centrifugal pump, 2nd Ed., Springer,pp. 271.
  7. 오형우, 정명균, 1997, “단(양) 흡입형 원심 펌프의 성능 예측,” 한국자동차학회논문집, 5권, 6호, pp. 103-106.
  8. 오형우, 윤의수, 정명균, 1998, “혼류 펌프의 성능해석,” 대한기계학회 논문집(B), 제22권 제1호, 1998, pp. 70-78.
  9. A. J. Stepanoff, 1993, Centrifugal and axial flow Pumps,Krieger Pub. Co.
  10. K. Imaichi, Y. Murakami, H. Tsurusaki, 2002, 趙江來, 펌프설계의 기초, 大英社.
  11. H. W. Oh, and E. S. Yoon, 2008, “Hydrodynamicallydetailed performance analysis of a mixed-flow waterjetpump using computational fluid dynamics,” IMechE 222Pt. C, J. of Engineering Science, pp. 1861-1867.
  12. ANSI/HI 1.6-2000, Centrifugal pump tests.