DOI QR코드

DOI QR Code

Reliability of the Radiologic Measurement Methods for Assessment of Osteoporosis Using the Digital Hip Radiograph

고관절 디지털 방사선을 이용하여 측정한 방사선적 골다공증 측정 방법들의 유용성

  • Yun, Ho-Hyun (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Yi, Ju-Won (Department of Orthopedic Surgery, College of Medicine, Ewha Womans University) ;
  • Lim, Deuk-Soo (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Park, Sung-Chul (Department of Orthopedic Surgery, Seoul Veterans Hospital) ;
  • Oh, Seong-Rok (Department of Orthopedic Surgery, Seoul Veterans Hospital)
  • 윤호현 (서울보훈병원 정형외과) ;
  • 이주원 (이화여자대학교 의과대학 정형외과학교실) ;
  • 임득수 (서울보훈병원 정형외과) ;
  • 박성철 (서울보훈병원 정형외과) ;
  • 오성록 (서울보훈병원 정형외과)
  • Published : 2011.06.30

Abstract

Purpose: We evaluated the usefulness of radiographic parameters for osteoporosis by analyzing the results of radiographic parameters determined by digital hip radiographs and bone mineral density T-scores, as assessed by Dual Energy X-ray Absorptiometry (DEXA). Materials and Methods: The authors reviewed 100 subjects in the hip fracture group and 50 in the non-fracture control group. Digital hip radiographs were assessed to determine the values of Singh index, Canal-to-Calcar Ratio, and Cortical Thickness Index (CTI). Bone mineral density was assessed by DEXA. Results: Intraclass Correlation Coefficient (ICC) results of the CTI were above 0.8 in the fracture group. Compared to the control group, the fracture group showed higher ICCs. Interobserver ICCs were especially lower in the control group. There were statistically significant correlations between CTI and DEXA (r=0.50~0.58, p<0.05). In the analysis of ROC curves, a mean threshold for CTI set a value of 0.54 (0.53~0.55), and mean sensitivity and specificity were 75.5% (69~79%) and 67.8% (65~78%), respectively. Conclusion: CTI showed reasonable reliability and correlation with DEXA results. CTI was a useful radiographic parameter to alert the surgeon to recommend referral for osteoporosis evaluation in elderly hip fracture patients.

목적: 디지털 방사선 영상을 이용하여 방사선적 골다공증 지표들을 측정하고 방사선적 골다공증 지표들의 유용성을 알아보고자 하였다. 대상 및 방법: 고관절 주위골절로 진단 받았던 65세 이상의 환자 100 명을 골절 군으로 설정하고 65세 미만의 비 골절 50명을 대조 군으로 설정하였다. Singh Index, Canal-to-Calcar Ratio, Cortical Thickness Index (CTI)를 측정하였으며 골밀도 측정을 위해서 이중 에너지 방사선 (DEXA) 골밀도 검사를 시행하였다. 결과: CTI 측정 결과들에 대한 관찰자 내 및 관찰자간 Intraclass Correlation Coefficient (ICC) 결과상 골절 군에서는 ICC 값이 모두 0.8 이상으로 대조 군과 비교 시 골절 군에서 모두 높았으며 대조 군에서는 특히 관찰자간 ICC 값이 상대적으로 낮았다. CTI와 DEXA 골밀도 검사결과들간에는 통계적으로 유의한 상관관계가 관찰되었다(r=0.50~0.58, p<0.05). 결론: CTI가 만족스러운 신뢰도를 보이며 DEXA 골밀도 검사와의 연관성을 보여서 특히 노령의 고관절 주위 골절 환자들에서 골다공증을 진단하고 치료하기 위한 노력을 유도하는데 유용하다고 판단된다.

Keywords

References

  1. Aloia JF, Vaswani A, Atkins H, Zanzi I, Ellis K, Cohn SH. Radiographic morphometry and osteopenia in spinal osteoporosis. J Nucl Med. 1977;18:425-31.
  2. Devlin H, Karayianni K, Mitsea A, et al. Diagnosing osteoporosis by using dental panoramic radiographs: the OSTEODENT project. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;104:821-8. https://doi.org/10.1016/j.tripleo.2006.12.027
  3. Singh M, Nagrath AR, Maini PS. Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis. J Bone Joint Surg Am. 1970;52:457-67.
  4. Sah AP, Thornhill TS, Leboff MS, Glowacki J. Correlation of plain radiographic indices of the hip with quantitative bone mineral density. Osteoporos Int. 2007;18:1119-26. https://doi.org/10.1007/s00198-007-0348-6
  5. Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231-42. https://doi.org/10.1016/8756-3282(93)90146-2
  6. Boehm HF, Link TM. Bone imaging: traditional techniques and their interpretation. Curr Osteoporos Rep. 2004;2:41-6. https://doi.org/10.1007/s11914-004-0002-6
  7. O'Gradaigh D, Debiram I, Love S, Richards HK, Compston JE. A prospective study of discordance in diagnosis of osteoporosis using spine and proximal femur bone densitometry. Osteoporos Int. 2003;14:13-8. https://doi.org/10.1007/s00198-002-1311-1
  8. Astrand J, Thorngren KG, Tägil M, Akesson K. 3-year follow-up of 215 fracture patients from a prospective and consecutive osteoporosis screening program. Fracture patients care! Acta Orthop. 2008;79:404-9. https://doi.org/10.1080/17453670710015328
  9. Bergmann P, Body JJ, Boonen S, et al. Evidence-based guidelines for the use of biochemical markers of bone turnover in the selection and monitoring of bisphosphonate treatment in osteoporosis: a consensus document of the Belgian Bone Club. Int J Clin Pract. 2009;63:19-26.
  10. Civitelli R, Armamento-Villareal R, Napoli N. Bone turnover markers: understanding their value in clinical trials and clinical practice. Osteoporos Int. 2009;20:843-51. https://doi.org/10.1007/s00198-009-0838-9
  11. Szulc P, Delmas PD. Biochemical markers of bone turnover: potential use in the investigation and management of postmenopausal osteoporosis. Osteoporos Int. 2008;19:1683-704. https://doi.org/10.1007/s00198-008-0660-9
  12. Kawashima T, Uhthoff HK. Pattern of bone loss of the proximal femur: a radiologic, densitometric, and histomorphometric study. J Orthop Res. 1991;9:634-40. https://doi.org/10.1002/jor.1100090503
  13. Koot VC, Kesselaer SM, Clevers GJ, de Hooge P, Weits T, van der Werken C. Evaluation of the Singh index for measuring osteoporosis. J Bone Joint Surg Br. 1996;78:831-4.
  14. Pogrund H, Rigal WM, Makin M, Robin G, Menczel J, Steinberg R. Determination of osteoporosis in patients with fractured femoral neck using the Singh index: a Jerusalem study. Clin Orthop Relat Res. 1981;156:189-95.
  15. Lewiecki EM, Baim S, Langman CB, Bilezikian JP. The official positions of the International Society for Clinical Densitometry: perceptions and commentary. J Clin Densitom. 2009;12:267-71. https://doi.org/10.1016/j.jocd.2009.03.098
  16. Watts NB. Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA). Osteoporos Int. 2004;15:847-54. https://doi.org/10.1007/s00198-004-1681-7
  17. Masud T, Jawed S, Doyle DV, Spector TD. A population study of the screening potential of assessment of trabecular pattern of the femoral neck (Singh index): the Chingford Study. Br J Radiol. 1995;68:389-93. https://doi.org/10.1259/0007-1285-68-808-389
  18. Miller RG. Osteoporosis in postmenopausal women. Therapy options across a wide range of risk for fracture. Geriatrics. 2006;61:24-30.
  19. Hauschild O, Ghanem N, Oberst M, et al. Evaluation of Singh index for assessment of osteoporosis using digital radiography. Eur J Radiol. 2009;71:152-8. https://doi.org/10.1016/j.ejrad.2008.03.019
  20. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-74. https://doi.org/10.2307/2529310
  21. Wagner S, Stäbler A, Sittek H, et al. Diagnosis of osteoporosis: visual assessment on conventional versus digital radiographs. Osteoporos Int. 2005;16:1815-22. https://doi.org/10.1007/s00198-005-1937-x
  22. Lindhardt FE. Clinical experiences with computed radiography. Eur J Radiol. 1996;22:175-85. https://doi.org/10.1016/0720-048X(96)89640-9
  23. Okamura T, Tanaka S, Koyama K, et al. Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen. Eur Radiol. 2002;12:1741-7. https://doi.org/10.1007/s00330-001-1283-0

Cited by

  1. 근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도 vol.12, pp.6, 2012, https://doi.org/10.5392/jkca.2012.12.06.353
  2. Comparative Study of Osteoporosis Treatment of Elderly Patients with Degenerative Osteoarthritis of the Knee Joints, according to the Korean Health Insurance Review & Assessment Service Criteria v vol.47, pp.5, 2012, https://doi.org/10.4055/jkoa.2012.47.5.368
  3. Which AO/OTA 31-A2 pertrochanteric fractures can be treated with a dynamic hip screw without developing a lateral wall fracture? A CT-based study vol.40, pp.5, 2011, https://doi.org/10.1007/s00264-015-2835-2
  4. Correlation between plain X‐ray measurements and DXA scans, and its possible use as a screening tool for performing DXA scans vol.75, pp.11, 2011, https://doi.org/10.1111/ijcp.14784