DOI QR코드

DOI QR Code

Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block

  • 윤민정 (연세대학교 치과대학병원 보존과) ;
  • 송민주 (연세대학교 치과대학 강남세브란스병원 보존과) ;
  • 신수정 (연세대학교 치과대학 강남세브란스병원 보존과) ;
  • 김의성 (연세대학교 치과대학병원 보존과)
  • Yoon, Min-Jung (Department of Conservative Dentistry, Yonsei University College of Dentistry) ;
  • Song, Min-Ju (Department of Conservative Dentistry, Gangnam Severance Hospital, Yonsei University College of Dentistry) ;
  • Shin, Su-Jung (Department of Conservative Dentistry, Gangnam Severance Hospital, Yonsei University College of Dentistry) ;
  • Kim, Eui-Seong (Department of Conservative Dentistry, Yonsei University College of Dentistry)
  • 투고 : 2010.11.24
  • 심사 : 2011.01.07
  • 발행 : 2011.01.31

초록

연구목적: 본 연구의 목적은 서로 다른 기하학적 형태를 가진 3가지 Ni-Ti 파일, 즉 K3, NRT, Profle을 사용하여 레진 블록으로 제작된 만곡 근관에서의 apical transportation 양상 및 working length 변화를 서로 비교하는 것이다. 연구 재료 및 방법: 실험 방법은 30개의 레진 블록을 Schneider technque을 사용하여 만곡도 측정 후 각 group당 임의로 10개씩 배분하였다. 이를 각 Ni-Ti 파일을 사용하여 crown down technique으로 근관 성형하였다. 이의 분석을 위해 double radiograph superimposition method (Backman CA 1992)를 사용하고, 분석의 정확성과 일관성을 위해 특별히 고안된 jig, digital X-ray 및 apical transportation의 측정 시 CAD/CAM software를 이용하였다. Apical transportation 양은 '근단공-0.5 mm'부위로부터 0, 1, 3, 5 mm에서 측정 하였으며, working length 변화는 근관 성형 전후의 working length 변화를 측정하였다. 또 통계 처리는 각 group의 apical transportation 양과 working length 변화를 Kruskal-Wallis One Way Analysis로 분석 후 다중 비교는 Mann-Whitney U-test를 사용하였다. 결과: 각 group간 working lengh 변화 및 0, 1, 3 mm 부위에서의 apical transportation 측정 값 사이에는 유의할만한 차이가 관찰되지 않았으나(p = 0.924), 5 mm 부위에서는 K3와 Profile사이에 유의할 만한 차이가 있었다(p = 0.027). 결론: 서로 다른 기하학적인 형태를 가진 3가지 Ni-Ti 파일의 apical transportation 및 working length 변화 정도 평가시, 본 연구의 범위 내에서는 3가지 파일 모두 유의할 만한 차이를 보이지 않은 가운데 본래의 근관 형태를 잘 유지한다고 할 수 있다.

Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.

키워드

참고문헌

  1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18(2):269-296.
  2. al-Omari MA, Dummer PM, Newcombe RG, Doller R. Comparison of six files to prepare simulated root canals. 2. Int Endod J 1992;25(2):67-81. https://doi.org/10.1111/j.1365-2591.1992.tb00739.x
  3. Schafer E, Tepel J, Hoppe W. Properties of endodontic hand instruments used in rotary motion. Part 2. Instrumentation of curved canals. J Endod 1995;21(10):493-497. https://doi.org/10.1016/S0099-2399(06)80519-4
  4. Roane JB, Sabala CL, Duncanson MG, Jr. The “balanced force”concept for instrumentation of curved canals. J Endod 1985;11(5):203-211. https://doi.org/10.1016/S0099-2399(85)80061-3
  5. Abou-Rass M, Frank AL, Glick DH. The anticurvature filing method to prepare the curved root canal. J Am Dent Assoc 1980;101(5):792-794. https://doi.org/10.14219/jada.archive.1980.0427
  6. Caldwell JL. Change in working length following instrumentation of molar canals. Oral Surg Oral Med Oral Pathol 1976;41(1):114-118. https://doi.org/10.1016/0030-4220(76)90260-7
  7. Civjan S, Huget EF, DeSimon LB. Potential applications of certain nickel-titanium (nitinol) alloys. J Dent Res 1975;54(1):89-96. https://doi.org/10.1177/00220345750540014301
  8. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14(7):346-351. https://doi.org/10.1016/S0099-2399(88)80196-1
  9. Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996;22(7):369-375. https://doi.org/10.1016/S0099-2399(96)80221-4
  10. Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995;21(3):146-151. https://doi.org/10.1016/S0099-2399(06)80441-3
  11. Elliott LM, Curtis RV, Pitt Ford TR. Cutting pattern of nickel-titanium files using two preparation techniques. Endod Dent Traumatol 1998;14(1):10-15. https://doi.org/10.1111/j.1600-9657.1998.tb00802.x
  12. Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry. Am J Dent 2001;14(5):324-333.
  13. Bryant ST, Thompson SA, al-Omari MA, Dummer PM. Shaping ability of Profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 1. Int Endod J 1998;31(4):275-281. https://doi.org/10.1046/j.1365-2591.1998.00153.x
  14. Bramante CM, Berbert A, Borges RP. A methodology for evaluation of root canal instrumentation. J Endod 1987;13(5):243-245. https://doi.org/10.1016/S0099-2399(87)80099-7
  15. Garip Y, Gunday M. The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals. Int Endod J 2001;34(6):452-457. https://doi.org/10.1046/j.1365-2591.2001.00416.x
  16. Backman CA, Oswald RJ, Pitts DL. A radiographic comparison of two root canal instrumentation techniques. J Endod 1992;18(1):19-24. https://doi.org/10.1016/S0099-2399(06)81137-4
  17. Glickman GN, Koch KA. 21st-century endodontics. J Am Dent Assoc 2000;131 Suppl:39S-46S. https://doi.org/10.14219/jada.archive.2000.0401
  18. Pruett JP, Clement DJ, Carnes DL, Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997;23(2):77-85. https://doi.org/10.1016/S0099-2399(97)80250-6
  19. Bonetti Filho I, Miranda Esberard R, de Toledo Leonardo R, del Rio CE. Microscopic evaluation of three endodontic files pre- and postinstrumentation. J Endod 1998;24(7):461-464. https://doi.org/10.1016/S0099-2399(98)80046-0
  20. Weine FS, Kelly RF, Lio PJ. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod 1975;1(8):255-262. https://doi.org/10.1016/S0099-2399(75)80037-9
  21. Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. Int Endod J 1985;18(4):240-246. https://doi.org/10.1111/j.1365-2591.1985.tb00450.x
  22. Dummer PM, Alodeh MH, al-Omari MA. A method for the construction of simulated root canals in clear resin blocks. Int Endod J 1991;24(2):63-66. https://doi.org/10.1111/j.1365-2591.1991.tb00809.x
  23. Cha YB, Jung IY, Lee SJ, et al. Shaping ability of three ProFile rotary instrumentation techniques in simulated resin root canals. J Endod 2000;26(12):719-723. https://doi.org/10.1097/00004770-200012000-00013
  24. Thompson SA, Dummer PM. Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 1. Int Endod J 1997;30(1):1-7. https://doi.org/10.1111/j.1365-2591.1997.tb01093.x
  25. Schafer E, Florek H. Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals. Int Endod J 2003;36(3):199-207. https://doi.org/10.1046/j.1365-2591.2003.00643.x
  26. Iqbal MK, Maggiore F, Suh B, Edwards KR, Kang J, Kim S. Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques. J Endod 2003;29(9):587-591. https://doi.org/10.1097/00004770-200309000-00011

피인용 문헌

  1. A comparison of dimensional standard of several nickel-titanium rotary files vol.39, pp.1, 2014, https://doi.org/10.5395/rde.2014.39.1.7