References
- M. H. Asif, S. M. Usman Ali, O. Nur, M. Willander, C. Brnnmark, P. Strlfors, U. H. Englund, F. Elinder and B. Danielsson, Biosens. bioelectron, 25, 2205 (2010). https://doi.org/10.1016/j.bios.2010.02.025
- N. A. Rakow and K. S. Suslick, Nature, 406, 710 (2000). https://doi.org/10.1038/35021028
- R. W. Keay and C. J. McNeil, Biosens. Bioelectron. 13, 963 (1998). https://doi.org/10.1016/S0956-5663(98)00008-6
- L. C. Clark and C. Lyons, Annals of the New York Academy of Sciences, 102, 29 (1962).
- K. Narasimham and L.B. Wingard, Anal. Chem, 58, 2984 (1986). https://doi.org/10.1021/ac00127a019
- Y. Degani and A. Heller, J. Am. Chem. Soc, 110, 2615 (1988). https://doi.org/10.1021/ja00216a040
- G. Firtier, M. Vaillancourt and D. Belanger, Electroanalysis, 4, 275 (1992). https://doi.org/10.1002/elan.1140040304
- F. Mizutani, S. Yabuki and T. Katsura, Anal. Chim. Acta, 274, 201 (1993). https://doi.org/10.1016/0003-2670(93)80466-X
- G. F. Khan, E. Kobatake, Y. Ikariyama and M. Aizawa, Anal. Chim. Acta, 281, 527 (1993). https://doi.org/10.1016/0003-2670(93)85011-8
- M. Shaolin, J. Electroanal. Chem, 370, 135 (1994). https://doi.org/10.1016/0022-0728(93)03166-M
- Z. Zhang, W. Bao and C. Liu, Talanta, 41, 875 (1994). https://doi.org/10.1016/0039-9140(94)E0050-2
- J. Q. Kan, F. Zhou, S. L. Mu AND Y. J. Shi, Sens. Actuators B, 30, 7 (1996). https://doi.org/10.1016/0925-4005(95)01733-C
- M. Castillo-Ortega, D. Rodriguez, J. Encinas, M. Plascencia, F. A. Mendez-Velarde and R. Olayo, Sensors and Actuators B, 85, 19 (2002). https://doi.org/10.1016/S0925-4005(02)00045-X
- Z. J. Liu, B. H. Liu, J. L. Kong and J. Q. Deng, Anal. Chem., 72, 4707 (2000). https://doi.org/10.1021/ac990490h
- B. Q. Wang, B. Li, Z. X. Wang, G. B. Xu, Q. Wang and S. J. Dong, Anal. Chem., 71, 1935 (1999). https://doi.org/10.1021/ac980940q
- M. Mascini, M. Iannello and G. Palleschi, Anal. Chim. Acta, 146, 135 (1983). https://doi.org/10.1016/S0003-2670(00)80600-5
- L. T. Jin, J. S. Ye, W. Tong and Y. Z. Fang, Mikrochim. Acta, 112, 71 (1993). https://doi.org/10.1007/BF01243323
- J. Park, H. Kim and Y. Son, Sens. Actuators B, 133, 244 (2008). https://doi.org/10.1016/j.snb.2008.02.029
- M. Lee, Y. Son, J. Park and Y. Lee, Mole. Cryst. Liq. Cryst., 492, 155/[519] (2008).
- Y. -Q and K. -K. Shiu, Electroanalysis, 16, 1806 (2004). https://doi.org/10.1002/elan.200303037
- M. H. Xue, Q. Xu, M. Zhou and J. J. Zhu, Electrochem, Commun., 8, 1468 (2006). https://doi.org/10.1016/j.elecom.2006.07.019
- T. Chung, S. Park and H. Kim, Phys. & High Tech. 24, Oct (2004).
- C. Chen, K. Ishihara, N. Nakabayashi, E. Tamiya and I. Karube, J. Biomed. Microdevices 1:2, 155 (1999).
- S. Zhang, N. Wang, H. Yu, Y. Niu and C. Sun, Bioelectrochemistry, 67, 15 (2005). https://doi.org/10.1016/j.bioelechem.2004.12.002
- W. Yang, J. Wang, S. Zhao, Y. Sun and C. Sun, Electrochem, Commun., 8, 665 (2006). https://doi.org/10.1016/j.elecom.2005.11.014
- Y. Sun, Y. Bai, W. Yang and C. Sun, Electrochim. Acta, 52, 7352 (2007). https://doi.org/10.1016/j.electacta.2007.06.007
Cited by
- On-chip highly sensitive saliva glucose sensing using multilayer films composed of single-walled carbon nanotubes, gold nanoparticles, and glucose oxidase vol.4, 2015, https://doi.org/10.1016/j.sbsr.2015.04.006
- Processable enzyme-hybrid conductive polymer composites for electrochemical biosensing vol.100, 2018, https://doi.org/10.1016/j.bios.2017.09.021
- Activity determination of FAD-dependent glucose dehydrogenase immobilized in PEDOT: PSS-PVA composite films for biosensor applications vol.16, pp.6, 2016, https://doi.org/10.1002/elsc.201600128
- Electrooxidation of Zolpidem and its Voltammetric Quantification in Standard and Pharmaceutical Formulation using Pencil Graphite Electrode vol.7, pp.1, 2016, https://doi.org/10.5229/JECST.2016.7.1.68