초록

This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

키워드

참고문헌

  1. T. Takagi, Y. Yamakoshi, J. Baba, K. Uemura and T. Sakaguchi, "A new algorithm of an accurate fault location for EHV/UHV transmission lines. Part I: Fourier transform method", IEEE Trans. Power Appar. Syst. PAS-100, 3, (1981), pp. 1316-1322. https://doi.org/10.1109/TPAS.1981.316604
  2. T. Takagi, Y. Yamakoshi, J. Baba, K. Uemura and T. Sakaguchi, "A new algorithm of an accurate fault location for EHV/UHV transmission lines. Part II: Laplace transform method", IEEE Trans. Power Appar. Syst. 101, 3, (1982), pp. 564-573. https://doi.org/10.1109/TPAS.1982.317269
  3. S. A. Soliman, M. H. Abdel-Rahman, E. Al-Attar and M. E. El-Hawary, "An algorithm for estimating fault location in an unbalanced three-phase power system", International Journal of Electrical Power and Energy Systems, Vol. 24, 7, Oct. 2002, pp 515-520. https://doi.org/10.1016/S0142-0615(01)00051-5
  4. B. Liana, M. M. A. Salamaa and A. Y. Chikhanib, "A time domain differential equation approach using distributed parameter line model for transmission line fault location algorithm", Electric Power Systems Research, Vol. 46, Issue 1, July 1998, pp 1-10. https://doi.org/10.1016/S0378-7796(97)01231-5
  5. A. Gopalakrishnan, M. Kezunovic, S.M.McKenna, D.M. Hamai, "Fault location using the distributed parameter transmission line model", IEEE Transactions on Power Delivery, Vol. 15, Issue 4, Oct. 2000 pp-1169-1174. https://doi.org/10.1109/61.891498
  6. M. Kizilcay, P. La Seta, D. Menniti, M. Igel, "A new fault location approach for overhead HV lines with line equations", IEEE Power Tech Conference Proceedings 2003, Bologna, 23-26 June 2003, Vol. 3, pages: 7 https://doi.org/10.1109/PTC.2003.1304373
  7. G. B. Ancell, N. C. Pahalawaththa, "Maximum likelihood estimation of fault location on transmission lines using traveling waves," IEEE Trans. Power Delivery, Vol.9, pp.680-689, Apr. 1994. https://doi.org/10.1109/61.296245
  8. M.M. Tawfik, M.M. Morcos, "A novel approach for fault location on transmission lines", IEEE Power Eng. Rev. 18, Nov. 1998, pp. 58U˝ 60. https://doi.org/10.1109/39.726909
  9. H. Heng-xu, Z. Bao-hui, L. Zhi-lai, "A novel principle of single-ended fault location technique for EHV transmission lines", IEEE Transactions on Power Delivery, Vol. 18, 4, Oct. 2003, pp. 1147-1151. https://doi.org/10.1109/TPWRD.2003.817505
  10. Liqun Shang, Wei Shi, "Fault Location Algorithm for Double-Circuit Transmission Lines Based on Distributed Parameter Model", Journal of Xi'An Jiaotong University, Vol. 39, No. 12, Dec. 2005
  11. Guobing Song, Suonan Jiale, Qingqiang Xu, Ping Chen; Yaozhong Ge, "Parallel transmission lines fault location algorithm based on differential component net", IEEE Transactions on Power Delivery, Vol. 20, Issue 4, pp.2396-2406, Oct. 2005. https://doi.org/10.1109/TPWRD.2005.852364
  12. Kawady T., Stenzel J., "A practical fault location approach for double circuit transmission lines using single end data", IEEE Transactions on Power Delivery, Vol.18, Issue 4, pp.1166-1173, Oct. 2003 https://doi.org/10.1109/TPWRD.2003.817503
  13. Hongchun Shu, Dajun Si, Yaozhong Ge, Xunyun Chen, "A least error squares method for locating fault on coupled double-circuit HV transmission line using one terminal data", Proceedings on PowerCon 2002, Vol.4, pp.2101-2105, Oct. 2002
  14. Yong-Jin Ahn, Myeon-Song Choi, Sang-Hee Kang, Seung-Jae Lee, "An accurate fault location algorithm for double-circuit transmission systems", IEEE Power Engineering Society Summer Meeting, Vol.3, pp.1344-1349, July 2000.
  15. Xia Yang, Myeon-Song Choi, and Seung-Jae Lee, "Double-Circuit Transmission Lines Fault location Algorithm for Single Line-to-Ground Fault". Journal of Electrical Engineering & Technology, Vol.2, No.4, pp.434-440, Dec. 2007. https://doi.org/10.5370/JEET.2007.2.4.434

피인용 문헌

  1. Four-Leg-Based Fault-Tolerant Matrix Converter Schemes Based on Switching Function and Space Vector Methods vol.59, pp.1, 2012, https://doi.org/10.1109/TIE.2011.2143378