DOI QR코드

DOI QR Code

Wound-State Monitoring for Burn Patients Using E-Nose/SPME System

  • Byun, Hyung-Gi (School of Electronics, Information & Communication Engineering, Kangwon National University) ;
  • Persaud, Krishna C. (School of Chemical Engineering and Analytical Science, The University of Manchester) ;
  • Pisanelli, Anna Maria (School of Chemical Engineering and Analytical Science, The University of Manchester)
  • 투고 : 2009.05.25
  • 심사 : 2010.02.03
  • 발행 : 2010.06.30

초록

Array-based gas sensors now offer the potential of a robust analytical approach to odor measurement for medical use. We are developing a fast reliable method for detection of microbial infection by monitoring the headspace from the infected wound. In this paper, we present initial results obtained from wound-state monitoring for burn patients using an electronic nose incorporating an automated solid-phase microextraction (SPME) desorption system to enable the system to be used for clinical validation. SPME preconcentration is used for sampling of the headspace air and the response of the sensor module to variable concentrations of volatiles emitted from SPME fiber is evaluated. Gas chromatography-mass spectrometry studies prove that living bacteria, the typical infectious agents in clinical practice, can be distinguished from each other by means of a limited set of key volatile products. Principal component analysis results give the first indication that infected patients may be distinguished from uninfected patients. Microbial laboratory analysis using clinical samples verifies the performance of the system.

키워드

참고문헌

  1. J.W. Gardner, H.W. Shin, and E.L. Hines, "An Electronic Nose System to Diagnose Illness," Sensors and Actuators B: Chemical, vol. 70, 2000, pp. 19-24. https://doi.org/10.1016/S0925-4005(00)00548-7
  2. J.W. Gardner et al., "Identification of Staphlococcus Aureus Infections in Hospital Environment: Electronic Nose Based Approach," Sensors and Actuators B: Chemical, vol. 109, 2005, pp. 355-362. https://doi.org/10.1016/j.snb.2005.01.013
  3. T.D. Gibson et al., "Detection and Simultaneous Identification of Micro Organisms from Headspace Samples Using an Electronic Nose," Sensors and Actuators B: Chemical vol. 44, 1997, pp. 413-422. https://doi.org/10.1016/S0925-4005(97)00235-9
  4. Keith F. Cutting, "Wound Healing, Bacteria and Topical Therapies," EWMA J., vol. 3, no. 1, 2003, pp. 17-19.
  5. P.G. Bowler, B.I. Duerden, and D.G. Armstrong, "Wound Microbiology and Associated Approaches to Wound Management," Clinical Microbiology Reviews, vol. 14, no. 2, 2001, pp. 244-269. https://doi.org/10.1128/CMR.14.2.244-269.2001
  6. H. Vindenes and R. Bjerknes, "Microbial Colonization of Large Wounds," Burns, vol. 21, no. 8, 1995, pp. 575-579. https://doi.org/10.1016/0305-4179(95)00047-F
  7. G. Revathi, J. Puri, and B.K. Jain, "Bacteriology of Burns," Burns, vol. 24, no. 4, 1998, pp. 347-349. https://doi.org/10.1016/S0305-4179(98)00009-6
  8. H.A.L. Mousa, "Aerobic, Anaerobic and Fungal Burn Wound Infections," J. Hospital Infection, vol. 37, 1997, pp. 317-323. https://doi.org/10.1016/S0195-6701(97)90148-1
  9. P.P. Gogia, "Physiology of Wound Healing" Clinical Wound Management, ed. P.P. Gogia, New Jersey, USA: Slack Inc., 1995.
  10. M.C. White, Katharine Thornton, Amber E.R. Young, "Early Diagnosis and Treatment of Toxic Shock Syndrome in Paediatric Burns," Burns, vol. 31, no. 2, 2005, pp. 193-197. https://doi.org/10.1016/j.burns.2004.09.017
  11. Z.M. Zhang et al., "The Study of Fingerprint Characteristics of the Emanations from Human Skin Using the Original Sampling System by SPME-GC/MS," J. Chromatography B, 822, 2005, pp. 244-252. https://doi.org/10.1016/j.jchromb.2005.06.026
  12. P. Obee et al., "An Evaluation of Eifferent Methods for Recovery of Meticillin-Resistant Staphylococcus Aureas from Environmental Surfaces." J. Hospital Infection, vol. 65, 2007, pp. 35-41. https://doi.org/10.1016/j.jhin.2006.09.010
  13. D.M.M. Queiroz, E.N. Mendes, and G.A. Rocha, "Indicator Medium for Isolation of Campylobacter Pylori," J. Clin. Microbiol., vol. 25, 1987, pp. 2378-2379.
  14. www.sisweb.com.
  15. www.figarosensor.com.
  16. A. Setkus et al., "Qualitative and Quantitative Characterization of Living Bacteria by Dynamic Response Parameters of Gas Sensor Array," Sensors and Actuators B: Chemical, vol. 130, 2008, pp. 351-358. https://doi.org/10.1016/j.snb.2007.09.048

피인용 문헌

  1. Fast response formaldehyde gas sensor for USN application vol.25, pp.None, 2011, https://doi.org/10.1016/j.proeng.2011.12.264
  2. An Identification Technique Based on Adaptive Radial Basis Function Network for an Electronic Odor Sensing System vol.20, pp.3, 2010, https://doi.org/10.5369/jsst.2011.20.3.151
  3. Fabrication of a HCHO gas sensor based on a MEMS heater and inkjet printing vol.60, pp.2, 2010, https://doi.org/10.3938/jkps.60.225
  4. Encapsulation of Semiconductor Gas Sensors with Gas Barrier Films for USN Application vol.34, pp.5, 2010, https://doi.org/10.4218/etrij.12.0112.0266
  5. Microbial volatile compounds in health and disease conditions vol.6, pp.2, 2010, https://doi.org/10.1088/1752-7155/6/2/024001
  6. Background Interference Elimination in Wound Infection Detection by Electronic Nose Based on Reference Vector-based Independent Component Analysis vol.11, pp.7, 2010, https://doi.org/10.3923/itj.2012.850.858
  7. A PSO-SVM Method for Parameters and Sensor Array Optimization in Wound Infection Detection based on Electronic Nose vol.7, pp.11, 2010, https://doi.org/10.4304/jcp.7.11.2663-2670
  8. Fast response formaldehyde gas sensor for USN application vol.175, pp.None, 2010, https://doi.org/10.1016/j.snb.2012.01.004
  9. Bacteria Classification Using Electronic Nose for Diabetic Wound Monitoring vol.339, pp.None, 2010, https://doi.org/10.4028/www.scientific.net/amm.339.167
  10. Semiconductor-Type MEMS Gas Sensor for Real-Time Environmental Monitoring Applications vol.35, pp.4, 2010, https://doi.org/10.4218/etrij.13.1912.0008
  11. A novel sensor array and classifier optimization method of electronic nose based on enhanced quantum-behaved particle swarm optimization vol.34, pp.3, 2010, https://doi.org/10.1108/sr-02-2013-630
  12. Analysis of Airborne Biomarkers for Point-of-Care Diagnostics vol.19, pp.3, 2010, https://doi.org/10.1177/2211068213517119
  13. Improving the performance of electronic nose for wound infection detection using orthogonal signal correction and particle swarm optimization vol.34, pp.4, 2010, https://doi.org/10.1108/sr-10-2012-710
  14. In-vitro diagnosis of single and poly microbial species targeted for diabetic foot infection using e-nose technology vol.16, pp.None, 2010, https://doi.org/10.1186/s12859-015-0601-5
  15. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose vol.6, pp.1, 2010, https://doi.org/10.3390/bios6010004
  16. A Novel Pre-Processing Technique for Original Feature Matrix of Electronic Nose Based on Supervised Locality Preserving Projections vol.16, pp.7, 2010, https://doi.org/10.3390/s16071019
  17. Selective Detection of Target Volatile Organic Compounds in Contaminated Humid Air Using a Sensor Array with Principal Component Analysis vol.17, pp.7, 2010, https://doi.org/10.3390/s17071662
  18. Investigation of Exhaled Breath Samples from Patients with Alzheimer’s Disease Using Gas Chromatography-Mass Spectrometry and an Exhaled Breath Sensor System vol.17, pp.8, 2010, https://doi.org/10.3390/s17081783
  19. Self-Taught Learning Based on Sparse Autoencoder for E-Nose in Wound Infection Detection vol.17, pp.10, 2010, https://doi.org/10.3390/s17102279
  20. Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation vol.47, pp.13, 2010, https://doi.org/10.1039/c8cs00317c
  21. An Intelligent and Smart Environment Monitoring System for Healthcare vol.9, pp.19, 2010, https://doi.org/10.3390/app9194172
  22. A Novel Subspace Alignment-Based Interference Suppression Method for the Transfer Caused by Different Sample Carriers in Electronic Nose vol.19, pp.22, 2010, https://doi.org/10.3390/s19224846
  23. Thriving Under Stress: Pseudomonas aeruginosa Outcompetes the Background Polymicrobial Community Under Treatment Conditions in a Novel Chronic Wound Model vol.10, pp.None, 2020, https://doi.org/10.3389/fcimb.2020.569685
  24. Development of Electronic Nose for Qualitative and Quantitative Monitoring of Volatile Flammable Liquids vol.20, pp.7, 2010, https://doi.org/10.3390/s20071817