Treatment of Food Waste Leachate using Pure-Oxygen Jet Loop Reactor(JLR)

순산소 Jet 폭기 시스템을 이용한 음폐수 처리 특성

  • 윤애화 (충북대학교 환경공학과) ;
  • 박노백 (국립농업과학원 기후변화생태과) ;
  • 배종훈 (충북대학교 환경공학과) ;
  • 전항배 (충북대학교 환경공학과) ;
  • 권영배 (에이치플러스이엔지(주))
  • Received : 2010.07.07
  • Accepted : 2010.12.15
  • Published : 2010.12.15

Abstract

The removal efficiencies and a total oxygen transfer coefficient for food waste leachate(FWL) were estimated by using Jet Loop Reactor(JLR). Pure oxygen was used instead of air to improve oxygen concentration in the JLR for high total chemical oxygen demamd(TCOD) in FWL. In JLB, in order to examining the oxygen transfer characteristic, the circulation flowrate and oxygen flowrate were controlled with 7~10 L/min(1.5 L/min interval) and 0.2~0.5 L/min (0.1 L/min interval) and we experimented according to the each condition. As a result, Oxygen uptake rate(OUR) and oxygen transfer rate could be maximized than the oxygen flowrate to increase the circulation flowrate. In addition, it determined that JLR using the pure oxygen which can obtain the greatest oxygen transfer rate as it was the high-concentration organic wastewater like the food waste leachate through the continuous experiment was appropriate.

Keywords

References

  1. 김영호 (1991) 순산소활성오니법을 이용한 공단계 하수의 처리, 영남대학교 대학원 석사학위논문.
  2. 박노백, 송용효, 박준규, 전향배 (2009) Jet 폭기 시스템의 순환유량에 따른 산소전달 특성 및 순산소 적용성 검토, 한국물환경학회지, 25(6), pp.896-901.
  3. 조성웅, 이병규 (1999) 순산소 활성슬러지법을 이용한 염료 폐수처리 연구, 대한환경공학회지, 21(5), pp. 969-976.
  4. 환경부 (2006) 전국 폐기물 발생 및 처리 현황
  5. 환경부 (2007) 음식물류 폐기물 처리시설 발생폐수 육상처리 및 에너지화 종합대책(2008-2012)
  6. Boon, A. G., Ranks, N. and Hegemann, W. (1976) Oxygen Activates Sludge System. in Proceedings of series of presentations from Britain and Europe under the auspicies of the NATO CCMS Advanced Wastewater Treatment Committee, pp. 206-237.
  7. Chen, J. H.. Hsu, Y. C., Chen, Y. F., Lin, C. C. (2003) Application of gas-inducing reactor to obtain high oxygen dissolution in aeration process. Water Research. 37, pp. 2919-2928. https://doi.org/10.1016/S0043-1354(03)00084-8
  8. Farizoglu, B., Keskinler, B. (2007) Influence of draft tube cross-sectional geometry on $K_La$ and ${\varepsilon}$ ing jet loop bioreactors(JLB). Chemical Engineering J. 133. pp. 293-299. https://doi.org/10.1016/j.cej.2007.02.022
  9. Hughmark, G. A. (1967) Holdup and mass transfer in bubble columns. Ind Eng Chem Process Des Dev. 6, pp. 218-220.
  10. Kawase, Y., Hashiguchi, N. (1996) Gas-liquid mass transfer in external-loop airlift columns with Newtonian and non-Newtonian fluids. Chem Eng J. 62, pp. 35-42.
  11. Roberts, P. V., Dandllker, P. G. (1983) Mass transfer of volatile organic contaminants from aqueous solution to the atmosphere during surface aeration. Environ. Sc. Technol. 17(8), pp. 484-489. https://doi.org/10.1021/es00114a009
  12. Panja, N. C., Phaneswara Rao, D. (1993) Measurement of gas-liquid parameters in a mechanically agitated contactor. Chemical Engineering J. 52, pp. 121-129. https://doi.org/10.1016/0300-9467(93)80061-R
  13. Petruccioli, M., Cardoso Duarte, J., Eusebio, A., Federici, F. (2002) Aerobic treatment of winery wastewater using a jet-Loop activated sludge reactor. Process Biochemistry. 37, pp. 821-829. https://doi.org/10.1016/S0032-9592(01)00280-1
  14. Yagna Prasad, K., Ramanuiam, T. K. (1994) Enhancement of gas-liquid mass transfer in a modified reversed flow jet loop reactor with three-phase system. Chemical Engineering Science. 50(8), pp. 2997-3000.
  15. Zamouche, R., Bencbeikh-Lehocine, M. Meniai, A. H. (2006) Oxygen transfer and energy savings in a pilot-scale batch reactor for domes tic wastewater treatment. Desalination. 206, pp. 414-423.