Abstract
The purpose of this study was to evaluate the validity of the second-order analysis for asymmetric unbraced frame using the load amplification factor suggested by design codes. For this purpose, the first-order analysis with the B1 and B2 factors suggested by KBC 2005 and the direct analysis with the load amplification factors suggested by KBC 2009 were performed for five story - two bay and five story - four bay asymmetric unbraced steel frames. The results of the analyses were compared with the results of the second-order inelastic analysis to evaluate the validity of the suggested methods. The main parameters of the analysis were the shape of the frame, the axial load ratio of the column, the methods of analysis and the location of column. The research results show that the asymmetric shape of the frame deteriorates the validity of the factor B2 and the suggested methods. The range of error is increased in case of irregular or inclined column.
본 연구는 비대칭 비가새 골조를 대상으로 강구조 설계기준에서 제시하고 있는 하중증폭계수를 적용한 2차 해석법의 타당성을 해석적 방법을 통해 평가하는데 그 목적이 있다. 이를 위해 KBC 2005에서 제안하고 있는 B1 및 B2 계수를 적용한 2차 해석과 KBC 2009에서 제안하고 있는 하중증폭계수를 적용한 직접해석을 5층 2스팬 및 5층 4스팬 비대칭 비가새 강구조 골조에 대해 실시하고, 그 해석 결과를 2차 비탄성 해석 결과와 비교하여 기준에서 제안된 2차 해석법들을 평가하였다. 해석의 주요 변수로는 골조 형상, 기둥 축력비, 해석방법, 기둥수평위치 등이 적용되었다. 연구 결과 구조물의 비대칭성은 B2 계수 및 제안된 해석법의 유효성에 영향을 미치는 것으로 나타났으며, 특히 기둥삭제 및 경사 기둥의 경우 오차의 범위가 증가하는 것으로 나타났다.