Abstract

The water proton relaxation rates increase linearly with concentrations of contrast agents, and could be expressed as a function of the concentrations. In this paper, we have investigated MR properties of two different contrast agents, $GdCl_3$ and $CoCl_2$. Relaxivity coefficients were calculated from individual contrast agent solutions, and used for predicting relaxation rates at mixtures of two contrast agents. From the experimental results, we have discussed the feasibility of constructing water solutions with the desired relaxation times using specific mixtures of contrast agents.

Keywords

References

  1. D.F. Hansen, H. Feng, Z. Zhou, Y. Bai, L.E. Kay, J. Am. Chem. Soc. 131, 16257-16265, (2009). https://doi.org/10.1021/ja906842s
  2. P. E. Sunde, B. J. Halle, Am. Chem. Soc. 131, 18214–18215, (2009). https://doi.org/10.1021/ja908144y
  3. K.H. Chalmers, E. De Luca, N.H. Hogg, A.M. Kenwright, I. Kuprov, D. Parker, M.Botta, J.I. Wilson, A.M. Blamire, Chem. Eur. J. 16, 134–148, (2010). https://doi.org/10.1002/chem.200902300
  4. S. Dahlin, B. Reinhammar, J. Angstrom, Biochemistry 28, 7224–7233, (1989). https://doi.org/10.1021/bi00444a014
  5. D. Lee, V. Vijayan, P. Montaville, S. Becker, C. Grieginger, J. Kor. Magn. Reson. Soc.13, 15-26, (2009). https://doi.org/10.6564/JKMRS.2009.13.1.015
  6. J. E. Kirsch, Top. Magn. Reson. Imaging 1-18, (1991)
  7. C. Burtea, S. L. Laurent, V. Elst, R. N. Muller, Handbook of Experimental Pharmacology 135-165. (2008)
  8. F.-M. Eduardo, C. Juan, N.-C. Ramon, R. Ricardo, J. Am. Chem. Soc. 129, 15164-15173, (2007). https://doi.org/10.1021/ja0737117
  9. H.B. Na, J.H. Lee, K. An, Y.I. Park, M. Park, I.S. Lee, D.H. Nam, S.T. Kim , S.H.Kim, S.W. Kim, K.H. Lim, K.S. Kim, S.O. Kim, T. Hyeon, Angew. Chem. Int. Ed. Engl. 46 , 5397-5401, (2007). https://doi.org/10.1002/anie.200604775
  10. J.-H. Lee, Y.-M. Huh, Y.-w. Jun, J.-w. Seo, J.-t. Jang, H.-T. Song, S. Kim, E.-J. Cho, H.-G. Yoon, J.-S. Suh, Cheon, J. Nat. Med. 13, 95-99, (2007). https://doi.org/10.1038/nm1467
  11. A. A. Neves, A. S. Krishnan, M. I. Kettunen, D.-E. Hu, M. M. De Backer, B.Davletov, K. M. Brindle, Nano Lett. 7 , 1419-1423 (2007) https://doi.org/10.1021/nl070126v
  12. P. Caravan, J. J. Ellison, T. J. McMurry, R. B. Lauffer, Chem. Rev. 99, 2293-2352,(1999) https://doi.org/10.1021/cr980440x
  13. R. B. Lauffer, Chem. Rev. 87, 901-927, (1987). https://doi.org/10.1021/cr00081a003
  14. J. L. Barnhart, R. N. Berk, Invest. Radiol. 21, 132–136, (1986). https://doi.org/10.1097/00004424-198602000-00009
  15. M. J. Quast, H. Neumeister, E. L. Ezell, B. U. Budelmann, Magn. Reson. Med. 45, 575–579, (2001). https://doi.org/10.1002/mrm.1078
  16. G. Otting, Journal of Progress in Nuclear Magnetic Resonance Spectroscopy 31, 259-285, (1997). https://doi.org/10.1016/S0079-6565(97)00012-5
  17. N. Matubayasi, C. Wakai, M. Nakahara, Phys. Rev. Letters 78, 2573-2576, (1997). https://doi.org/10.1103/PhysRevLett.78.2573
  18. M. Marzelli, K. Fischer, Y. B. Kim, R. V. Mulkern, S.-S. Yoo, H. Park, Z.-H. Cho, Int. J. Imaging Syst. Technol. 18, 79-84, (2008). https://doi.org/10.1002/ima.20142
  19. X.-A. MAO, C.-H. YE, Concepts Magn. Reson. 9, 173-187, (1997). https://doi.org/10.1002/(SICI)1099-0534(1997)9:3<173::AID-CMR4>3.0.CO;2-W
  20. S. Lusse, K. Arnold, Macromolecules 29, 4251-4257, (1996). https://doi.org/10.1021/ma9508616
  21. W. S. Warren, S. L. Hammes, J. L. Bates, J. Chem. Phys. 91, 5895-5904, (1989). https://doi.org/10.1063/1.457458
  22. K.-C. Chung, S. Ahn, J. Kor. Magn. Reson. Soc. 10, 46-58, (2006).
  23. H. Y. Carr, E. M. Purcell, Phys. Rev. 94, 630–638, (1954). https://doi.org/10.1103/PhysRev.94.630
  24. S. Meiboom, D. Gill, Rev. Sci. Instr. 29, 688–691, (1958). https://doi.org/10.1063/1.1716296
  25. S. H. Koenig, K. E. Kellar, Acad. Radiol. 3, S273-S276, (1996). https://doi.org/10.1016/S1076-6332(96)80555-1

Cited by

  1. Stability and Trapping of Magnetic Resonance Imaging Contrast Agents During High-Intensity Focused Ultrasound Ablation Therapy vol.48, pp.7, 2013, https://doi.org/10.1097/RLI.0b013e31829aae98