참고문헌
- F. Hanisch, P. Maier, S. Okada, H. Onbacherh. "Effects of Radiation types and dose rates on selected Cable-insulating materials," Raiat. Phys. Chem., Vol 30, No 1, pp 1-9, 1987.
- IAEA, "Assessment and management of ageing of major nuclear power plant components important to safety: Incontainment instrumentation and control cables", IAEATECDOC- 1188, International Atomic Energy Agency, 2000.
- K. Mehta and R. Girzikowsky, "Reference Dosimeter system of the IAEA", Radat. Phys. Chem., Vol 46, No. 4-6, pp 1247-1250, 1995. https://doi.org/10.1016/0969-806X(95)00362-2
- J. M. Dolo, N. lecerf and I. Tartes, "Progress in Quality Control of Alanine Dosimeters", Appl. Radiat. Isot., Vol. 47, No.11/12, pp 1165-1168, 1996. https://doi.org/10.1016/S0969-8043(96)00204-7
- ASTM E 1607-96, Standard practice for use of the Alanine- EPR dosimetry system, American National Standard Institute, 1996.
- E. Malinen, M. Z. Heydari, E. Sagstuen and E. O. Hole, "Alanine Radicals, Part 3: Properties of the components contributing to the EPR spectrum of x-irradiatied alanine dosimeters", Radiation Research Vol 159, pp 23-32, 2003. https://doi.org/10.1667/0033-7587(2003)159[0023:ARPPOT]2.0.CO;2
- M. Z. Heydari, E. Malinen, E. O. Hole and E. Sagstuen, "Alanine Radicals, Part 2: The composite Poly crystalline Alanine EPR Spectrum Studied by ENDOR, Thermal Annealing and Spectrum Simulations", J. phys. chem., Vol 106, pp 8971-8977, 2002. https://doi.org/10.1021/jp026023c
- E. Malinen, E. A. Hult, E. O. Hole and E. Sagstuen, "Alanine Radicals, Part 4: Relative Amounts of Radical Species in Alanine Dosimeters after Exposure to 6-19Mev Electrons and 10Kv-15Mv photons", Radiation Research, Vol 150, pp 149-153, 2003.
- B. Ciesieelski, L.Wielopolski, "The effects of boron on the electron paramagnetic resonance spectra of alanine irradiated with thermal neutrons", Radiation research, Vol 144, pp 59-63, 1995. https://doi.org/10.2307/3579236
- B. Ciesielski, L.Wielopolski, "The effects of Dose and Radiation Quality on the shape and Power Saturation of the EPR Signal in Alanine", Radiation research, Vol 140, pp 105-111, 1994. https://doi.org/10.2307/3578575
- B. Ciesielski, Z. Stuglik, L. Wielopolski and I. Zvara, "The effect of High-Linear Energy Transfer Ions on the Electron Paramagnetic Resonance Signal in Alanine", Radiation Research, Vol 150, pp 469-474, 1998. https://doi.org/10.2307/3579667
- V. Nagy, J. M. Puhl, M. F. Desrosiers, "Advancements in accuracy of the alanine dosimetry system: Part 2: The influence of the irradiation temperature", Radiation Physics and Chemistry, Vol 57, pp 1-9, 2000. https://doi.org/10.1016/S0969-806X(99)00339-4
- A. Cecilla, S. Baccaro, A. Cemmi, V. Colli, G. Rosi and L. Scolari, "Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy(NCT)", Radiation Protection Dosimetry, Vol 110, Issue 1-4, pp 637-640, 2004. https://doi.org/10.1093/rpd/nch108