High Frequency Ultrasound and Its Applications to Animal and Human Imaging Focusing on Vessel and Blood

고주파 초음파의 그 응용: 혈관과 혈액을 중심으로한 동물과 인체 영상

  • Bok, Tae-Hoon (Department of Ocean System Engineering, College of Ocean Science, Jeju National University) ;
  • Paeng, Dong-Guk (Department of Ocean System Engineering, College of Ocean Science, Jeju National University)
  • Received : 2010.06.09
  • Accepted : 2010.06.28
  • Published : 2010.06.30

Abstract

In the diagnostic ultrasound (US) transducer technology, the high frequency US(HFUS) transducer over 20 MHz is one of the current issues to be pursued for better resolution with the expense of penetration. HFUS single element transducers and the mechanical scanning systems for imaging are reviewed, and HFUS array transducers are also briefly summarized. HFUS applications such as the human applications in ophthalmology and dermatology and small animal applications for research purposes are reviewed with vascular and blood imaging in this paper.

Keywords

References

  1. F. S. Foster. J. Mehi, M. Lukacs, D. Hirson, C. White, C. Chaggares, and A. Needles, "A New 15-50 MHz Array-Based Micro-Ultrasound Scanner for Preclinical Imaging," Ultrasound Med. Biol., vol. 35, no. 10, pp. 1700-1708, 2009. https://doi.org/10.1016/j.ultrasmedbio.2009.04.012
  2. T. A. Ritter, T. R. Shrout, R. Tutwiler, and K. K. Shung, "A 30-MHz piezo-composite ultrasound array for medical imaging applications," IEEE Trans. Ultrason, Ferroelectr. Freq. Control, vol. 49, no. 2, pp. 217-230, 2002. https://doi.org/10.1109/58.985706
  3. J, M, Cannata, J. A. Williams, Z. Qila, T. A. Ritter, and K. K. Shung, "Development of a 35-MHz piezo-composite ultrasound array for medical imaging," IEEE Trans. Ultrason, Ferroelectr. Freq. Control, vol, 53, no. 1, pp. 224-236, 2006. https://doi.org/10.1109/TUFFC.2006.1588408
  4. G. R. Lockwood, D. H. Turnbull, and F. S. Foster, "Fabrication of high frequency spherically shaped ceramic transducers," IEEE Trans, Ultrason. Ferroelectr. Freq. Control, vol.41, no. 2, pp. 231-235, 1994. https://doi.org/10.1109/58.279136
  5. M. J. Zipparo, K. K. Shung, and T. R. Shrout, "Piezoceramics for high-frequency (20 to 100 MHz) single-element imaging transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol.44, no. 5, pp. 1038-1048, 1997. https://doi.org/10.1109/58.655629
  6. M. D. Sherar and F. S. Foster, "The design and fabrication of high frequency poly(vinylidene fluoride) transducers," Ultrason. Imaging, vol. 11,no. 2, pp. 75-94, 1989. https://doi.org/10.1016/0161-7346(89)90001-1
  7. K. A. Snook, Z. Jian-Zhong, C. H. F. Alves, J. M. Cannata, C. Wo-Hsing, R. J. Meyer, Jr., T. A. Ritter, and K. K. Shung, "Design. tabrication, and evaluation of high frequency, single-element transducers incorporating different materials," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, no. 2, pp. 169-176, 2002. https://doi.org/10.1109/58.985701
  8. D. A, Knapik, B, Starkoski, C. J. Pavlin, and F. S. Foster, "A 100-200 MHz ultrasound biomicroscope," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 47, no. 6, pp. 1540-1549, 2000. https://doi.org/10.1109/58.883543
  9. J. M. Cannata, T. A. Ritter, C. Wo-Hsing, R. H. Silverman, and K. K. Shung, "Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications," IEEE Trans. Ultrason. Ferroelectr, Freq. Control, vol. 50, no. 11, pp. 1548-1557, 2003. https://doi.org/10.1109/TUFFC.2003.1251138
  10. D.-G, Paeng, J. H. Chang, R. Chen, M. S. Humayun, and K. K. Shung, "Feasibility of rotational scan ultrasound imaging by an angled high frequency transducer for the posterior segment of the eye," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no.,3, pp. 676-680, 2009. https://doi.org/10.1109/TUFFC.2009.1084
  11. Q. Zhou, X. Xu, E. L. Gottlieb, S. Lei, J. M. Cannata, H. Ameri, M. S. Humayun, H. Pengdi, and S. K. Shung, "PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 3, pp. 668-675, 2007. https://doi.org/10.1109/TUFFC.2007.290
  12. X. Xu, Q. Zhou, H. Ameri, E. J. Gottlieb, B. Lai, J. T. Yen, J. M. Cannata, H. Pengdi, M. S. Humayun, and K. K. Shung. "High-Frequency Pulsed-Wave Ultrasound Doppler System for Biomedical Applications with PMN-PT Needle Transducer and 30 MHz Linear Array," Ultrasonics Symposium, 2006. IEEE. 2006.
  13. S. Ping, Z. Qila, Z. Benpeng, W. Dawei, H. Changhong, J. M. Cannata, T. Jin, H. Pengdi, W. Gaoleng, and K. K. Shung, "Design and fabrication of PIN-PMN-PT single-crystal high-frequency ultrasound transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 12, pp. 2760-2763, 2009. https://doi.org/10.1109/TUFFC.2009.1367
  14. F. S. Foster, G. R. Lockwood, L. K. Ryan, K. A. Harasiewicz, L. Berube, and A. M. Rauth, "Principles and applications of ultrasound backscatter microscopy," IEEE Trans. Ultrason. Ferroelectr. Freq Control, vol. 40, no. 5, pp. 608-617, 1993. https://doi.org/10.1109/58.238115
  15. G. R. Lockwood, D. H. Turnball, D. A. Christopher, and F. S. Foster, "Beyond 30 MHz [applications of high-frequency ultrasound imaging]," IEEE Eng. Med. Biol. Mag., vol. 15, no. 6, pp. 60-71, 1996. https://doi.org/10.1109/51.544513
  16. R. H. Silverman, D. Z. Reinstein, T. Raevsky, and D. J. Coleman, "Improved system for sonographic imaging and biometry of the cornea," J. Ultrasound Med., vol. 16, no.2, pp. 117-124, 1997. https://doi.org/10.7863/jum.1997.16.2.117
  17. M. Eberle, "The latest in electronic imaging," Seminars in interventional cardiology, vol. 2, no., 19-23, 1997.
  18. K. Yokosawa, R. Shinomura, S. Sano, Y. lto, S. Ishikawa, and Y. Sato, " A 120-MHz Ultrasound Probe for Tissue lmaging," Ultrason. Imaging, vol. 18, no. 4, pp. 231-239, 1996. https://doi.org/10.1006/uimg.1996.0013
  19. T. A. Ritter. T. R. Shrout, R. Tutwiler, and K. K. Shung, "A 30-MHz piezo-composite ultrasound array for medical imaging aplications," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, no. 2, pp. 217-230, 2002. https://doi.org/10.1109/58.985706
  20. H. H. Kim, J. H. Chang, J. M. Cannata, and K. K. Shung. "Design of 20 MHz Convex Array Transducers for High Frequency Ophthalmic Imaging," Ultrasonics Symposium, 2007. IEEE. 2007.
  21. H. H. Kim, J. M. Cannata, J. A. Williams, J. H. Chang, and K. K. Shung, "Fabrication of 20 MHz convex array fransducers for high frequency ophthalmic imaging," Ultrasonics Symposium (IUS), 2009 IEEE International. 2009.
  22. A. M. Y. Cheung, A. S. Brown, L. A. Hastie, V. Cucevic, M. Roy, J. C. Lacefield, A. Fenster, and F. S. Foster, "Three-dimensional ultrasound biomicroscopy for xenograft growth analysis," Ultrasound Med. Biol., vol. 31, no. 6, pp. 865-870, 2005. https://doi.org/10.1016/j.ultrasmedbio.2005.03.003
  23. B, Martin-McNulty, J. Vincelette, R. Vergona, M. E, SUllivan, and Y.-X. Wang, "Noninvasive measurement of abdominal aortic aneurysms in intact mice by a high-frequency ultrasound imaging system," Ultrasound Med, Biol., vol. 31, no. 6, pp. 745-749, 2005. https://doi.org/10.1016/j.ultrasmedbio.2005.02.012
  24. C. Barisione, R. Charnigo, D. A. Howatt, J. J. Moorleghen, D. L. Rateri, and A. Daugherty, "Rapid dilation of the abdominal aorta during infusion of angiotensin II detected by noninvasive high-frequency ultrasonography," J. Vasc. Surg., vol. 44, no. 2, pp. 372-376, 2006. https://doi.org/10.1016/j.jvs.2006.04.047
  25. Y.-X. J. Wang, G. Betlon, E. Floettmann, E. Fantham, and G. Ridgwell, "Imaging Kidney in Conscious Rats with High-Frequency Ultrasound and Detection of Two Cases of Unilateral Congenital Hydronephrosis." Ultrasound Med. Biol., vol. 33, no. 3, pp. 483-486, 2007. https://doi.org/10.1016/j.ultrasmedbio.2006.08.010
  26. A. Razuvaev, K. Lund, J. Roy, U. Hedin, and K. Caidahl, "Noninvasive real-time imaging of intima thickness after rat carotid artery balloon injury using ultrasound biomicroscopy," Atherosclerosis, vol. 199, no. 2, pp. 310-316, 2008. https://doi.org/10.1016/j.atherosclerosis.2007.11.035
  27. Y.-S. Choi. H.-J. Youn, J.-S. Youn, C.-S. Park, Y.-S. Oh, and W.-S. Chung, "Measurement of the Intimal Thickness of the Carotid Artery: Comparison Between 40 MHz Ultrasound and Histology in Rats," Ultrasound Med. Biol., vol. 35, no. 6, pp. 962-966, 2009. https://doi.org/10.1016/j.ultrasmedbio.2008.12.004
  28. D. P. Kuttler, "Ultrasound imaging of regeneraling rat sciatic nerves in situ," Journal of Neuroscience Methods, vol. 188, no. 2, pp. 276-279, 2010. https://doi.org/10.1016/j.jneumeth.2010.02.023
  29. E. B. Neufeld, Z.-X. Yu, D. Springer. Q. Yu, and R. S. Balaban, "The renal artery ostium flow diverter: Structure and potential role in alherosclerosis." Atherosclerosis, vol. in Press, Corrected Proof, no. 2010.
  30. Y. Li, C. D. Garson, Y. Xu, R. J. Beyers, F. H. Epstein, B. A. French, and J. A. Hossack, "Quantification and MRI Validation of Regional Contractile Dysfunction in Mice Post Myocardial Infarction Using High Resolution Ultrasound," Ultrasound Med. Blol., vol. 33, no. 6, pp. 894-904, 2007. https://doi.org/10.1016/j.ultrasmedbio.2006.12.008
  31. K, Fujikura, J. Luo, V. Gamarnik, M. Pernot, R. Fukumoto, M. D. Tilson, and E. E. Konofgou, "A Novel Noninvasive Technnique for Pulse-Wave lmaging and Characterization of Clinically-Significant Vascular Mechanical Properties In Vivo," Ultrason. Imaging, vol. 29, no., pp. 137-154, 2007. https://doi.org/10.1177/016173460702900301
  32. J. Luo, K. Fujikura, S. Homma, and E. E. Konofagou, "Myocardial Elastography at Both High Temporal and Spatial Resolution for the Detection of Infarcts," Ultrasound Med. Biol., vol. 33, no. 8, pp. 1206-1223, 2007. https://doi.org/10.1016/j.ultrasmedbio.2007.01.019
  33. K. D. Wallace, J. N. Marsh, S. L. Baldwin, A. M. Connolly, R. Keeling. G, M. Lanza. S. A. Wickline, and M. S. Hughes, "Sensiive Ultrasonic Delineation of Steroid Treatment in Living Dystrophic Mice with Energy-Based and Entropy-Based Radio Frequency Signal Processing," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 11, pp. 2291-2299, 2007. https://doi.org/10.1109/TUFFC.2007.533
  34. E. E. Konotagou, J. Luo, D. Saluja, D. O. Cervantes, J. Coromilas, and K. Fujikura, "Noninvasive electromechanical wave imaging and conduction-relevant velocity estimation in vivo," Ultrasonics, vol. 50, no. 2, pp. 208-215, 2010. https://doi.org/10.1016/j.ultras.2009.09.026
  35. S. Sirsi, J. Feshitan, J. Kwan, S, Homma, and M. Borden, "Effect of Microbubble Size On Fundamental Mode High Frequency Ultrasound Imaging In Mice," Ultrasound Med. Biol.,vol. In Press, Corrected Proof, no. 2010.
  36. G. H. Mundt and W. F. Hughes, "Ultrasonics in ocular diagnosis," Am. J. Ophthalmol., vol. 42, no., pp. 488-498, 1956. https://doi.org/10.1016/0002-9394(56)90411-1
  37. I. Wada, "Ultrasound biomicroscopic corneal thickness measurement for corneal thickness mapping," Jpn. J. Ophthalmol., vol. 41, no, 1 pp. 12-18, 1996.
  38. R. C. Gentile, D. M. Berinstein, J. Liebmann, R. Rosen, Z. Stegman, C. Tello, J. B. Walsh, and R. Ritch, "High-resolution ultrasound biomicroscopy of the pars plana and peripheral retina, Historical vignette," Ophthalmology, vol. 105, no. 3, pp, 478-484, 1998. https://doi.org/10.1016/S0161-6420(98)93031-7
  39. H. Ishikawa, K Esaki, J. M. Liebmann, Y Uji, and R. Ritch, "Ultrasound Biomicroscopy Dark Room Provocative Testing: A Ouantitative Method for Estimating Anterior Chamber Angle Width," Jpn, J. Ophthalmol.,vol. 43, no. 6, pp. 526-534, 1999. https://doi.org/10.1016/S0021-5155(99)00139-2
  40. T. S. Dietlein, B. F. Engels, P. C. Jacobi, and G. K. Krieglstein, "Ultrasound biomicroscopic patterns after glaucoma surgery in congenital glaucoma," Ophthalmology, vol. 107, no. 6, pp. 1200-1205, 2000. https://doi.org/10.1016/S0161-6420(00)00075-0
  41. K. Inazumi, D. Takahashi, T. Taniguchi, and T. Yamamoto. "Ultrasound Biomicroscopic Classification of Zonules in Exfoliation Syndrome," Jpn. J. Ophthalmol., vol. 46, no. 5, pp. 502-509, 2002. https://doi.org/10.1016/S0021-5155(02)00540-3
  42. M. Sato, H. Terasaki, E, Amano, Y, Okamoto, and Y. Miyake, "Ultrasound Biomicroscopic Findings in Hallerman-Streiff Syndrome," Jpn. J. Ophthalmol., vol. 46, no. 4, pp. 451-454, 2002. https://doi.org/10.1016/S0021-5155(02)00530-0
  43. D. J. Weisbrod, C. J. Pavlin, K. Emara, M. A. Mandell, J. McWhae, and E. R. Simpson, "Small Ciliary Body Tumors: Ultrasound Biomicroscopic Assessment and Follow-up of 42 Patients," Am. J. Ophthalmol., vol. 141, no. 4, pp. 622-628, 2006. https://doi.org/10.1016/j.ajo.2005.11.006
  44. D. J, Weisbrod, C. J. Pavlin, W. Xu, and E. R. Simpson, "Long-term Follow-up of 42 Patients with Small Ciliary Body Tumors with Ultrasound Biomicroscopy," Am. J. Ophthalmol. vol. 149, no. 4, pp. 616-622, 2010. https://doi.org/10.1016/j.ajo.2009.11.021
  45. J. Oh, H.-H. Shin, J.-H. Kim, H.-M. Kim, and J.-S. Song, "Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound Biomicroscopy," Ophthalmology, vol. 114, no. 9, pp. 1685-1688, 2007. https://doi.org/10.1016/j.ophtha.2006.12.018
  46. C. J. Pavlin, L. M. V squez, R. Lee, E, R. Simpson, and J. J. K. Ahmed, "Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy in the Imaging of Anterior Segment Tumors," Am. J. Ophthalmol., vol. 147, no. 2, pp. 214-219. e2, 2009.
  47. I. M. Henzan, A. Tomidokoro, C. Uejo, H. Sakai, S. Sawaguchi, A. lwase, and M. Araie, "Ultrasound Biomicroscopic Configurations of the Anterior Ocular Segment in a Population- Based Study: The Kumejima Study," Ophthalmology, vol. In Press, Corrected Proof. no. 2010.
  48. J. J. Mura, C. J. Pavlin, G. P. Condon, G. W. Belovay, C. F. Kranemann, H. lshikawa, and I. I. K. Ahmed, "Ultrasound Biomicroscopic Analysis of lris-Sutured Foldable Posterior Chamber Intraocular Lenses," Am. J. Ophthalmol., vol. 149, no. 2, pp. 245-252. e2, 2010. https://doi.org/10.1016/j.ajo.2009.08.022
  49. D. A. Perednia, " What dermatologists should know about digital imaging," Journal of the American Academy of Dermatology, vol. 25, no. 1, Part 1. pp. 89-108, 1991. https://doi.org/10.1016/0190-9622(91)70178-5
  50. C. A. Gropper, M. J. Stiller, J. L. Shupack, J. Driller, M. Rorke, and F. Lizzi, "Diagnostic high resolution ultrasound in dermatology," Int. J. Dermatol., vol. 32, no., pp. 243-250, 1993. https://doi.org/10.1111/j.1365-4362.1993.tb04261.x
  51. D. H. Turnbull, B. G. Starkoski, K. A. Harasiewicz, J. L. Semple, L. From, A. K. Gupta, D.N. Sauder, and F. S. Foster, "A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging," Ultrasound Med. Biol. vol. 21, no. 1, pp. 79-88, 1995.
  52. H. Lopez, J. Z, Beer, S. A. Miller, and B. Z. Zmudzka, "Ultrasound measurements of skin thickness after UV exposure: a feasibility study," Journal of Photochemistry and Photobiology B: Biology, vol. 73, no. 3, pp. 123-132, 2004. https://doi.org/10.1016/j.jphotobiol.2003.11.004
  53. Y. P. Huang, Y. P. Zheng, S. F. Leung, and A. P. C. Choi, "High Frequency Ultrasound Assessment of Skin Fibrosis: Clinical Results," Ultrasound Med. Biol.,vol. 33, no. 8, pp. 1191-1198, 2007. https://doi.org/10.1016/j.ultrasmedbio.2007.02.009
  54. J. L. Tedstone, S. M. Richards, R. D. Garman, and M. C. Ruzek, "Ultrasound Imaging Accurately Detects Skin Thickening in a Mouse Scleroderma Model," Ultrasound Med. Biol.,vol. 34, no. 8, pp. 1239-1247. 2008. https://doi.org/10.1016/j.ultrasmedbio.2008.01.013
  55. P.-G. Sator, S. Radakovic, K. Schulmeister, H. H nigsmann, and A. Tanew, "Medium-dose is more effective than low-dose ultraviolet Al phototherapy for localized scleroderma as shown by 20-MHz ultrasound assessment," Journal of the American Academy of Dermatology, vol. 60, no. 5, pp. 786-791, 2009. https://doi.org/10.1016/j.jaad.2008.12.013
  56. X. Wortsman and J. Wortsman, "Clinical usefulness of variablefrequency ultrasound in localized lesions of the skin," Journal of the American Academy of Dermatology, vol. 62, no. 2, pp. 247-256, 2010. https://doi.org/10.1016/j.jaad.2009.06.016
  57. S. Goldberg, A. Colombo, S. Nakamura, Y. Almagor, L. Maiello, and J. Tobis, "Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents," J Am Coll Cardiol, vol. 24, no. 4, pp. 996-1003, 1994. https://doi.org/10.1016/0735-1097(94)90861-3
  58. A. Colombo, P. Hall, S. Nakamura, Y Almagor, L. Maiello, G. Martini, A. Gaglione, S. L. Goldberg, and J. M. Tobis, "Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance", Circulation, vol. 91, no. 6, pp. 1676-1688, 1995. https://doi.org/10.1161/01.CIR.91.6.1676
  59. I. Moussa, C. Di Mario, L. Di Francesco, B. Reimers, S. Blengino, and A. Colombo, "Subacute Stent Thrombosis and the Anticoagulation Controversy: Changes in Drug Therapy, Operator Technique, and the Impact of Intravascular Ultrasound," The American Journal of Cardiology, vol. 78, no. 3, Supplement 1, pp. 13-17, 1996. https://doi.org/10.1016/S0002-9149(96)00486-9
  60. V. Klauss, J. Rieber, P. Ubefuhr, K. Theisen, and H. Mudira, "Qualitative and quantitative assessment of cardiac allograft vasculopathy by intravascular ultrasound." Transplantation Proceedings, vol. 2, no., pp. 1975-1976, 1995.
  61. P. J. Fitzgerald, M. Belef. A. J. Connolly, K. Sudhir, and P. G. Yock, "Design and initial testing of an ultrasound-guided directional atherectomy Device," American heart journal, vol. 129, no. 3, pp. 593-598, 1995. https://doi.org/10.1016/0002-8703(95)90289-9
  62. M. Kawata, T. Okada, N. Igarashi, K. Okajima, Y. Domoto, and T. Mizutani, "Assessment of intravascular ultrasound- bearing balloon catheter-guided percutaneous transluminal coronary angioplasty and stenting," Heart and Veseels, vol. Suppl 12, no., pp. 185-187, 1997.
  63. D. Liang and B. Hu, "Forward-looking catheters," Seminars in Interventional Cardiology, vol. 2, no. 1, pp. 75-87. 1997.
  64. C. von Birgelen, R. Erbel,. C. Di Mario, W. Li, F. Prati., J. Ge. N. Bruining, G. G rge, C. Stager, P. Serruys, and e. al., "Three-dimensional reconstruction of coronary arteries with intravascular ultrasound," Herz, vol. 20, no. 4, pp. 277-289, 1995.
  65. C. von Birgelen, W. Li, N. Bom, and P. Serruys, "Quantitative three-dimensional intravascular ultrasound," Seminars in Interventional cardiology, vol. 2, no.1, pp. 25-32, 1997.
  66. E. Cespedes, C. de Korte, A. van der Steen, C. von Birgelen, and C. Lancee, "Intravascular elastography: principles and potentials," Seminars in interventional cardiology vol. 2, no., pp. 55-62, 1997.
  67. C. L. de Korte, A. F. W. van der Steen, E. J. C spedes, and G. Pasterkamp, "Intravascular Ultrasound Elastography in Human Arteries: Initial Experience In Vitro," Ultrasound Med. Biol., vol. 24, no. 3, pp. 401-408, 1998. https://doi.org/10.1016/S0301-5629(97)00280-9
  68. F. Foster, D. Knapik, J. Machado, J. Gallet, L. Ryan, and S. Nissen, "High frequency intracoronary ultrasound imaging," Seminars in interventional cardiology, vol. 2, no., pp. 33-41, 1997.
  69. F. S. Foster, C. J. Pavlin, K. A. Harasiewicz, D. A. Christopher, and D. H. Turnbull, "Advances in ultrasound biomicroscopy," Ultrasound Med. Biol., vol. 26, no. 1, pp. 1-27, 2000. https://doi.org/10.1016/S0301-5629(99)00096-4
  70. C. Di Mario, S. The, S. Madretsma, R. van Suylen, R. Wilson, N. Bom, P. Serruys, E. Gussenhoven, and R. JR, "Detection and characterization of vascular lesions by intravascular ultrasound: an in vitro study correlated with histology," Journal of the American Society of Echocardiography, vol. 5, no. 2, pp. 135-146, 1992. https://doi.org/10.1016/S0894-7317(14)80543-9
  71. G, Lockwood, L. Ryan, A. Gotlieb, E. Lonn, J. Hunl, P. Liu, and F. Foster, "In vitro high resolution intravascular imaging in muscular and elastic arteries," J Am Coll Cardiol, vol. 20, no. 1, pp. 153-160, 1992. https://doi.org/10.1016/0735-1097(92)90152-D
  72. A, J. Martin, L. K. Ryan, A. J. Gollieb, R. M. Henkelman, and F. S. Foster, "Arterial imaging: comparison of high-resolution US and MR imaging with histologic correlation," Radiographics, vol. 17, no. 1, pp. 189-202, 1997. https://doi.org/10.1148/radiographics.17.1.9017808
  73. F. S. Foster, H Obara, T. Bloomfield, L. K. Ryan, and G. R. Lockwood. "Ultrasound backscatter from blood in the 30 to 70 MHz frequency range," Ultrasonics Symposium,1994. Proceedings., 1994 IEEE. 1994.
  74. W. Li, C. Lancee, A. van der Steen, E. Gussenhoven, and N. Bom. "Blood velocity estimation with high frequency intravascular ultrasound," Ultrasonics Symposium, 1996. Proceedings., 1996 IEEE. 1996.
  75. S.-H. Wang and K. K. Shung, "In vivo measurements of utlrasonic backscattering in blood," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 2, pp. 425-431, 2001. https://doi.org/10.1109/58.911725
  76. D. A. Christopher, P. N. Burns, J. Armstrong, and F. S. Foster, "A high-frequency continuous-wave Doppler ultrasound system for the detection of blood flow in the nicrocirculation," Ultrasound Med. Biol., vol. 22, no. 9, pp. 1191-1203, 1996. https://doi.org/10.1016/S0301-5629(96)00153-6
  77. D. A. Christopher, P. N. Burns, B. G. Strakoski, and F. S. Foster, "A high-frequency pulsed-wave Doppler ultrasound system for the detection of blood flow in the microcirculation," Ultrasound Med. Biol., vol. 22, no. 9, pp. 1191-1203, 1996. https://doi.org/10.1016/S0301-5629(96)00153-6
  78. N. Matsuoka, D.-G. Paeng, R. Chen, H. Ameri, W. Abdallah, Q. Zhou, A. Fawzi, K. Shung, and M. Humayun, "Ultrasonic Doppler measurements of blood flow velocity of rabbit retinal vessels using a 45-MHz needle transducer," Graefe's Archive for Clinical and Experimental Ophthalmology, vol. 248, no. 5, pp. 675-680, 2010. https://doi.org/10.1007/s00417-009-1298-9
  79. X. Xu, L. Sun, J. M. Cannata. J. T. Yen. and K. K. Shung, "High-Frequency Ultrasound Doppler Systerm for Biomedical Applications with a 30-MHz Linear Array," Ultrasound Med. Biol., vol. 34, no. 4, pp. 638-646, 2008. https://doi.org/10.1016/j.ultrasmedbio.2007.09.012
  80. L. C. Nguyen, F. T. H. Yu, and G, Cloutier, "Cyclic Changes in Blood Echogenicity Under Pulsatile Flow Are Frequency Dependent," Ultrasound Med. Biol., vol. 34, no. 4, pp. 664-673, 2008. https://doi.org/10.1016/j.ultrasmedbio.2007.10.002
  81. C.-C. Huang, "Cyclic Variations of High-Frequency Ultrasonic Backscattering From Blood Under Pulsatile Flow," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 8, pp.1677-1688, 2009. https://doi.org/10.1109/TUFFC.2009.1232
  82. Y, Sugata and K. Nemoto, "Intravascular Spontaneous Echo Contrast in Superficial Veins: Enhancement by Compression of the Central Side of the Vein and Intake of Food", Journal of Medical Ultrasonics, vol. 31, no. 3, pp. J179-J182, 2004.
  83. T.-H. Bok, y,Li, D,-G, Paeng, and H.-J, Kang. "Observation of the cyclic variation of echogenicity in the radial artery using ultrasound biomicroscopy," Acoustical Society of Korea Conference. 2010.