DOI QR코드

DOI QR Code

Analysis on Parameter Detuning of Induction Motor Drives in Field Weakening Region

약계자영역에서 유도전동기 고정자자속기준제어의 파라미터 비동조 영향 분석

  • 신명호 (서울과학기술대학교 전기공학과)
  • Received : 2010.06.14
  • Accepted : 2010.07.09
  • Published : 2010.09.30

Abstract

The selection of flux level in the maximum torque control of stator flux-oriented induction motor drives in the field weakening region is dependent on stator resistance and inductances. This paper presents parameter detuning effects of stator flux-oriented control drives in the field weakening region. The detuning effects of stator resistance and rotor leakage inductance are analyzed. The decrease of torque and the flux control lost by the detuning of inductance are shown in the simulation results.

Keywords

References

  1. X. X. Xu, R. D. Doncker, and D. W. Novotny, "A stator flux oriented induction machine drive," in Proc. IEEE PESC’'88, 1988, pp. 870-876.1992. https://doi.org/10.1109/PESC.1988.18219
  2. M.-H. Shin, D.-S. Hyun, and S.-B. Cho "Maximum Torque Control of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region, IEEE Trans. IA, vol. 38, no.1, pp.117-122, 2002.
  3. M.-H. Shin and D.-S. Hyun, "Online Identification of Stator Transient Inductance in Rotor-Flux-Oriented Induction Motor Drive", IEEE Trans. IE, vol. 54, no.4, pp.2018-2023, 2007.
  4. M.-H. Shin, D. S. Hyun, S. B. Cho, and S. Y. Choe, An Improved Stator Flux Estimation for Speed Sensorless Stator Flux Orientation Control of Induction Motors, IEEE Trans. PE, vol. 15, no. 2, pp. 312-318, 2000.

Cited by

  1. Analysis on Parameter Detuning of Induction Motor Drives in Constant Torque Region vol.26, pp.11, 2012, https://doi.org/10.5207/JIEIE.2012.26.11.081
  2. Errors of Proportional Shifting due to Simplified Equivalent Circuit of a 3-Phase Induction Motor vol.27, pp.1, 2013, https://doi.org/10.5207/JIEIE.2013.27.1.109