Abstract

This paper investigates the behavior of precast concrete (PC) shear walls with a new vertical connections for a fast remodeling construction. The C-type vertical connections for the PC wall systems are proposed for transfer of bending moment between top and bottom walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing action. The proposed vertical connections allows easy fabrication thanks to slots at the edges of wall in opposite directions. The plane PC wall systems subject to lateral load are compared with ordinary wall systems by investigating the effects of connection on the stiffness, strength, ductility, and failure modes of whole systems. The load-displacement relationship and influence of premature failure of connections are examined. The experimental test showed that the longitudinal reinforcing steel bars placed at the edges of walls yielded first and the ultimate deformation were terminated due to premature failure of connections. The diagonal reinforcements for efficient shear transfer in the walls were not effective. The strength and deformation obtained through the section analysis were generally in agreement with the experimental data, and indicated that. Gap opening contributed to the deformation behavior more than any other factors.

이 논문은 새로운 수직 접합부를 가진 프리캐스트 벽체의 거동에 관한 연구이다. PC 벽체를 이용한 리모델링 건설을 위해서는 효율적이고 경제적인 조립 방법이 필요하다. C형 수직 접합부를 가진 PC 벽체 시스템은 수직방향의 벽체 사이의 휨모멘트를 전달하도록 하고, 반면에 벽체 중심에 있는 전단키는 전단력을 부담하도록 하였다. 제안된 수직 접합부는 벽체 단부에 서로 다른 방향의 슬롯 때문에 조립이 용이하다. 횡력을 받는 일자형 PC 벽체 시스템을 강성, 강도 그리고 파괴 모드에 대해 기존의 RC 벽체와 비교하였으며, 힘과 처짐과의 관계와 접합부의 조기파괴에 관해 알아보았다. 실험 결과 벽체 단부에 설치된 수직 철근이 먼저 항복하였고, 최종 변형은 접합부의 조기 파괴에 의해 결정되었다. 그리고 벽체에서 효과적인 전단력 전달을 위한 대각선 철근은 그다지 효과적이지 않았다. 단면 해석을 통해 구한 강도와 변형은 실험값과 대체로 일치하였다. 특히, 개폐거동에 의한 변형이 가장 큰 비율을 차지하였다.

Keywords

References

  1. Soudki, K. A., Rizkalla, S. H., and LeBlanc, B., “Horizontal Connections for Precast Concrete Shear Walls subjected to Cyclic Deformations. Part 1 : Mild Steel Connections,” PCI Journal, Vol. 40, No. 4, 1995, pp. 78-97. https://doi.org/10.15554/pcij.07011995.78.96
  2. Soudki, K. A., Rizkalla, S. H., and LeBlanc, B., “Horizontal Connections for Precast Concrete Shear Walls subjected to Cyclic Deformations. Part 2 : Prestressed Connections,” PCI Journal, Vol. 40, No. 5, 1995, pp. 82-96.
  3. Perez, F. J., Pessiki, S., Sause, R., and Lu, L. W., “Lateral Load Tests of Unbonded Post-Tensioned Precast Concrete Walls,” Large Scale-Scale Structural Testing, Edited by Ma. A. Issa, Y. L. Mo, America Concrete Institute, Farmington Hills, Michigan, 2003, pp. 161-183.
  4. Rahman, A. M. and Restrepo, J. I., Earthquake Resistant Precast Concrete Buildings : Seismic Performance of Cantilever Walls Prestressd Using Unbonded Tendons, Civil Engineering Research Report No. 2000-5, University of Canterbury, Christchurch, New Zealand, 2000, 110 pp.
  5. Holden, T. J., A Comparison of the Seismic Performance of Precast Wall Construction : Emulation an Hybrid Approaches, Civil Engineering Research Report No. 2001-4, University of Canterbury, Christchurch, New Zealand, 2001, 145 pp.
  6. 임우영, “C형 접합부를 이용한 프리캐스트 전단벽 시스템에 관한 연구,” 서울대학교 대학원, 석사학위논문, 2006, 125 pp.
  7. Franco, P., Megally, S., and Seible, F., “Seismic Performance of Sacrificial Interior Shear Keys,” ACI Structural Journal, Vol. 100, No. 2, 2003, pp. 177-187.
  8. Annamalai, G. and Brown, R. C., “Shear-Transfer Behavior of Post-Tensioned Grouted Shear-Key Connection in Precast Concrete-Framed Structures,” ACI Structural Journal, Vol. 87, No. 1, 1990. pp. 53-59.
  9. Shaingchin, S., Lukkunaprasit, P., and Wood, S. L., “Influence of Diagonal Web Reinforcement on Cyclic Behaivor of Structural Walls,” Engineering Structures, Vol. 29, No. 4, 2007, pp. 498-510. https://doi.org/10.1016/j.engstruct.2006.05.016
  10. Perez, F. J., Sause, R., and Pessiki, S., “Analytical and Experimental Lateral Load Behavior of Unbonded Posttensioned Precast Concrete Walls,” Journal of Structural Engineering, Vol. 133, No. 11, 2007, pp. 1531-1540. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1531)
  11. MacGregor, J. G. and Wight, J. K., Reinforced Concrete Mechanics and Design, Prentice Hall, Singapore, 2006, pp. 113-114
  12. Panneton, M., Leger, P., and Tremblay, R., “Inelastic Analysis of a Reinforced Concrete Shear Wall Building According to the National Building Code of Canada,” 2005, Canadian Journal of Civil Engineering, 2006, pp. 854-871.
  13. Englekirk, R. E., Seismic Design of Reinforced and Precast Concrete Buildings, John Wiley and Sons, New Jersey, 2003, pp. 348-529.

Cited by

  1. Seismic Performance of T-Shaped PC Walls with Wet Cast Joint vol.26, pp.3, 2014, https://doi.org/10.4334/JKCI.2014.26.3.255