DOI QR코드

DOI QR Code

A Novel Fault Location Scheme on Korean Electric Railway System Using the 9-Conductor Representation

  • Received : 2009.11.30
  • Accepted : 2010.03.27
  • Published : 2010.06.01

Abstract

This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because of long distance, 40[km] or above, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, it must be modeled exactly to analyze the fault current magnitude and fault location. In this paper, suggesting the novel scheme of fault location, a 9-conductor modeling technique including boost wires and impedance bonds is introduced based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and propose a powerful model for fault analysis on electric railway systems.

Keywords

References

  1. Hanmin Lee, Gildong Kim, Sehchan Oh, Gilsoo Jang, Sae-hyuk Kwon, "Fault analysis of Korean AC electric railway system," Electric Power System Research, Vol. 76, Issue 5, pp. 317-326, Mar. 2006 https://doi.org/10.1016/j.epsr.2005.08.001
  2. J. Kim, Power System and Protection Scheme on Electric Railway System, Vol. 1, Kidari, Korea, 2004, p. 262.
  3. Hanmin Lee, Kwanghae Oh, Changmu Lee, Sanghoon Chang, Gilsoo Jang, Saehyuk Kwon, "A Reduced Equivalent 5-Conductor Modeling of the Catenary Systme," The Transaction of the KIEE, Vol. 52-A, No. 12, pp. 684-690, Dec. 2003
  4. Hanmin Lee, Kwanghae Oh, Changmu Lee, Hyunjune Park, Gilsoo Jang, Saehyuk Kwon, "A Reduced Equivalent Line Constant of the Catenary System," The Transaction of the KIEE, Vol. 53-A, No. 8, pp. 421-431, Aug. 2004
  5. B. Yang, Advanced Electric Railway Engineering, vol. 1, Sungandang, Korea, 2003, p. 230, p.319
  6. P. Wilson, PSCAD User's Guide, HVDC Research Centre, Canada, 2003
  7. Z. Xu, M. Liu, G. Yang, and N. Li, "Application of interval analysis and evidence and evidence theory to fault location," IET Electric Power Applications, Vol. 3, Issue1, pp. 77-84, Jan. 2009 https://doi.org/10.1049/iet-epa:20070439
  8. Chih-Ju Chou, Ying-Tung Hsiao, Jhane-Li Wang, Yaw-Tzong Hwang, "Distribution of earth leakage currents in railway systems with drain autotransformer," IEEE Trans. Power Delivery, Vol. 16, Issue 2, pp. 271-275, Apr. 2001 https://doi.org/10.1109/61.915494