Abstract
This study was investigated to complement nitrogen removal of low concentration influent municipal sewage. The following are the results of the effect of Internal Recircularion and Step Feed rates on Treatment efficiency at a BOD low concentration influent municipal sewage. Up to 90.0% of BOD, 87.8% of COD, 71.0% of T-N, 75.3% of T-P were removed on average at a low concentration influent. Whereas BOD and T-P were removed without any relations to Step Feed rates, T-N was influenced. Nitrogen removal efficiencies in 80% of Step Feed rates was 65%, which was caused by the lack of Carbon Source for denitrification. Nitrogen removal efficiency in 40% of Step Feed rates was 58%, which means it was not removed but dischared. Consequently, the efficiency was 73%, 80%, and 78% in 70%, 60% and 50% of Step Feed rates, which was concluded as the best range of Step Feed rates. Nitrogen removal efficiency increased under the condition of Internal Recircularion. At over 150% of Internal Recircularion rate, the efficiencies were not affected any more. It is believed that lots of Recircularion caused inflow of DO to anoxic tank. Therefore, the most appropriate Internal Recircularion rate can be concluded as 50~150%.
본 연구에서는 저농도로 유입되어 정상적인 운영이 되지 않고, 질소제거가 어려운 소규모 하수처리시설의 문제점을 해결하기 위하여 5Stage로 구성된 하수고도처리 공정의 저농도 유입성상에서 최적의 단계유입비와 내부순환비를 결정하기 위해 Lab-Scale 모형실험장치를 제작하여 실험하였다. 저농도의 유입조건에서 효율적인 고도처리를 위해 내부순환과 단계유입이 공정성능에 미치는 영향을 평가한 결과는 다음과 같다. 첫째, 분석항목별 처리효율은 BOD 90.0%, COD 87.8%, T-N 71.0%, T-P 75.3%로 나타났으며, T-N은 단계유입에 따라 처리효율의 변동이 있는 것으로 나타났다. 둘째, 혐기조로 유입되는 단계유입비 70, 60, 50%에서는 각각 73, 80, 78%로 나타나 최적의 단계 유입비 범위로 판단되었다. 셋째, 질소제거를 위해 내부순환을 할 경우 내부순환을 하지않는 경우보다 질소 제거효율이 증가됨을 알 수 있었고, 내부순환비가 150%이상에서는 더 이상 처리효율에 영향을 미치지 못하는 것으로 나타났다. 이는 다량의 순환으로 인해 무산소조에 DO의 유입으로 인한 것으로 판단된다. 따라서 내부순환비는 50~150%가 적정한 것으로 판단되었다.