Design for Improving Magnetic Force of Control Valve in Variable Compressor

가변압축기용 제어 밸브의 전자력 향상 설계

  • Received : 2010.10.14
  • Accepted : 2010.11.22
  • Published : 2010.12.01

Abstract

This paper represents solenoid design of control valve for incline angle control in variable compressor. Some theoretical and numerical analysis were performed to analyse solenoid and compared with experimental results. Maxwell program was used for numerical analysis. Through redesigns of housing body, plunger, core, and disk in control valve, the needed force was gotten. Reduction of core groove and housing body air-gap had a large influence on magnetic force. But increasing of disk thickness had little effect on magnetic force. Control valve efficiency could be improved through solenoid redesign.

Keywords

References

  1. 이기수, 성현진, 허형석, 이현우 "다단 자동변속기용 유압 비례제어 솔레노이드 밸브의 CFD 해석", 한국자동차공학회 춘계학술대회논문, 2009
  2. 윤소남, 함영복 "배기 브레이크용 솔레노이드 밸브의 특성 해석", 한국자동차공학회논문집 제12권, 제 1호, pp 190-195, 2004
  3. 윤소남, 함영복, 박중호, 윤동원, 허덕열, "연료전지용 솔레노이드 밸브의 정특성", 유공압시스템학회추계학술대회논문, 2010
  4. 송창섭 ,"전자식 유압 비례 복합 밸브에 관한 연구 ", KAIS 박사학위논문, pp. 1-21, 1980.
  5. 이대길, "비례복합밸브내의 솔레노이드의 특성에 관한 연구", KAIS 석사학위논문, pp. 1-70, 1977.
  6. Herbert C. Roters, "Electro magnetic devices", John Wiley & Sons, New York, pp. 196-335, 1941.
  7. 이태형, "ISC 밸브용 테이퍼 플런저형 비례전자석에 관한 연구", 한양대학교 석사학위논문, pp 2-13, 1992