References
- J. S. Lai and F. Z. Peng, "Mutilevel converters – A new breed of power converters," IEEE Trans. Ind. Appl., Vol. 32, No. 3, pp. 509–517, May/Jun. 1996. https://doi.org/10.1109/28.502161
- M. Massoud, S. J. Finney, and B. W. Williams, "High-power, highvoltage IGBT applications: series connection of IGBTs or multilevel converters?," INT. J. ELECTRONICS, Vol. 90, No. 11–12, pp. 763–778, 2003. https://doi.org/10.1080/00207210310001666429
- Han, B. Bae, S. Baek, and G. Jang, "New Configuration of UPQC for Medium-Voltage Application," IEEE Trans. Power Delivery, Vol. 21, No. 3, pp. 1438-1444, Jul. 2006. https://doi.org/10.1109/TPWRD.2005.860235
- M. F. Escalante, "Cascaded H-Bridge Multilevel Active Compensator," in IEEE Int. Power Electronics Congress, Puebla, Mexico, pp. 1 – 6, Oct. 2006.
- J. Rodriguez, J. S. Lai, and F. Z. Peng, "Multilevel inverters: a survey of topologies, control, and applications," IEEE Trans. Industrial Electronics, Vol. 49, Issue 4, pp. 724 – 738, Aug. 2002. https://doi.org/10.1109/TIE.2002.801052
- Cecati, A. Dell, M. Liserre, and V. G. Monopoli, "Design of H-Bridge Multilevel Active Rectifier for Traction Systems," IEEE Trans. Industry Applications, Vol. 39, No. 5, pp. 1541 – 1550, Set.-Oct. 2003. https://doi.org/10.1109/TIA.2003.816515
- G. Brando, A. Dannier, and A. Del Pizzo, "An Optimized Control Technique of Cascaded H-bridge Multilevel Active Front-ends," in IEEE Int. Power Electronics and Motion Control Conf., EPE-PEMC 2006, Portoroz , Slovenia , pp. 793 – 799, Aug. 2006.
- G. Sinha, C. Hochgraf, R. H. Lasseter, D. M. Divan, and T. A. Lipo, "Fault protection in a multilevel inverter implementation of a static condenser," IEEE IAS Annual Meeting, Conf., pp. 2557-2564, 1995.
- C. Turpin, P. Baudesson, F. Richardeau, F. Forest, and T. A. Meynard, "Fault management of multicell converters," IEEE Trans. Ind. Electron., Vol. 49, pp. 988-997, Oct. 2002. https://doi.org/10.1109/TIE.2002.803196
- J. Rodriguez, P. W. Hammond, J. Pontt, R. Musalem, P. Lezana, and M. J. Escobar, "Operation of a medium-voltage drive under faulty conditions," IEEE Trans. Industry Electronics, Vol. 52, pp. 1080-1085, 2005. https://doi.org/10.1109/TIE.2005.851645
- S.Wei, B.Wu, F. Li, and X. Sun, "Control method for cascaded H-bridge multilevel inverter with faulty power cells," in Proc. IEEE Applied Power Electronics Conf., Miami, FL, Vol. 1, pp. 261-267, Feb. 2003.
- H. Iman-Eini, J-L. Schanen, Sh. Farhangi, and J. Roudet, "A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers," IEEE transaction on Power Electronics, Vol. 23, No.5, pp. 2428-2442, Sep. 2008. https://doi.org/10.1109/TPEL.2008.2002055
- S. Khomfoit, and L. M. Tolbert, "Fault detection and reconfiguration technique for cascaded H-bridge 11-level inverter drives operating under faulty condition," in Proc. Power Electronics and Drive Systems, PEDS'07,pp. 1035–1042, Nov. 2007.
- B. Badrzadeh, K. S. Smith, and R. C. Wilson, "Alternatives for highpower power electronic converters, switching devices and electric machines for very large wind farms: A technological and market assessment," European Wind Energy Conference, 2009.
- S. Gunturi and D. Schneider, "On the Operation of a Press Pack IGBT Module Under Short Circuit Conditions," IEEE transaction on Advanced Packaging, vol. 29, no. 3, pp. 433-440, Aug. 2006. https://doi.org/10.1109/TADVP.2006.875090
- R. Schlegel, E. Herr, and F. Richter, "Reliability of non-Hermetic pressure contact IGBT modules," Microelectron. Rel., vol. 41, pp.1689–1694, Oct. 2001. https://doi.org/10.1016/S0026-2714(01)00193-7
- W. Song and A.Q. Huang, "Control strategy for fault-tolerant cascaded multilevel converter based STATCOM," in Proc. Applied Power Electronics Conference, APEC 2007, pp. 1073 – 1076, Feb. /Mar. 2007.
- V. John, B.-S. Suh, and T.A. Lipo, "Fast clamped short circuit protection of IGBTs," IEEE-IAS Transactions on Industry Applications, Vol. 35, No. 2, pp. 477-486, Mar./Apr. 1999. https://doi.org/10.1109/28.753644
- F. Huang, and F. Flett, "IGBT fault protection based on di/dt feedback control" in Proc. IEEE PESC conf., pp. 1478-1484, Jun. 2007.
Cited by
- Analysis of the Internal Electrical Characteristics of Electronic Power Transformers vol.13, pp.5, 2013, https://doi.org/10.6113/JPE.2013.13.5.746
- Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems vol.10, pp.5, 2010, https://doi.org/10.6113/JPE.2010.10.5.572
- Fault-Tolerant Operation of Three-Phase Cascaded H-Bridge Converters Using an Auxiliary Module vol.64, pp.2, 2017, https://doi.org/10.1109/TIE.2016.2613983
- A New Single-Phase Asymmetrical Cascaded Multilevel DC-Link Inverter vol.16, pp.4, 2016, https://doi.org/10.6113/JPE.2016.16.4.1504
- Single-Stage Double-Buck Topologies with High Power Factor vol.11, pp.5, 2011, https://doi.org/10.6113/JPE.2011.11.5.655
- Modified space vector modulation for fault-tolerant operation of multilevel cascaded H-bridge inverters vol.6, pp.4, 2013, https://doi.org/10.1049/iet-pel.2012.0543
- Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization vol.14, pp.5, 2014, https://doi.org/10.6113/JPE.2014.14.5.946