참고문헌
- Fact sheet for obesity and cardiovascular disease: A report from the American Heart Association, 2009.
- D. Jabaudon, et.al, “Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack,” Stroke, J.Amer. Heart Assoc., Vol.35, pp.1647-1651, May, 2004.
- E.Rodriguez-Cruz, Hypertension : Overview-eMedicine. Available : http://emedicine.medscape.com/article/889877-overview
- Task Force of the Eourpean Society of Cardiology and the North American Society of Pacing and Electrophysiology, “Heart Rate Variability: Standards of Measurement,” Physiological Interpretation, and Clinical Use, 93 1996.
- C.Jing, et al, “The Research on Emotion Recognition from ECG Signal,” International Conference on Information Technology and Computer Science, pp. 497-500, 2009.
- A.Haag, et al, “Emotion Recognition Using Bio-Sensors: First Steps Towards an Automatic System,” Proceedings of the Kloster Irsee Tutorial and Research workshop on Affective Dialogue Systems, pp.36-48, 2004.
- Rigas, et.al, “A User Independent, Biosignal Based, Emotion Recognition Method,” Lecture notes in Computer Science, No.4511, pp.314-318, 2007 https://doi.org/10.1007/978-3-540-73078-1_36
- J. Yoo, et.al, “A Wearable ECG Acquisition System With Compact Planar-Fashionable Circuit Board- Based Shirt,” IEEE Transactions on Information Technology in Biomedicine, Vol.13, pp.892-902, 2009. https://doi.org/10.1109/TITB.2009.2033053
- A. C-W. Wong, et al, “A 1V Micropower Systemon-Chip for Vital-Sign Monitoring in Wireless Body Sensor Networks,” ISSCC Dig. Tech. Papers, pp.138-139, Feb., 2008.
- E.M. Spinelli, et.al, “A Transconductance Driven-Right-Leg Circuit,” IEEE Transactions on Biomedical Engineering, Vol.47, pp.1466-1470, 1999. https://doi.org/10.1109/10.804574
- S.N. Pocock, “Earth-free patient monitoring, Part 1: principles, practice and hazards,” Biomed. Eng., Vol.7, pp.21-25, 1972.
- E.M. Spinelli, et.al, “Two-Electrode biopotential measurements: Power line interfere Analysis,” IEEE Transaction on biomedical engineering, Vol. 52, pp.1436-442, Aug. 2005. https://doi.org/10.1109/TBME.2005.851488
- D.E.Wood, et.al, “Comparative analysis of powr line interference between two-or three-electrode biopotential amplifiers,” Medical & Biological Engineering & Computing, Vol.33, pp.63-68, 1995. https://doi.org/10.1007/BF02522948
- N.V. Thakor, et.al, “Ground-free ECG Recording with Two Electrodes,” IEEE Transaction on biomedical engineering, Vol.BME-27, pp.699-704, Dec. 1980. https://doi.org/10.1109/TBME.1980.326595
- K. Hachisuka, et al, “Development and performance analysis of an intra-body communication device,” in Int. Solid-State Sens., Actuators, Microsyst. Conf., pp.1722-1725, 2003.
- George E. Bergey, et al, “Electrocardiogram recording with pasteless electrodes,” IEEE Trans. on Bio-medical Engineering, Vol.18, pp.206-211,1971. https://doi.org/10.1109/TBME.1971.4502833
- Long Yan, et al, “A Two-Electrode 2.88nJ/Conv. Biopotential Acquisition System for Portable Healthcare Device,” Proc. Of the IEEE Asian Solide-State Circuit Conference (A-SSCC), pp.329- 332, Nov., 2008.
-
K.N.Leung and P.K.T.Mok, “A CMOS Voltage Reference based pm weighted
${\Delta}V_{GS}$ for CMOS Low-Dropout Linear Regulators,” IEEE Journal of Solid-State Circuits, Vol.38, pp.146-150, Jan., 2003. https://doi.org/10.1109/JSSC.2002.806265 - Refet Firat Yazicioglu, Chris Van Hoff, et.al, “A 60 uW 60 nV/srtHz Redout Front-End for Portable Biopotential Acquisition Systems,” IEEE Journal of Solid-State Circuits, Vol.42, pp.1100-1109, May., 2007. https://doi.org/10.1109/JSSC.2007.894804
- Christian C. ENZ and Gabor C. Temes, “Circuit Techniques for Reducing the Effects of Op-Amp Imperfections: Autozeroing, Correlated Double Sampling, and Chopper Stablization,” Proc. IEEE, Vol.84, pp.1584-1614, Nov., 1996. https://doi.org/10.1109/5.542410
- Datasheet of INA321, Simplified ECG Circuit for Medical Applications. Available : http://focus.ti.com/lit/ds/sbos168d/sbos168d.pdf
피인용 문헌
- A Digital-Domain Calibration of Split-Capacitor DAC for a Differential SAR ADC Without Additional Analog Circuits vol.60, pp.11, 2013, https://doi.org/10.1109/TCSI.2013.2252475
- Low-Power Wearable ECG Monitoring System for Multiple-Patient Remote Monitoring vol.16, pp.13, 2016, https://doi.org/10.1109/JSEN.2016.2564995
- A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function vol.39, pp.4, 2016, https://doi.org/10.1007/s13246-016-0483-5
- A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric vol.50, pp.2, 2013, https://doi.org/10.5573/ieek.2013.50.2.210
- Fashionable wrist band using highly conductive fabric for electrocardiogram signal monitoring pp.1530-8057, 2018, https://doi.org/10.1177/1528083718779427