특수 차량용 정용량 피스톤 펌프의 개발에 관한 연구

The Study on Development of Fixed Displacement Piston Pump for Special Access Vehicle

  • 박정호 (창원전문대학 기계설계과) ;
  • 김문경 (창원전문대학 기계설계과) ;
  • 최석창 (창원전문대학 기계설계과)
  • 투고 : 2010.03.25
  • 심사 : 2010.05.13
  • 발행 : 2010.06.30

초록

Cylinder block is driven by tapered piston for bent-axis type piston pump, so that geometrical mechanism is very complicate. Piston rod must have not separated from shaft when shaft and piston rod is assembled. For this reason, shaft design is changed. Finite element analysis is performed for analyzed structural stability and flexible dynamic behavior. The result of the analysis, maximum equivalent stress occurred under yield stress, therefore structural stability is satisfactory. and flexible dynamic analysis give useful information about driving gear. These background data is avail of manufacture of piston pump.

키워드

참고문헌

  1. Jung, J. Y, Baek, I. H, Cbo, I. S, Song, K. K, Oh, S. H and Jeong, Y. W. "A Study on Driving Range of Cylinder Block to Eccentricity Ratio of Disk in Vent Axis Type Oil Hydraulic Piston Pump" 유공압시스템학회, Vol. 5-2, pp 1-7. 2008
  2. Yoon, S. R., "Structural Analysis and Measurement of Turbopump Casings" 항공우주기술, Vol. 5-2, pp 174-180. 2006
  3. Lee, G. S. "A Stufy on GUI Development of Structural Analysis of LNG Pump Tower" 한국전산구조공학회논문집, Vol. 20-5, pp 605-613, 2007
  4. Pham, M. Y, Phan, P. V, Han, C. H, and Ku, N. S., "Three Dimensional Electro-Fluid-Structural Inter-action Simulation for Pumping Performance Evaluation of a Valveless Micropump'' 한국전산구조공학회지, Vol. 37, pp.744-750, 2009
  5. Seo, Y. S. "Structural Integrity Analysis an Horizontal Nuclear Power Pump'' 유체기계공업학회, 2005년도 연구개발 발표회 논문집, pp.315-329, 2005