Experimental Study on Fire Resistant Capacity and Thermal Conduction of Construction Material Using the Circulation Resources

폐콘크리트 순환자원을 이용한 건설재료의 화재내력 및 단열성에 관한 실험적 연구

  • Choi, Jea-Nam (Graduate School of Energy and Environment, Seoul National University of Science and Technology) ;
  • Hong, Se-Hwa (Dept. of Safety Engineering Seoul National University of Science and Technology) ;
  • Son, Ki-Sang (Dept. of Safety Engineering Seoul National University of Science and Technology)
  • 최재남 (서울과학기술대학교 에너지환경대학원) ;
  • 홍세화 (서울과학기술대학교 안전공학과) ;
  • 손기상 (서울과학기술대학교 안전공학과)
  • Received : 2010.07.07
  • Accepted : 2010.09.09
  • Published : 2010.09.30

Abstract

This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.

Keywords

References

  1. A. M. Neville, "Resistance of Concrete to Fire and Influence of Temperature on Strength", Pro perties of Concrete, pp. 498-506, 1982.
  2. B. Georgali, P. E. Tsakiridis, "Microstructure of fire-damaged concrete: A case study", Cement & Concrete Composites, Vol. 27, pp. 255-259, 2004.
  3. Z. P. Bazant, M. F. Kaplan, "Concrete at high temperature: Material properties and mathematical models, Longman, U.K., 1996.
  4. 대한건축사협회, "에너지 절약형 건출설계 핸드북(주택편)", 대한건축사협회, 1990.
  5. 손기상, "폐타이어 콘크리트 화재 특성에 관한 실험적 연구", 한국화재소방학회지 제16권 제1호, pp. 22-26, 2002.
  6. 이승환, 최익창, 한상국, "재생미분말의 유해성 분석및 재생미분말을 혼입한 콘크리트의 특성", 해양환경안전학회, 제14권, 제4호, pp. 289-295, 2008.
  7. 이완조, "고강도용 폴리카르본산계 고성능 감수제가사용된 콘크리트의 성능", 한국세라믹학회, 제42권,제3호, pp. 182-187, 2005.
  8. 이정구, "폐콘크리트 슬러지를 사용한 밀도 조절형경량블록 개발에 관한 기초적 연구", 공주대학교 대학원, 2008.
  9. 이중원, "고온을 받은 콘크리트의 특성변화 및 손상도 평가에 관한 연구", 연세대학교, 2009.
  10. 정국환, "팽창점토골재를 사용한 경량골재콘크리트의열전도율에 관한 실험적 연구", 연세대학교, 1993.
  11. 정상진, 이영도, "고온하에서의 콘크리트 성상변화",콘크리트학회지, 제9권 제4호, pp. 25-30, 1997.
  12. 조병헌, 손기상, "종이 혼합 콘크리트의 내화특성실험연구", 대한안전경영과학회, 제9권 제4호, pp.83-90, 2007.
  13. 최롱, "폐콘크리트 재생미분의 재활용기술 개발 방향과 시멘트-콘크리트의 자원순환체제 구축을 위한 정책 제언", 한국과학기술정보연구원, 2004.
  14. 홍세화, 손기상, 최재남, "폐콘크리트 순환자원을이용한 건설재료의 특성연구", 한국안전학회, 제25권, 제2호, 2010.